SYNOLOGY-UPS-MIB: View SNMP OID List / Download MIB

VENDOR: SYNOLOGY INC.


 Home MIB: SYNOLOGY-UPS-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 synology 1.3.6.1.4.1.6574
           synoUPS 1.3.6.1.4.1.6574.4
Characteristics of the ups information
               upsDevice 1.3.6.1.4.1.6574.4.1
                   upsDeviceModel 1.3.6.1.4.1.6574.4.1.1 displaystring read-only
Device model
                   upsDeviceManufacturer 1.3.6.1.4.1.6574.4.1.2 displaystring read-only
Device manufacturer
                   upsDeviceSerial 1.3.6.1.4.1.6574.4.1.3 displaystring read-only
Device serial number.
                   upsDeviceType 1.3.6.1.4.1.6574.4.1.4 displaystring read-only
Device type (ups, pdu, scd, psu)
                   upsDeviceDescription 1.3.6.1.4.1.6574.4.1.5 displaystring read-only
Device description.
                   upsDeviceContact 1.3.6.1.4.1.6574.4.1.6 displaystring read-only
Device administrator name.
                   upsDeviceLocation 1.3.6.1.4.1.6574.4.1.7 displaystring read-only
Device physical location.
                   upsDevicePart 1.3.6.1.4.1.6574.4.1.8 displaystring read-only
Device part number.
                   upsDeviceMACAddr 1.3.6.1.4.1.6574.4.1.9 displaystring read-only
Physical network address of the device.
               upsInfo 1.3.6.1.4.1.6574.4.2
                   upsInfoStatus 1.3.6.1.4.1.6574.4.2.1 displaystring read-only
UPS status.
                   upsInfoAlarm 1.3.6.1.4.1.6574.4.2.2 displaystring read-only
UPS alarms
                   upsInfoTime 1.3.6.1.4.1.6574.4.2.3 displaystring read-only
Internal UPS clock time
                   upsInfoDate 1.3.6.1.4.1.6574.4.2.4 displaystring read-only
Internal UPS clock date
                   upsInfoModel 1.3.6.1.4.1.6574.4.2.5 displaystring read-only
UPS model
                   upsInfoMfr 1.3.6.1.4.1.6574.4.2.6
                       upsInfoMfrName 1.3.6.1.4.1.6574.4.2.6.1 displaystring read-only
UPS manufacturer
                       upsInfoMfrDate 1.3.6.1.4.1.6574.4.2.6.2 displaystring read-only
UPS manufacturing date
                   upsInfoSerial 1.3.6.1.4.1.6574.4.2.7 displaystring read-only
UPS serial number
                   upsInfoVendorID 1.3.6.1.4.1.6574.4.2.8 displaystring read-only
Vendor ID for USB devices
                   upsInfoProductID 1.3.6.1.4.1.6574.4.2.9 displaystring read-only
Product ID for USB devices
                   upsInfoFirmware 1.3.6.1.4.1.6574.4.2.10
                         upsInfoFirmwareName 1.3.6.1.4.1.6574.4.2.10.1 displaystring read-only
UPS firmware
                         upsInfoFirmwareAux 1.3.6.1.4.1.6574.4.2.10.2 displaystring read-only
Auxiliary device firmware
                   upsInfoTemperature 1.3.6.1.4.1.6574.4.2.11 float read-only
UPS temperature (degrees C)
                   upsInfoLoad 1.3.6.1.4.1.6574.4.2.12
                         upsInfoLoadValue 1.3.6.1.4.1.6574.4.2.12.1 float read-only
Load on UPS (percent)
                         upsInfoLoadHigh 1.3.6.1.4.1.6574.4.2.12.2 float read-only
Load when UPS switches to overload condition (OVER) (percent)
                   upsInfoID 1.3.6.1.4.1.6574.4.2.13 displaystring read-only
UPS system identifier
                   upsInfoDelay 1.3.6.1.4.1.6574.4.2.14
                         upsInfoDelayStart 1.3.6.1.4.1.6574.4.2.14.1 nonnegativeinteger read-only
Interval to wait before restarting the load (seconds)
                         upsInfoDelayReboot 1.3.6.1.4.1.6574.4.2.14.2 nonnegativeinteger read-only
Interval to wait before rebooting the UPS (seconds)
                         upsInfoDelayShutdown 1.3.6.1.4.1.6574.4.2.14.3 nonnegativeinteger read-only
