Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 chrComIfifTableTable 1.3.6.1.4.1.3695.1.2.10 no-access
Chromatis Interface Table
       chrComIfifTableEntry 1.3.6.1.4.1.3695.1.2.10.1 no-access
           chrComIfifIndex 1.3.6.1.4.1.3695.1.2.10.1.1 unsigned32 read-only
1.Index referring to the equipment table (Shelf, Slot) (9 bits) 2. Index containing MPHY port number in card. For OC3 trib 0-3 For TC&ATM Ifs we also have: SAR if. = SAR_FIFO_IF (FE) APS FIFO = ASP_FIFO_IF (FF) Note that these new interfaces have no low layers bellow, i.e. there are no SONET layers on these virtual supports (6 bits). 3. Index containing sub-port number, e.g., 0-3 OC12s in OC48 frame (6 bits). 4. (2^6-1)-Null (all bits are 1) reserved for NULL interface, NullVCPeerID, etc. 1-OTSSRC Optical Transmission Section Source (OPA,ADOM,OMDM) 2-OTS-SNK Optical Transmission Section Sink. (OPA,ADOM,OMDM) 3-OMS-SRC Optical Multiplex Section Source (ADOM, OMDM) 4-OMS-SNK Optical Multiplex Section Sink (ADOM, OMDM) 5-OCH Optical Channel (OCM/Trib) 6-SNT-S Sonet Section (OCM/Trib) 7-SNT-L Sonet Line (OCM/Trib) 8-SNT-P Sonet Path (OCM/Trib) 9-TC&ATM C and ATM general cell layer (OCM/Trib) 10-Ethernet 11-IP 12-Synchronization (6 bits) 5. Virtual interface represent a whole protection peer, out of which some members are working and the rest are protecting. SAR and Egress FIFO are real interfaces (5 bits).
           chrComIfifName 1.3.6.1.4.1.3695.1.2.10.1.2 displaystring read-write
String of text defining the name of the port given by the user.
           chrComIfifAdminStatus 1.3.6.1.4.1.3695.1.2.10.1.3 adminstatus read-write
The desired state of the interface. The testing(3) state indicates that no operational packets can be passed. When a managed system initializes, all interfaces start with ifAdminStatus in the down(2)state. As a result of either explicit management action or per configuration information retained by the managed system, ifAdminStatus is then changed to either the up(1) or testing(3) states (or remains in the down(2) state).
           chrComIfifOperStatus 1.3.6.1.4.1.3695.1.2.10.1.4 operstatus read-only
The down state of ifOperStatus has two meanings, depending on the value of ifAdminStatus. (1) if ifAdminStatus is not down and ifOperStatus is down then a fault condition is presumed to exist on the interface. 2) if ifAdminStatus is down, then ifOperStatus will normally also be down (or notPresent) i.e.,there is not (necessarily) a fault condition on the interface.
           chrComIfvirtualIfIndex 1.3.6.1.4.1.3695.1.2.10.1.5 unsigned32 read-only
This attribute is an outcome of the card/Path Protection attribute of the equipment table. The peer ID is a virtual card ID (which is the higher of the two peers). Note that we do not reflect peering of VSP (real path protection) in this field!
           chrComIfreal1IfIndex 1.3.6.1.4.1.3695.1.2.10.1.6 unsigned32 read-only
This field represents the first real IfIndex , if IfIndex is virtual.
           chrComIfreal2IfIndex 1.3.6.1.4.1.3695.1.2.10.1.7 unsigned32 read-only
This field represents the second real IfIndex , if IfIndex is virtual.