POWER-ETHERNET-OLD-MIB: View SNMP OID List / Download MIB

VENDOR: INTERNET-STANDARD


 Home MIB: POWER-ETHERNET-OLD-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 aPowerEthernetMIB 1.3.6.1.2.1.10.7.20
The MIB module for for managing Powered Devices (PD) or Power Source Equipment (PSE) working according to the IEEE 802.af Powered Ethernet (DTE Power via MDI) standard. The following terms are used throughout this MIB module. For complete formal definitions, the IEEE 802.3 standards should be consulted wherever possible: Group - A recommended, but optional, entity defined by the IEEE 802.3 management standard, in order to support a modular numbering scheme. The classical example allows an implementor to represent field-replaceable units as groups of ports, with the port numbering matching the modular hardware implementation. Port - This entity identifies the port within the group for which this entry contains information. The numbering scheme for ports is implementation specific.
       aPethObjects 1.3.6.1.2.1.10.7.20.1
           aPethPsePortTable 1.3.6.1.2.1.10.7.20.1.1 no-access
A table of objects that display and control the power characteristics power Ethernet ports on a Power Source Entity (PSE) device. This group will be implemented in managed power Ethernet switches and mid-span devices.
               aPethPsePortEntry 1.3.6.1.2.1.10.7.20.1.1.1 no-access
A set of objects that display and control the power characteristics of a power Ethernet PSE port.
                   aPethPsePortGroupIndex 1.3.6.1.2.1.10.7.20.1.1.1.1 integer no-access
This variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices . aPethPseMidSpanGroupCapacity is the number of Mid-Span PSE groups that can be contained within the Mid-Span PSE.
                   aPethPsePortIndex 1.3.6.1.2.1.10.7.20.1.1.1.2 integer no-access
This variable uniquely identifies the power Ethernet PSE port within group aPethPseGroupIndex to which the power Ethernet PSE entry is connected.
                   aPethPsePortAdminEnable 1.3.6.1.2.1.10.7.20.1.1.1.3 integer read-write
Enables power supply on this port. Setting this object at a value enable(1) enables power and detection mechanism for this port. Setting this object at a value disable(2) disables power for this port. Enumeration: 'enable': 1, 'disable': 2.
                   aPethPsePortPowerPairsControlAbility 1.3.6.1.2.1.10.7.20.1.1.1.4 truthvalue read-only
Describes the capability of controlling the power pairs functionality to switch pins for sourcing power. The value true indicate that the device has the capability to control the power pairs
                   aPethPsePortPowerPairs 1.3.6.1.2.1.10.7.20.1.1.1.5 integer read-write
Describes or controls the pairs in use. If the value of aPethPsePortPowerPairsControl is true, this object is writable. A value of signal(1) menas that the signal pairs only are in use. A value of spare(2) means that the spare pairs only are in use. Enumeration: 'signal': 1, 'spare': 2.
                   aPethPsePortPowerDetectionControl 1.3.6.1.2.1.10.7.20.1.1.1.6 integer read-write
Controls the power detection mechanism of the port. Setting the value auto(1) enables the power detection mechanism of the port. Setting the value test(2) puts the port in a testmode: force continuous discovery without applying power regardless of whether PD detected. Enumeration: 'test': 2, 'auto': 1.
                   aPethPsePortDetectionStatus 1.3.6.1.2.1.10.7.20.1.1.1.7 integer read-only
Describes the operational status of the port PD detection. A value of disabled(1)- indicates that the PSE State diagram is in the state IDLE A value of searching(2)- indicates that the PSE State diagram is in the state DETECTION, CLASSIFICATION, SIGNATURE_INVALID or BACKOFF. A value of deliveringPower(4) - indicates that the PSE State diagram is in the state POWER_UP, POWER_ON or POWER_OFF. A value of fault(5) - indicates that the PSE State diagram is in the state TEST_ERROR or the state IDLE due to the variable error condition. Faults detected are vendor specific. A value of test(7) - indicates that the PSE State diagram is in the state TEST_MODE. A value of denyLowPriority(8) indicates that the port was disabled by the power management system, in order to keep active higher priority ports. Enumeration: 'fault': 5, 'searching': 2, 'deliveringPower': 4, 'disabled': 1, 'test': 7, 'denyLowPriority': 8.