Interval to wait after shutdown with delay command (seconds)
                   upsInfoTimer 1.3.6.1.4.1.6574.4.2.15
                         upsInfoTimerStart 1.3.6.1.4.1.6574.4.2.15.1 nonnegativeinteger read-only
Time before the load will be started (seconds)
                         upsInfoTimerReboot 1.3.6.1.4.1.6574.4.2.15.2 nonnegativeinteger read-only
Time before the load will be rebooted (seconds)
                         upsInfoTimerShutdown 1.3.6.1.4.1.6574.4.2.15.3 nonnegativeinteger read-only
Time before the load will be shutdown (seconds)
                   upsInfoTest 1.3.6.1.4.1.6574.4.2.16
                         upsInfoTestInterval 1.3.6.1.4.1.6574.4.2.16.1 nonnegativeinteger read-only
Interval between self tests
                         upsInfoTestResult 1.3.6.1.4.1.6574.4.2.16.2 displaystring read-only
Results of last self test
                   upsInfoDisplayLanguage 1.3.6.1.4.1.6574.4.2.17 displaystring read-only
Language to use on front panel
                   upsInfoContacts 1.3.6.1.4.1.6574.4.2.18 displaystring read-only
UPS external contact sensors
                   upsInfoEffciency 1.3.6.1.4.1.6574.4.2.19 nonnegativeinteger read-only
Efficiency of the UPS (ratio of the output current on the input current) (percent)
                   upsInfoPower 1.3.6.1.4.1.6574.4.2.20
                         upsInfoPowerValue 1.3.6.1.4.1.6574.4.2.20.1 float read-only
Current value of apparent power (Volt-Amps)
                         upsInfoPowerNominal 1.3.6.1.4.1.6574.4.2.20.2 float read-only
Nominal value of apparent power (Volt-Amps)
                   upsInfoRealPower 1.3.6.1.4.1.6574.4.2.21
                         upsInfoRealPowerValue 1.3.6.1.4.1.6574.4.2.21.1 float read-only
Current value of real power (Watts)
                         upsInfoRealPowerNominal 1.3.6.1.4.1.6574.4.2.21.2 float read-only
Nominal value of real power (Watts)
                   upsInfoBeeperStatus 1.3.6.1.4.1.6574.4.2.22 displaystring read-only
UPS beeper status (enabled, disabled or muted)
                   upsInfoType 1.3.6.1.4.1.6574.4.2.23 displaystring read-only
UPS type
                   upsInfoWatchdogStatus 1.3.6.1.4.1.6574.4.2.24 displaystring read-only
UPS watchdog status (enabled or disabled)
                   upsInfoStart 1.3.6.1.4.1.6574.4.2.25
                         upsInfoStartAuto 1.3.6.1.4.1.6574.4.2.25.1 displaystring read-only
UPS starts when mains is (re)applied
                         upsInfoStartBattery 1.3.6.1.4.1.6574.4.2.25.2 displaystring read-only
Allow to start UPS from battery
                         upsInfoStartReboot 1.3.6.1.4.1.6574.4.2.25.3 displaystring read-only
UPS coldstarts from battery (enabled or disabled)
               upsBattery 1.3.6.1.4.1.6574.4.3
                   upsBatteryCharge 1.3.6.1.4.1.6574.4.3.1
                       upsBatteryChargeValue 1.3.6.1.4.1.6574.4.3.1.1 float read-only
Battery charge
                       upsBatteryChargeLow 1.3.6.1.4.1.6574.4.3.1.2 float read-only
Remaining battery level when UPS switches to LB (percent)
                       upsBatteryChargeRestart 1.3.6.1.4.1.6574.4.3.1.3 float read-only
Minimum battery level for UPS restart after power-off
                       upsBatteryChargeWarning 1.3.6.1.4.1.6574.4.3.1.4 float read-only
Battery level when UPS switches to Warning state (percent)
                   upsBatteryVoltage 1.3.6.1.4.1.6574.4.3.2
                       upsBatteryVoltageValue 1.3.6.1.4.1.6574.4.3.2.1 float read-only
The magnitude of the present battery voltage.
