BROCADE-SYSTEM-MIB: View SNMP OID List / Download MIB

VENDOR: BROCADE


 Home MIB: BROCADE-SYSTEM-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 swTrapsV2 1.3.6.1.4.1.1588.2.1.1.1.0
The Traps for Brocade's Switch.
     swFCPortScn 1.3.6.1.4.1.1588.2.1.1.1.0.3
This trap is sent whenever an FC port operational status or its type changed. The events that trigger this trap are port goes to online/offline, port type changed to E-port/F-port/FL-port. swFCPortName and swSsn are optional varbind in the trap PDU.swSsn is optional varbind sent when swExtTrap is also enabled.swVfId is optional if VF is enabled.
     swEventTrap 1.3.6.1.4.1.1588.2.1.1.1.0.4
This trap is generated when an event whose level at or below swEventTrapLevel occurs.
     swStateChangeTrap 1.3.6.1.4.1.1588.2.1.1.1.0.12
This trap is sent whenever switch state changes to online/offline
 swSystem 1.3.6.1.4.1.1588.2.1.1.1.1
The MIB module is for system information. Copyright (c) 1996-2003 Brocade Communications Systems, Inc. All rights reserved.
     swCurrentDate 1.3.6.1.4.1.1588.2.1.1.1.1.1 displaystring read-only
The current date information in displayable textual format.
     swBootDate 1.3.6.1.4.1.1588.2.1.1.1.1.2 displaystring read-only
The date and time when the system last booted, in displayable textual format.
     swFWLastUpdated 1.3.6.1.4.1.1588.2.1.1.1.1.3 displaystring read-only
The information indicates the date when the firmware was last updated, in displayable textual format.
     swFlashLastUpdated 1.3.6.1.4.1.1588.2.1.1.1.1.4 displaystring read-only
The information indicates the date when the FLASH was last updated, in displayable textual format.
     swBootPromLastUpdated 1.3.6.1.4.1.1588.2.1.1.1.1.5 displaystring read-only
The information indicates the date when the boot PROM was last updated, in displayable textual format.
     swFirmwareVersion 1.3.6.1.4.1.1588.2.1.1.1.1.6 displaystring read-only
The current version of the firwmare.
     swOperStatus 1.3.6.1.4.1.1588.2.1.1.1.1.7 integer read-only
The current operational status of the switch. The states are as follow: o online(1) means the switch is accessible by an external port; o offline(2) means the switch is not accessible; o testing(3) means the switch is in a built-in test mode and is not accessible by an external port; o faulty(4) means the switch is not operational. Enumeration: 'offline': 2, 'testing': 3, 'faulty': 4, 'online': 1.
     swSsn 1.3.6.1.4.1.1588.2.1.1.1.1.10 displaystring read-only
The soft serial number of the switch.
     swFlashDLOperStatus 1.3.6.1.4.1.1588.2.1.1.1.1.11 integer read-only
The operational status of the FLASH. The operational states are as follow: o swCurrent(1) indicates that the FLASH contains the current firmware image or config file; o swFwUpgraded(2) state indicates that it contains the image upgraded from the swFlashDLHost.0.; o swCfUploaded(3) state indicates that the switch configuration file has been uploaded to the host; and o swCfDownloaded(4) state indicates that the switch configuration file has been downloaded from the host. o swFwCorrupted (5) state indicates that the firmware in the FLASH of the switch is corrupted. Enumeration: 'swFwCorrupted': 5, 'swCfUploaded': 3, 'unknown': 0, 'swCurrent': 1, 'swCfDownloaded': 4, 'swFwUpgraded': 2.
     swFlashDLAdmStatus 1.3.6.1.4.1.1588.2.1.1.1.1.12 integer read-only
The state of the FLASH. o swCurrent(1) indicates that the FLASH contains the current firmware image or config file; o swFwUpgrade(2) means that the firmware in the FLASH is to be upgraded from the host specified; o swCfUpload(3) means that the switch config file is to be uploaded to the host specified; or o swCfDownload(4) means that the switch config file is to be downloaded from the host specified. o swFwCorrupted(5) state indicates that the firmware in the FLASH is corrupted. This value is for informational purpose only. However, set of swFlashDLAdmStatus to this value is not allowed. The host is specified in swFlashDLHost.0. In addition, user name is specified in swFlashDLUser.0, and the file name specified in swFlashDLFile.0. Reference the user manual on the following commands, o firmwareDownload, o configUpload, and o configDownload. Enumeration: 'swCurrent': 1, 'swFwCorrupted': 5, 'swFwUpgrade': 2, 'swCfUpload': 3, 'swCfDownload': 4.