                   aPethPsePortPowerPriority 1.3.6.1.2.1.10.7.20.1.1.1.8 integer read-write
This object controls the priority of the port from the point of view of a power management algorithm. The priority that is set by this variable could be used by a control mechanism that prevents over current situations by disconnecting first ports with lower power priority. Ports that connect devices critical to the operation of the network - like the E911 telephones ports - should be set to higher priority. Enumeration: 'high': 2, 'critical': 1, 'low': 3.
                   aPethPsePortPowerMaintenanceStatus 1.3.6.1.2.1.10.7.20.1.1.1.10 integer read-only
The value ok(1) indicates the Power Maintenance Signature is present and the overcurrent condition has not been detected. The value overCurrent (2) indicates an overcurrent condition has been detected. The value mPSAbsent(3) indicates that the Power Maintenance Signature is absent. Enumeration: 'mPSAbsent': 3, 'underCurrent': 2, 'ok': 1.
                   aPethPsePortMPSAbsentCounter 1.3.6.1.2.1.10.7.20.1.1.1.11 counter32 read-only
Counts the number of times that the aPethPsePortPowerMaintenanceStatus attribute changes from any value to the value mPSAbsent(3).
                   aPethPsePortOverCurrentCounter 1.3.6.1.2.1.10.7.20.1.1.1.12 counter32 read-only
Counts the number of times that the aPSEPowerCurrentStatus attribute changes from any value to the value overCurrent(2).
                   aPethPsePortType 1.3.6.1.2.1.10.7.20.1.1.1.13 integer read-write
A manager will set the value of this variable to a value that indicates the type of the device that is connected to theport. This value can be the result of the mapping the address of the station connected to the port and of the value of the aPethPdPortType of the respective PD port. Enumeration: 'wireless': 4, 'webcam': 3, 'other': 1, 'telephone': 2.
                   aPethPsePortPowerClassifications 1.3.6.1.2.1.10.7.20.1.1.1.14 integer read-only
Classification is a way to tag different terminals on the Power over LAN network according to their power consumption. Devices such as IP telephones, WLAN access points and others, will be classified according to their power requirements. The value is only valid while a valid PD is being detected as indicated by the attribute aPethPsePortDetectionStatus reporting the value or deliveringPower(4). Enumeration: 'class4': 5, 'class2': 3, 'class3': 4, 'class0': 1, 'class1': 2.
           aPethPdPortTable 1.3.6.1.2.1.10.7.20.1.2 no-access
A table of objects that display and control the power characteristics power Ethernet ports on a Powered Device(PD) device. This group will be implemented in managed powered and mid-span devices.
               aPethPdPortEntry 1.3.6.1.2.1.10.7.20.1.2.1 no-access
A set of objects that display and control the power characteristics of a Powered Device port.
                   aPethPdPortIndex 1.3.6.1.2.1.10.7.20.1.2.1.1 integer no-access
An index value that uniquely identifies an interface to a PD device. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex. The mapping between the ifIndex values and the numbering of the port on the device is an implementation issue.
                   aPethPdPortAdminEnable 1.3.6.1.2.1.10.7.20.1.2.1.2 integer read-write
This value identifies the operational state of the PD functions. An interface which can provide the PD functions will be enabled to do so when this attribute has the value enable. When this attribute has the value disable the interface will act as it would if it had no PD function. Enumeration: 'enable': 1, 'disable': 2.
           aPethMainPseObjects 1.3.6.1.2.1.10.7.20.1.3
               aPethMainPseTable 1.3.6.1.2.1.10.7.20.1.3.1 no-access
A table of objects that display and control the Main power on a PSE device. Example - an Ethernet switch midspan device can control an Ethnternet port and the Main Power supply unit's.
                   aPethMainPseEntry 1.3.6.1.2.1.10.7.20.1.3.1.1 no-access
A set of objects that display and control the Main power of a PSE.
                       aPethMainPseGroupIndex 1.3.6.1.2.1.10.7.20.1.3.1.1.1 integer no-access
This variable uniquely identifies the group to which power Ethernet PSE is connected.Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices
                       aPethMainPsePower 1.3.6.1.2.1.10.7.20.1.3.1.1.2 integer32 read-only
The nominal power of the PSE expressed in Watts.
                       aPethMainPseOperStatus 1.3.6.1.2.1.10.7.20.1.3.1.1.3 integer read-only
The operational status of the main PSE. Enumeration: 'on': 1, 'faulty': 3, 'off': 2.
