Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 rbnEnvMonMIB 1.3.6.1.4.1.2352.2.4
The MIB used to genericially manage Environmental Monitor functionality on RedBack Networks devices.
     rbnEnvMonMIBNotifications 1.3.6.1.4.1.2352.2.4.0
         rbnFanFailChange 1.3.6.1.4.1.2352.2.4.0.1
A rbnFanFailChange notification signifies that the value of an instance of rbnFanFail has changed.
         rbnPowerFailChange 1.3.6.1.4.1.2352.2.4.0.2
A rbnPowerFailChange notification signifies that the value of an instance of rbnPowerFail has changed
     rbnEnvMonMIBObjects 1.3.6.1.4.1.2352.2.4.1
         rbnFanStatusTable 1.3.6.1.4.1.2352.2.4.1.1 no-access
This table contains one row per fan test point. Note that there is not necessarily a one-to-one relationship between fan test points and fan assemblies; a single test point may be used to monitor the status of multiple fans.
             rbnFanStatusEntry 1.3.6.1.4.1.2352.2.4.1.1.1 no-access
Information about a particular fan test point
                 rbnFanIndex 1.3.6.1.4.1.2352.2.4.1.1.1.1 integer32 no-access
The index of a fan test point.
                 rbnFanDescr 1.3.6.1.4.1.2352.2.4.1.1.1.2 displaystring read-only
The description of a fan test point. If an instance of this object is associated with a single fan assembly, then the value of this object should be the same as the name by which the assembly is normally referenced. If an instance is associated with multiple fan assemblies, then the value of this object should contain the names of all of the fan assemblies being monitored.
                 rbnFanFail 1.3.6.1.4.1.2352.2.4.1.1.1.3 truthvalue read-only
The status of a fan test point. If an instance of this object has the value true, then a fan monitored by the test point has failed. If an instance of this object has the value false, then the fan (or fans) monitored by the test point are operational.
         rbnPowerStatusTable 1.3.6.1.4.1.2352.2.4.1.2 no-access
This table contains one row per power test point. Note that there is not necessarily a one-to-one relationship between power test points and power supply assemblies; a single test point may be used to monitor the status of multiple power supplies.
             rbnPowerStatusEntry 1.3.6.1.4.1.2352.2.4.1.2.1 no-access
Information about a particular power test point
                 rbnPowerIndex 1.3.6.1.4.1.2352.2.4.1.2.1.1 integer32 no-access
The index of a power test point.
                 rbnPowerDescr 1.3.6.1.4.1.2352.2.4.1.2.1.2 displaystring read-only
The description of a power supply test point. If an instance of this object is associated with a single power supply assembly, then the value of this object should be the same as the name by which the assembly is normally referenced. If an instance is associated with multiple power supply assemblies, then the value of this object should contain the names of all of the power supply assemblies being monitored.
                 rbnPowerFail 1.3.6.1.4.1.2352.2.4.1.2.1.3 truthvalue read-only
The status of a power test point. If an instance of this object has the value true, then a power supply monitored by the test point has failed. If an instance of this object has the value false, then the power supply (or supplies) monitored by the test point are operational.
     rbnEnvMonMIBConformance 1.3.6.1.4.1.2352.2.4.2
         rbnEnvMonMIBGroups 1.3.6.1.4.1.2352.2.4.2.1
             rbnEnvMonMIBObjectGroup 1.3.6.1.4.1.2352.2.4.2.1.1
A collection of objects providing environmental monitor information.
             rbnEnvMonMIBNotificationGroup 1.3.6.1.4.1.2352.2.4.2.1.2
A collection of notifications providing environmental monitor information.
         rbnEnvMonMIBCompliances 1.3.6.1.4.1.2352.2.4.2.2
             rbnEnvMonMIBCompliance 1.3.6.1.4.1.2352.2.4.2.2.1
The compliance statement for the EnvMon MIB