     swBeaconOperStatus 1.3.6.1.4.1.1588.2.1.1.1.1.18 integer read-only
The current operational status of the switch beacon. When the beacon is on, the LEDs on the front panel of the switch run alternately from left to right and right to left. The color is yellow. When the beacon is off, each LED will be in their its regular status indicating color and state. Enumeration: 'on': 1, 'off': 2.
     swBeaconAdmStatus 1.3.6.1.4.1.1588.2.1.1.1.1.19 integer read-only
The desired status of the switch beacon. When the beacon is set to on, the LEDs on the front panel of the switch run alternately from left to right and right to left. The color is yellow. When the beacon is set to off, each LED will be in its regular status indicating color and state. Enumeration: 'on': 1, 'off': 2.
     swDiagResult 1.3.6.1.4.1.1588.2.1.1.1.1.20 integer read-only
The result of the power-on startup (POST) diagnostics. Enumeration: 'sw-ok': 1, 'sw-embedded-port-fault': 3, 'sw-faulty': 2.
     swNumSensors 1.3.6.1.4.1.1588.2.1.1.1.1.21 integer32 read-only
The number of sensors inside the switch.
     swSensorTable 1.3.6.1.4.1.1588.2.1.1.1.1.22 no-access
The table of sensor entries.
           swSensorEntry 1.3.6.1.4.1.1588.2.1.1.1.1.22.1 no-access
An entry of the sensor information.
               swSensorIndex 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.1 swsensorindex read-only
This object identifies the sensor.
               swSensorType 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2 integer read-only
This object identifies the sensor type. Enumeration: 'power-supply': 3, 'fan': 2, 'temperature': 1.
               swSensorStatus 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3 integer read-only
The current status of the sensor. Enumeration: 'absent': 6, 'below-min': 3, 'above-max': 5, 'unknown': 1, 'nominal': 4, 'faulty': 2.
               swSensorValue 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4 integer32 read-only
The current value (reading) of the sensor. The value, -2147483648, represents an unknown quantity. It also means that the sensor does not have the capability to measure the actual value. In V2.0, the temperature sensor value will be in Celsius; the fan value will be in RPM (revolution per minute); and the power supply sensor reading will be unknown.
               swSensorInfo 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5 displaystring read-only
Additional displayable information on the sensor. In V2.x, it contains the sensor type and number in textual format. For example, 'Temp 3', 'Fan 6'.
     swID 1.3.6.1.4.1.1588.2.1.1.1.1.24 integer32 read-only
The number of the logical switch (0/1).
     swEtherIPAddress 1.3.6.1.4.1.1588.2.1.1.1.1.25 ipaddress read-only
The IP Address of the Ethernet interface of this logical switch.
     swEtherIPMask 1.3.6.1.4.1.1588.2.1.1.1.1.26 ipaddress read-only
The IP Mask of the Ethernet interface of this logical switch.
     swIPv6Address 1.3.6.1.4.1.1588.2.1.1.1.1.29 displaystring no-access
IPV6 address.
     swIPv6Status 1.3.6.1.4.1.1588.2.1.1.1.1.30 integer no-access
The current status of ipv6 address. Enumeration: 'inactive': 4, 'ipdeprecated': 3, 'preferred': 2, 'tentative': 1.
 swFabric 1.3.6.1.4.1.1588.2.1.1.1.2
The OID sub-tree for swFabric group.
     swVfId 1.3.6.1.4.1.1588.2.1.1.1.2.15 integer32 read-only
The Virtual fabric id.
 swFCport 1.3.6.1.4.1.1588.2.1.1.1.6
The OID sub-tree for swFCport group.
     swFCPortTable 1.3.6.1.4.1.1588.2.1.1.1.6.2 no-access
A table that contains, one entry for each switch port, configuration and service parameters of the port.
         swFCPortEntry 1.3.6.1.4.1.1588.2.1.1.1.6.2.1 no-access
An entry containing the configuration and service parameters of the switch port.
             swFCPortIndex 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.1 swportindex read-only
This object identifies the switch port index. Note that the value of a port index is 1 higher than the port number labeled on the front panel. E.g. port index 1 correspond to port number 0.