                       aPethMainPseConsumptionPower 1.3.6.1.2.1.10.7.20.1.3.1.1.4 gauge32 read-only
Measured usage power expressed in Watts.
                       aPethMainPseBackupPresent 1.3.6.1.2.1.10.7.20.1.3.1.1.5 integer read-only
reflects the presence of a backup PSE . Enumeration: 'notPresent': 2, 'faulty': 3, 'present': 1.
                       aPethMainPseBackupActivated 1.3.6.1.2.1.10.7.20.1.3.1.1.6 truthvalue read-only
- reflects the activation status of the backup PSE . The value true Backup is activated.
                       aPethMainPseUsageThreshold 1.3.6.1.2.1.10.7.20.1.3.1.1.7 integer read-write
The usage threshold expressed in percents for comparing the measured power and initiating an alarm if the threshold is exceeded.
                       aPethMainPseMaximumDcPower 1.3.6.1.2.1.10.7.20.1.3.1.1.8 integer read-write
Describes the maximum available power in Watt to be supplied by the DC backup source to this device.
           aPethNotificationControl 1.3.6.1.2.1.10.7.20.1.4
               aPethNotificationControlTable 1.3.6.1.2.1.10.7.20.1.4.1 no-access
A table of objects that display and control the Notification on a PSE device.
                   aPethNotificationControlEntry 1.3.6.1.2.1.10.7.20.1.4.1.1 no-access
A set of objects that control the Notification events.
                       aPethNotificationControlGroupIndex 1.3.6.1.2.1.10.7.20.1.4.1.1.1 integer no-access
This variable uniquely identifies the group. Group means box in the stack, module in a rack and it is RECOMENDED that the value 1 be used for non-modular devices
                       aPethNotificationControlEnable 1.3.6.1.2.1.10.7.20.1.4.1.1.2 integer read-write
Enable Notification from Agent Enumeration: 'enable': 1, 'disable': 2.
       aPethNotifications 1.3.6.1.2.1.10.7.20.2
           aPethPsePortOnOffNotification 1.3.6.1.2.1.10.7.20.2.1
This Notification indicates if Pse Port is delivering or not power to the PD. This Notification SHOULD be sent on every status change except in the searching mode.
           aPethPsePortPowerMaintenanceStatusNotification 1.3.6.1.2.1.10.7.20.2.2
This Notification indicates a Port Change Status and it SHOULD be sent on every status change.
           aPethMainPseBackUpActivatedNotification 1.3.6.1.2.1.10.7.20.2.3
This Notification indicate BackUp is Activated or BackUp is released.
           aPethMainPowerUsageOnNotification 1.3.6.1.2.1.10.7.20.2.4
This Notification indicate PSE Threshold usage indication is on, the usage power is above the threshold.
           aPethMainPowerUsageOffNotification 1.3.6.1.2.1.10.7.20.2.5
This Notification indicate PSE Threshold usage indication off, the usage power is below the threshold.
       aPethConformance 1.3.6.1.2.1.10.7.20.3
           aPethCompliances 1.3.6.1.2.1.10.7.20.3.1
               aPethCompliance 1.3.6.1.2.1.10.7.20.3.1.1
Describes the requirements for conformance to the Power Ethernet MIB.
               aPethPseCompliance 1.3.6.1.2.1.10.7.20.3.1.2
Describes the requirements for conformance to the PSE and MID- Span.
               aPethPdCompliance 1.3.6.1.2.1.10.7.20.3.1.3
Describes the requirements for conformance to the PD.
               aPethPsePortNotificationGroup 1.3.6.1.2.1.10.7.20.3.1.4
Pse Notification indications
               aPethMainPowerNotificationGroup 1.3.6.1.2.1.10.7.20.3.1.5
Pse Notification indications
           aPethGroups 1.3.6.1.2.1.10.7.20.3.2
               aPethPsePortGroup 1.3.6.1.2.1.10.7.20.3.2.1
PSE Port Objects.
               aPethPdPortGroup 1.3.6.1.2.1.10.7.20.3.2.2
PD Port Objects.
               aPethMainPseGroup 1.3.6.1.2.1.10.7.20.3.2.3
Main PSE Objects.
               aPethNotificationControlGroup 1.3.6.1.2.1.10.7.20.3.2.4
Notification Control Objects.