SIAE-CFGM-MIB: View SNMP OID List / Download MIB

VENDOR: SIAE MICROELETTRONICA S.P.A.


 Home MIB: SIAE-CFGM-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
     configManagementFtpStatusTrap 1.3.6.1.4.1.3373.1103.0.3001
This event is generated by ALCP2E-NE when the status of configuration transfer is changed. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) configurationState 3) configurationFailure
 configManagement 1.3.6.1.4.1.3373.1103.30
Backup and Restore (Configuration management) of the NE
       configManagementMibVersion 1.3.6.1.4.1.3373.1103.30.1 integer read-only
Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01.
       configManagementFileName 1.3.6.1.4.1.3373.1103.30.2 displaystring read-write
Name of the file, containing the equipment configuration, to upload or download according to the object configManagementAction
       configManagementServerIpAddress 1.3.6.1.4.1.3373.1103.30.3 ipaddress read-write
Ip address of the SNMP manager connected from/to which the configuration is downloaded/uploaded, if this object is set '0.0.0.0', then the IP address of server is read from incoming ethernet packet.
       configManagementAction 1.3.6.1.4.1.3373.1103.30.4 integer read-write
Action requested to the equipment: - configNone: no action required; - configSave: the current equipment configuration will be saved in the file whose name is written in the leaf configurationFileName through FTP protocol; - configUse: the configuration file, whose name is written in the leaf configurationFileName, will be transfer- red on the target through FTP protocol and it will be used after an implicit restart of the equip- ment. A copy of the current equipment configuration will be saved on the equipment filesystem in order to return to it. - configBack: the equipment configuration, saved during a config-use action will be used after an implicit restart of the equipment. - configAbort: the action in progress will be interrupted. - configBackAndSwich: the equipment configuration, saved during a config-use action will be used after an implicit bench switch of the equipment. The value of this object is self cleared (reset to the value configNone) after its use. Enumeration: 'configAbort': 4, 'configBack': 3, 'configNone': 0, 'configUse': 2, 'configSave': 1, 'configUseAndSwitch': 5.
       configManagementState 1.3.6.1.4.1.3373.1103.30.5 integer read-only
Action in progess state: - configCompleted: the action required has been successfully completed; - configInterrupted: the action required has been abnormally stopped; - configVerifying: the downloaded configuration is being checked if it is suitable for the equipment; - configSaving: current configuration is being saved to be tranferred to the manager; - configUploading: the current configuration is being transfer- red to the manager; - configDownloading: a configuration file is being transferred from the manager to the equipment; - configUsing: the current configuration is being overwrit- ten with the downloaded one or with the previously saved one; - configMaking-copy: a copy of the current configuration is being saved to eventually return to it; - configAborting: the current action is being aborted as requi- red by the config-abort action. - configRestarting: the equipment is restarting. - configStarted: the action required has been started; A trap is sent at every change of the object value. When the status become configStarted, the sent trap notifies the start of the required action. When the status become configCompleted or config-interrupted, the sent trap notifies a successfully or an abnormal end of the action in progress. Enumeration: 'configUsing': 7, 'configUploading': 6, 'configVerifying': 3, 'configCompleted': 1, 'configDownloading': 5, 'configSaving': 4, 'configMakingCopy': 8, 'configStarted': 11, 'configInterrupted': 2, 'configAborting': 9, 'configRestarting': 10.
       configManagementFailure 1.3.6.1.4.1.3373.1103.30.6 integer read-only
The value of this object identifies the configuration upload/ download state in which errors have been detected. The value config-aborted means interrupted by user. Enumeration: 'configUsing': 7, 'configUploading': 6, 'configNoFailure': 0, 'configVerifying': 3, 'configDownloading': 5, 'configMakingCopy': 8, 'configSaving': 4, 'configAborted': 9.
       configManagementBackupFileDate 1.3.6.1.4.1.3373.1103.30.7 unsigned32 read-only
Date and time of the previous configuration file saved by the config-use action. The value of this object is expressed as the number of seconds since the midnight of 1/1/1970. A zero value means no previous configuration file has been created.
       configManagementTrapNotification 1.3.6.1.4.1.3373.1103.30.8 integer read-write
Enable/disable the trap generation on configuration tranfer operation Enumeration: 'trapDisable': 1, 'trapEnable': 2.