RS232-MIB: View SNMP OID List / Download MIB

VENDOR: INTERNET-STANDARD


 Home MIB: RS232-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 rs232 1.3.6.1.3.20
       rs232Number 1.3.6.1.3.20.1 integer read-only
The number of ports (regardless of their current state) in the RS-232-like general port table.
       rs232PortTable 1.3.6.1.3.20.2 no-access
A list of port entries. The number of entries is given by the value of rs232Number.
           rs232PortEntry 1.3.6.1.3.20.2.1 no-access
Status and parameter values for a port.
               rs232PortIndex 1.3.6.1.3.20.2.1.1 integer read-only
A unique value for each port. Its value ranges between 1 and the value of rs232Number. By convention and if possible, hardware port numbers map directly to external connectors. The value for each port must remain constant at least from one re-initialization of the network management agent to the next.
               rs232PortType 1.3.6.1.3.20.2.1.2 integer read-only
The port's hardware type. Enumeration: 'v35': 5, 'other': 1, 'rs422': 3, 'rs232': 2, 'rs423': 4.
               rs232PortInSigNumber 1.3.6.1.3.20.2.1.3 integer read-only
The number of input signals for the port in the input signal table (rs232PortInSigTable). The table contains entries only for those signals the software can detect.
               rs232PortOutSigNumber 1.3.6.1.3.20.2.1.4 integer read-only
The number of output signals for the port in the output signal table (rs232PortOutSigTable). The table contains entries only for those signals the software can assert.
               rs232PortInSpeed 1.3.6.1.3.20.2.1.5 integer read-write
The port's input speed in bits per second.
               rs232PortOutSpeed 1.3.6.1.3.20.2.1.6 integer read-write
The port's output speed in bits per second.
       rs232AsyncPortTable 1.3.6.1.3.20.3 no-access
A list of asynchronous port entries. The maximum entry number is given by the value of rs232Number. Entries need not exist for synchronous ports.
           rs232AsyncPortEntry 1.3.6.1.3.20.3.1 no-access
Status and parameter values for an asynchronous port.
               rs232AsyncPortIndex 1.3.6.1.3.20.3.1.1 integer read-only
A unique value for each port. Its value is the same as rs232PortIndex for the port.
               rs232AsyncPortBits 1.3.6.1.3.20.3.1.2 integer read-write
The port's number of bits in a character.
               rs232AsyncPortStopBits 1.3.6.1.3.20.3.1.3 integer read-write
The port's number of stop bits. Enumeration: 'dynamic': 4, 'two': 2, 'one-and-half': 3, 'one': 1.
               rs232AsyncPortParity 1.3.6.1.3.20.3.1.4 integer read-write
The port's sense of a character parity bit. Enumeration: 'even': 3, 'none': 1, 'space': 5, 'odd': 2, 'mark': 4.
               rs232AsyncPortAutobaud 1.3.6.1.3.20.3.1.5 integer read-write
A control for the port's ability to automatically sense input speed. When rs232PortAutoBaud is 'enabled', a port may autobaud to values different from the set values for speed, parity, and character size. As a result a network management system may temporarily observe values different from what was previously set. Enumeration: 'disabled': 2, 'enabled': 1.
               rs232AsyncPortParityErrs 1.3.6.1.3.20.3.1.6 counter read-only
Total number of characters with a parity error, input from the port since system re-initialization and while the port state was 'up' or 'test'.
               rs232AsyncPortFramingErrs 1.3.6.1.3.20.3.1.7 counter read-only
Total number of characters with a framing error, input from the port since system re-initialization and while the port state was 'up' or 'test'.
               rs232AsyncPortOverrunErrs 1.3.6.1.3.20.3.1.8 counter read-only
Total number of characters with an overrun error, input from the port since system re-initialization and while the port state was 'up' or 'test'.
       rs232SyncPortTable 1.3.6.1.3.20.4 no-access
A list of synchronous port entries. The maximum entry number is given by the value of rs232Number. Entries need not exist for asynchronous ports.
           rs232SyncPortEntry 1.3.6.1.3.20.4.1 no-access
Status and parameter values for a synchronous port.
               rs232SyncPortIndex 1.3.6.1.3.20.4.1.1 integer read-only
A unique value for each port. Its value is the same as rs232PortIndex for the port.