             swFCPortType 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.2 integer read-only
This object identifies the type of switch port. It may be of type stitch(1), flannel(2), loom(3) , bloom(4),rdbloom(5) or wormhole(6). Enumeration: 'loom': 3, 'stitch': 1, 'wormhole': 6, 'bloom': 4, 'other': 7, 'unknown': 8, 'rdbloom': 5, 'flannel': 2.
             swFCPortPhyState 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.3 integer read-only
This object identifies the physical state of the port: noCard(1) no card present in this switch slot; noTransceiver(2) no Transceiver module in this port. noGbic(2) was used previously. Transceiver is the generic name for GBIC, SFP etc.; laserFault(3) the module is signaling a laser fault (defective Transceiver); noLight(4) the module is not receiving light; noSync(5) the module is receiving light but is out of sync; inSync(6) the module is receiving light and is in sync; portFault(7) the port is marked faulty (defective Transceiver, cable or device); diagFault(8) the port failed diagnostics (defective G_Port or FL_Port card or motherboard); lockRef(9) the port is locking to the reference signal. validating(10) Validation is in progress invalidModule(11) Invalid SFP unknown(255) unknown. Enumeration: 'invalidModule': 11, 'diagFault': 8, 'noLight': 4, 'unknown': 255, 'laserFault': 3, 'inSync': 6, 'lockRef': 9, 'validating': 10, 'noTransceiver': 2, 'noCard': 1, 'portFault': 7, 'noSync': 5.
             swFCPortOpStatus 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.4 integer read-only
This object identifies the operational status of the port. The online(1) state indicates that user frames can be passed. The unknown(0) state indicates that likely the port module is physically absent (see swFCPortPhyState). Enumeration: 'unknown': 0, 'offline': 2, 'testing': 3, 'faulty': 4, 'online': 1.
             swFCPortAdmStatus 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.5 integer read-write
The desired state of the port. A management station may place the port in a desired state by setting this object accordingly. The testing(3) state indicates that no user frames can be passed. As the result of either explicit management action or per configuration information accessible by the switch, swFCPortAdmStatus is then changed to either the online(1) or testing(3) states, or remains in the offline(2) state. Enumeration: 'offline': 2, 'testing': 3, 'faulty': 4, 'online': 1.
             swFCPortLinkState 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.6 integer read-write
This object indicates the link state of the port. The value may be: enabled(1) - port is allowed to participate in the FC-PH protocol with its attached port (or ports if it is in a FC-AL loop); disabled(2) - the port is not allowed to participate in the FC-PH protocol with its attached port(s); loopback(3) - the port may transmit frames through an internal path to verify the health of the transmitter and receiver path. Note that when the port's link state changes, its operational status (swFCPortOpStatus) will be affected. Enumeration: 'disabled': 2, 'enabled': 1, 'loopback': 3.
             swFCPortTxType 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.7 integer read-only
This object indicates the media transmitter type of the port. The value may be: unknown(1) cannot determined to the port driver lw(2) long wave laser sw(3) short wave laser ld(4) long wave LED cu(5) copper (electrical). Enumeration: 'unknown': 1, 'ld': 4, 'sw': 3, 'c': 5, 'lw': 2.
             swFCPortTxWords 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.11 counter32 read-only
This object counts the number of Fibre Channel words that the port has transmitted.
             swFCPortRxWords 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.12 counter32 read-only
This object counts the number of Fibre Channel words that the port has received.
             swFCPortTxFrames 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.13 counter32 read-only
This object counts the number of (Fibre Channel) frames that the port has transmitted.
             swFCPortRxFrames 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.14 counter32 read-only
This object counts the number of (Fibre Channel) frames that the port has received.
             swFCPortRxC2Frames 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.15 counter32 read-only
This object counts the number of Class 2 frames that the port has received.
             swFCPortRxC3Frames 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.16 counter32 read-only
This object counts the number of Class 3 frames that the port has received.
             swFCPortRxLCs 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.17 counter32 read-only
This object counts the number of Link Control frames that the port has received.
             swFCPortRxMcasts 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.18 counter32 read-only
This object counts the number of Multicast frames that the port has received.
             swFCPortTooManyRdys 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.19 counter32 read-only
This object counts the number of times when RDYs exceeds the frames received.
             swFCPortNoTxCredits 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.20 counter32 read-only
This object counts the number of times when the transmit credit has reached zero.