                       upsBatteryVoltageNominal 1.3.6.1.4.1.6574.4.3.2.2 float read-only
Nominal battery voltage.
                       upsBatteryVoltageLow 1.3.6.1.4.1.6574.4.3.2.3 float read-only
Minimum battery voltage, that triggers FSD status .
                       upsBatteryVoltageHigh 1.3.6.1.4.1.6574.4.3.2.4 float read-only
Maximum battery voltage (Ie battery.charge = 100).
                   upsBatteryCapacity 1.3.6.1.4.1.6574.4.3.3 float read-only
Battery capacity (Ah)
                   upsBatteryCurrent 1.3.6.1.4.1.6574.4.3.4 float read-only
The present battery current.
                   upsBatteryTemperature 1.3.6.1.4.1.6574.4.3.5 float read-only
The ambient temperature at or near the UPS Battery casing.
                   upsBatteryRuntime 1.3.6.1.4.1.6574.4.3.6
                       upsBatteryRuntimeValue 1.3.6.1.4.1.6574.4.3.6.1 nonnegativeinteger read-only
Battery runtime (seconds)
                       upsBatteryRuntimeLow 1.3.6.1.4.1.6574.4.3.6.2 nonnegativeinteger read-only
Remaining battery runtime when UPS switches to LB (seconds)
                       upsBatteryRuntimeRestart 1.3.6.1.4.1.6574.4.3.6.3 nonnegativeinteger read-only
Minimum battery runtime for UPS restart after power-off (seconds)
                   upsBatteryAlarmThreshold 1.3.6.1.4.1.6574.4.3.7 displaystring read-only
Battery alarm threshold
                   upsBatteryDate 1.3.6.1.4.1.6574.4.3.8 displaystring read-only
Battery change date
                   upsBatteryMfrDate 1.3.6.1.4.1.6574.4.3.9 displaystring read-only
Battery manufacturing date
                   upsBatteryPacks 1.3.6.1.4.1.6574.4.3.10 nonnegativeinteger read-only
Number of battery packs
                   upsBatteryPacksBad 1.3.6.1.4.1.6574.4.3.11 nonnegativeinteger read-only
Number of bad battery packs
                   upsBatteryType 1.3.6.1.4.1.6574.4.3.12 displaystring read-only
Battery chemistry
                   upsBatteryProtection 1.3.6.1.4.1.6574.4.3.13 displaystring read-only
Prevent deep discharge of battery
                   upsBatteryEnergySave 1.3.6.1.4.1.6574.4.3.14 displaystring read-only
Switch off when running on battery and no/low load
               upsInput 1.3.6.1.4.1.6574.4.4
                   upsInputVoltage 1.3.6.1.4.1.6574.4.4.1
                       upsInputVoltageValue 1.3.6.1.4.1.6574.4.4.1.1 float read-only
Input voltage
                       upsInputVoltageMax 1.3.6.1.4.1.6574.4.4.1.2 float read-only
Maximum incoming voltage seen
                       upsInputVoltageMin 1.3.6.1.4.1.6574.4.4.1.3 float read-only
Minimum incoming voltage seen
                       upsInputVoltageNominal 1.3.6.1.4.1.6574.4.4.1.4 float read-only
Nominal input voltage
                       upsInputVoltageExtend 1.3.6.1.4.1.6574.4.4.1.5 displaystring read-only
Extended input voltage range
                       upsInputVoltageFault 1.3.6.1.4.1.6574.4.4.1.6 float read-only
Input voltage Fault
                   upsInputTransfer 1.3.6.1.4.1.6574.4.4.2
                       upsInputTransferReason 1.3.6.1.4.1.6574.4.4.2.1 displaystring read-only
Reason for last transfer to battery
                       upsInputTransferLow 1.3.6.1.4.1.6574.4.4.2.2 float read-only
Low voltage transfer point
                       upsInputTransferHigh 1.3.6.1.4.1.6574.4.4.2.3 float read-only