               rs232SyncPortClockSource 1.3.6.1.3.20.4.1.2 integer read-write
Source of the port's bit rate clock. 'split' means the tranmit clock is internal and the receive clock is external. Enumeration: 'internal': 1, 'external': 2, 'split': 3.
               rs232SyncPortFrameCheckErrs 1.3.6.1.3.20.4.1.3 counter read-only
Total number of frames with an invalid frame check sequence, input from the port since system re-initialization and while the port state was 'up' or 'test'.
               rs232SyncPortTransmitUnderrunErrs 1.3.6.1.3.20.4.1.4 counter read-only
Total number of frames that failed to be transmitted on the port since system re-initialization and while the port state was 'up' or 'test' because data was not available to the transmitter in time.
               rs232SyncPortReceiveOverrunErrs 1.3.6.1.3.20.4.1.5 counter read-only
Total number of frames that failed to be received on the port since system re-initialization and while the port state was 'up' or 'test' because the receiver did not accept the data in time.
               rs232SyncPortInterruptedFrames 1.3.6.1.3.20.4.1.6 counter read-only
Total number of frames that failed to be received or transmitted on the port due to loss of modem signals since system re-initialization and while the port state was 'up' or 'test'.
               rs232SyncPortAbortedFrames 1.3.6.1.3.20.4.1.7 counter read-only
Number of frames aborted on the port due to receiving an abort sequence since system re-initialization and while the port state was 'up' or 'test'.
       rs232InSigTable 1.3.6.1.3.20.5 no-access
A list of port input control signal entries.
           rs232InSigEntry 1.3.6.1.3.20.5.1 no-access
Input control signal status for a hardware port.
               rs232InSigPortIndex 1.3.6.1.3.20.5.1.1 integer read-only
The value of rs232PortIndex for the port to which this entry belongs.
               rs232InSigName 1.3.6.1.3.20.5.1.2 integer read-only
Identification of a hardware signal, as follows: rts Request to Send cts Clear to Send dsr Data Set Ready dtr Data Terminal Ready ri Ring Indicator dcd Received Line Signal Detector sq Signal Quality Detector srs Data Signaling Rate Selector srts Secondary Request to Send scts Secondary Clear to Send sdcd Secondary Received Line Signal Detector Enumeration: 'sq': 7, 'cts': 2, 'srts': 9, 'dcd': 6, 'dsr': 3, 'srs': 8, 'rts': 1, 'scts': 10, 'dtr': 4, 'sdcd': 11, 'ri': 5.
               rs232InSigState 1.3.6.1.3.20.5.1.3 integer read-only
The current signal state. Enumeration: 'on': 2, 'none': 1, 'off': 3.
               rs232InSigChanges 1.3.6.1.3.20.5.1.4 counter read-only
The number of times the signal has changed from 'on' to 'off' or from 'off' to 'on'.
       rs232OutSigTable 1.3.6.1.3.20.6 no-access
A list of port output control signal entries.
           rs232OutSigEntry 1.3.6.1.3.20.6.1 no-access
Output control signal status for a hardware port.
               rs232OutSigPortIndex 1.3.6.1.3.20.6.1.1 integer read-only
The value of rs232PortIndex for the port to which this entry belongs.
               rs232OutSigName 1.3.6.1.3.20.6.1.2 integer read-only
Identification of a hardware signal, as follows: rts Request to Send cts Clear to Send dsr Data Set Ready dtr Data Terminal Ready ri Ring Indicator dcd Received Line Signal Detector sq Signal Quality Detector srs Data Signaling Rate Selector srts Secondary Request to Send scts Secondary Clear to Send sdcd Secondary Received Line Signal Detector Enumeration: 'sq': 7, 'cts': 2, 'srts': 9, 'dcd': 6, 'dsr': 3, 'srs': 8, 'rts': 1, 'scts': 10, 'dtr': 4, 'sdcd': 11, 'ri': 5.
               rs232OutSigState 1.3.6.1.3.20.6.1.3 integer read-only
The current signal state. Enumeration: 'on': 2, 'none': 1, 'off': 3.
               rs232OutSigChanges 1.3.6.1.3.20.6.1.4 counter read-only
The number of times the signal has changed from 'on' to 'off' or from 'off' to 'on'.