             swFCPortRxEncInFrs 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.21 counter32 read-only
This object counts the number of encoding error or disparity error inside frames received.
             swFCPortRxCrcs 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.22 counter32 read-only
This object counts the number of CRC errors detected for frames received.
             swFCPortRxTruncs 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.23 counter32 read-only
This object counts the number of truncated frames that the port has received.
             swFCPortRxTooLongs 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.24 counter32 read-only
This object counts the number of received frames that are too long.
             swFCPortRxBadEofs 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.25 counter32 read-only
This object counts the number of received frames that have bad EOF delimiter.
             swFCPortRxEncOutFrs 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.26 counter32 read-only
This object counts the number of encoding error or disparity error outside frames received.
             swFCPortRxBadOs 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.27 counter32 read-only
This object counts the number of invalid Ordered Sets received.
             swFCPortC3Discards 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.28 counter32 read-only
This object counts the number of Class 3 frames that the port has discarded.
             swFCPortMcastTimedOuts 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.29 counter32 read-only
This object counts the number of Multicast frames that has been timed out.
             swFCPortTxMcasts 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.30 counter32 read-only
This object counts the number of Multicast frames that has been transmitted.
             swFCPortLipIns 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.31 counter32 read-only
This object counts the number of Loop Initializations that has been initiated by loop devices attached.
             swFCPortLipOuts 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.32 counter32 read-only
This object counts the number of Loop Initializations that has been initiated by the port.
             swFCPortLipLastAlpa 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.33 octet string read-only
This object indicates the Physical Address (AL_PA) of the loop device that initiated the last Loop Initialization.
             swFCPortWwn 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.34 octet string read-only
The World_wide_Name of the Fibre Channel port. The contents of an instance are in the IEEE extended format as specified in FC-PH; the 12-bit port identifier represents the port number within the switch.
             swFCPortSpeed 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.35 integer read-write
The desired baud rate for the port. It can have the values of 1GB (1), 2GB (2), Auto-Negotiate (3), 4GB (4), 8GB (5), or 10GB (6). Some of the above values may not be supported by all type of switches. Enumeration: 'auto-Negotiate': 3, 'ten-GB': 6, 'unknown': 7, 'one-GB': 1, 'two-GB': 2, 'four-GB': 4, 'eight-GB': 5.
             swFCPortName 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.36 displaystring read-only
A string indicates the name of the addressed port. The names should be persistent across switch reboots. Port names do not have to be unique within a switch or within a fabric.
             swFCPortSpecifier 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.37 displaystring read-only
This string indicates the physical port number of the addressed port. The format of the string is: /port, where 'slot' being present only for bladed systems.
             swFCPortFlag 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.38 fcportflag read-only
A bit map of port status flags which includes the information of port type. Currently this will indicate if the port is virtual or physical.
             swFCPortBrcdType 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.39 integer read-only
The Brocade port type. Enumeration: 'g-port': 6, 'unknown': 1, 'f-port': 4, 'e-port': 5, 'other': 2, 'fl-port': 3, 'ex-port': 7.
 swEvent 1.3.6.1.4.1.1588.2.1.1.1.8
The OID sub-tree for swEvent group.
     swEventTable 1.3.6.1.4.1.1588.2.1.1.1.8.5 no-access
The table of event entries.
         swEventEntry 1.3.6.1.4.1.1588.2.1.1.1.8.5.1 no-access
An entry of the event table.
             swEventIndex 1.3.6.1.4.1.1588.2.1.1.1.8.5.1.1 integer32 read-only
This object identifies the event entry.
             swEventTimeInfo 1.3.6.1.4.1.1588.2.1.1.1.8.5.1.2 displaystring read-only
This object identifies the date and time when this event occurred, in textual format.
             swEventLevel 1.3.6.1.4.1.1588.2.1.1.1.8.5.1.3 integer read-only
This object identifies the severity level of this event entry. Enumeration: 'debug': 5, 'informational': 4, 'critical': 1, 'warning': 3, 'error': 2.
             swEventRepeatCount 1.3.6.1.4.1.1588.2.1.1.1.8.5.1.4 integer32 read-only
This object identifies how many times this particular event has occurred.
             swEventDescr 1.3.6.1.4.1.1588.2.1.1.1.8.5.1.5 displaystring read-only
This object identifies the textual description of the event.
             swEventVfId 1.3.6.1.4.1.1588.2.1.1.1.8.5.1.6 integer32 read-only
This object identifies the Virtual fabric id.