High voltage transfer point
                       upsInputTransferLowMin 1.3.6.1.4.1.6574.4.4.2.4 float read-only
smallest settable low voltage transfer point
                       upsInputTransferLowMax 1.3.6.1.4.1.6574.4.4.2.5 float read-only
greatest settable low voltage transfer point
                       upsInputTransferHighMin 1.3.6.1.4.1.6574.4.4.2.6 float read-only
smallest settable high voltage transfer point
                       upsInputTransferHighMax 1.3.6.1.4.1.6574.4.4.2.7 float read-only
greatest settable high voltage transfer point
                       upsInputTransferBoostLow 1.3.6.1.4.1.6574.4.4.2.8 float read-only
Low voltage boosting transfer point
                       upsInputTransferBoostHigh 1.3.6.1.4.1.6574.4.4.2.9 float read-only
High voltage boosting transfer point
                       upsInputTransferTrimLow 1.3.6.1.4.1.6574.4.4.2.10 float read-only
Low voltage trimming transfer point
                       upsInputTransferTrimHigh 1.3.6.1.4.1.6574.4.4.2.11 float read-only
High voltage trimming transfer point
                   upsInputSensitivity 1.3.6.1.4.1.6574.4.4.3 displaystring read-only
Input power sensitivity
                   upsInputQuality 1.3.6.1.4.1.6574.4.4.4 displaystring read-only
Input power quality
                   upsInputCurrent 1.3.6.1.4.1.6574.4.4.5
                       upsInputCurrentValue 1.3.6.1.4.1.6574.4.4.5.1 float read-only
Input current (A)
                       upsInputCurrentNominal 1.3.6.1.4.1.6574.4.4.5.2 float read-only
Nominal input current (A)
                   upsInputFrequency 1.3.6.1.4.1.6574.4.4.6
                       upsInputFrequencyValue 1.3.6.1.4.1.6574.4.4.6.1 float read-only
Input line frequency (Hz)
                       upsInputFrequencyNominal 1.3.6.1.4.1.6574.4.4.6.2 float read-only
Nominal input line frequency (Hz)
                       upsInputFrequencyLow 1.3.6.1.4.1.6574.4.4.6.3 float read-only
Input line frequency low (Hz)
                       upsInputFrequencyHigh 1.3.6.1.4.1.6574.4.4.6.4 float read-only
Input line frequency high (Hz)
                       upsInputFrequencyExtend 1.3.6.1.4.1.6574.4.4.6.5 displaystring read-only
Extended input frequency range
               upsOutput 1.3.6.1.4.1.6574.4.5
                   upsOutputVoltage 1.3.6.1.4.1.6574.4.5.1
                       upsOutputVoltageValue 1.3.6.1.4.1.6574.4.5.1.1 float read-only
Output voltage (V)
                       upsOutputVoltageNominal 1.3.6.1.4.1.6574.4.5.1.2 float read-only
Nominal output voltage (V)
                   upsOutputFrequency 1.3.6.1.4.1.6574.4.5.2
                       upsOutputFrequencyValue 1.3.6.1.4.1.6574.4.5.2.1 float read-only
Output frequency (Hz)
                       upsOutputFrequencyNominal 1.3.6.1.4.1.6574.4.5.2.2 float read-only
Nominal output frequency (Hz)
                   upsOutputCurrent 1.3.6.1.4.1.6574.4.5.3
                       upsOutputCurrentValue 1.3.6.1.4.1.6574.4.5.3.1 float read-only
Output current (A)
                       upsOutputCurrentNominal 1.3.6.1.4.1.6574.4.5.3.2 float read-only
Nominal output current (A)
               upsAmbient 1.3.6.1.4.1.6574.4.6
                   upsAmbientTemperature 1.3.6.1.4.1.6574.4.6.1
                       upsAmbientTemperatureValue 1.3.6.1.4.1.6574.4.6.1.1 float read-only
Ambient temperature (degrees C)
                       upsAmbientTemperatureAlarm 1.3.6.1.4.1.6574.4.6.1.2 displaystring read-only
Temperature alarm (enabled/disabled)
                       upsAmbientTemperatureHigh 1.3.6.1.4.1.6574.4.6.1.3 float read-only
Temperature threshold high (degrees C)
                       upsAmbientTemperatureLow 1.3.6.1.4.1.6574.4.6.1.4 float read-only
Temperature threshold low (degrees C)
                       upsAmbientTemperatureMax 1.3.6.1.4.1.6574.4.6.1.5 float read-only
Maximum temperature seen (degrees C)
                       upsAmbientTemperatureMin 1.3.6.1.4.1.6574.4.6.1.6 float read-only
Minimum temperature seen (degrees C)
                   upsAmbientHumidity 1.3.6.1.4.1.6574.4.6.2
                       upsAmbientHumidityValue 1.3.6.1.4.1.6574.4.6.2.1 float read-only
Ambient relative humidity (percent)
                       upsAmbientHumidityAlarm 1.3.6.1.4.1.6574.4.6.2.2 displaystring read-only
Relative humidity alarm (enabled/disabled)
                       upsAmbientHumidityHigh 1.3.6.1.4.1.6574.4.6.2.3 float read-only
Relative humidity threshold high (percent)
                       upsAmbientHumidityLow 1.3.6.1.4.1.6574.4.6.2.4 float read-only
Relative humidity threshold low (percent)
                       upsAmbientHumidityMax 1.3.6.1.4.1.6574.4.6.2.5 float read-only
Maximum relative humidity seen (percent)
                       upsAmbientHumidityMin 1.3.6.1.4.1.6574.4.6.2.6 float read-only
Minimum relative humidity seen (percent)
               upsDriver 1.3.6.1.4.1.6574.4.7
                   upsDriverName 1.3.6.1.4.1.6574.4.7.1 displaystring read-only
Driver name
                   upsDriverVersion 1.3.6.1.4.1.6574.4.7.2 displaystring read-only
Driver version (NUT release)
                   upsDriverVersionData 1.3.6.1.4.1.6574.4.7.3 displaystring read-only
Driver version data
                   upsDriverVersionInternal 1.3.6.1.4.1.6574.4.7.4 displaystring read-only
Internal driver version (if tracked separately)
                   upsDriverPollInterval 1.3.6.1.4.1.6574.4.7.5 integer32 read-only
Poll interval setup in configuration file
                   upsDriverPort 1.3.6.1.4.1.6574.4.7.6 displaystring read-only
Port setup in configuration file
                   upsDriverPollFrequency 1.3.6.1.4.1.6574.4.7.7 integer32 read-only
Poll frequency
                   upsDriverProductID 1.3.6.1.4.1.6574.4.7.8 displaystring read-only
Product ID
                   upsDriverSnmpVersion 1.3.6.1.4.1.6574.4.7.9 displaystring read-only
Snmp version
               upsServer 1.3.6.1.4.1.6574.4.8
                   upsServerInfo 1.3.6.1.4.1.6574.4.8.1 displaystring read-only
Server information
                   upsServerVersion 1.3.6.1.4.1.6574.4.8.2 displaystring read-only
Server version
               upsConformance 1.3.6.1.4.1.6574.4.9
                   upsCompliances 1.3.6.1.4.1.6574.4.9.1
                       upsCompliance 1.3.6.1.4.1.6574.4.9.1.1
The compliance statement for synoSystem entities which implement the SYNOLOGY SYSTEM MIB.
                   upsGroups 1.3.6.1.4.1.6574.4.9.2
                       upsGroup 1.3.6.1.4.1.6574.4.9.2.1
A collection of objects providing basic information of an synology ups entity.