OMNI-gx2Dm200-MIB: View SNMP OID List / Download MIB

VENDOR: GENERAL INSTRUMENT


 Home MIB: OMNI-gx2Dm200-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 gx2Dm200Descriptor 1.3.6.1.4.1.1166.6.1.2.19.1
 gx2Dm200AnalogTable 1.3.6.1.4.1.1166.6.1.2.19.2 no-access
This table contains gx2Dm200 specific parameters with nominal and current values.
     gx2Dm200AnalogEntry 1.3.6.1.4.1.1166.6.1.2.19.2.1 no-access
This list contains the analog parameters and descriptions.
         gx2Dm200AnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.19.2.1.1 integer read-only
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
         dm200labelOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.2 displaystring read-only
The value of this object provides the label of the Offset Monitor Analog parameter.
         dm200uomOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.3 displaystring read-only
The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter. The unit of measure for this parameter is dB
         dm200majorHighOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.4 float read-only
The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
         dm200majorLowOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.5 float read-only
The value of this object provides the Major Low alarm value of the Offset Monitor Power Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
         dm200minorHighOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.6 float read-only
The value of this object provides the Minor High alarm value of the Offset Monitor Power Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
         dm200minorLowOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.7 float read-only
The value of this object provides the Minor Low alarm value of the Offset Monitor Power Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
         dm200currentValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.8 float read-only
The value of this object provides the Current value of the Offset Monitor Power Analog parameter.
         dm200stateFlagOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.9 integer read-only
The value of this object provides the state of the Offset Monitor Power Analog parameter. (1-hidden 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         dm200minValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.10 float read-only
The value of this object provides the minimum value the Offset Monitor Power Analog parameter can achive.
         dm200maxValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.11 float read-only
The value of this object provides the maximum value the Offset Monitor Power Analog parameter can achive.
         dm200alarmStateOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.19.2.1.12 integer read-only
The value of this object provides the curent alarm state of the Offset Monitor Power Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
         dm200labelAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.13 displaystring read-only
The value of this object provides the label of the Attenuator Setting Current Analog parameter.
         dm200uomAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.14 displaystring read-only
The value of this object provides the Unit of Measure of the Attenuator Setting Analog parameter. The unit of measure for this parameter is dB
         dm200majorHighAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.15 float read-only
The value of this object provides the Major High alarm value of the Attenuator Setting Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
         dm200majorLowAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.16 float read-only
The value of this object provides the Major Low alarm value of the Attenuator Setting Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
         dm200minorHighAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.17 float read-only
The value of this object provides the Minor High alarm value of the Attenuator Setting Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
         dm200minorLowAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.18 float read-only
The value of this object provides the Minor Low alarm value of the Attenuator Setting Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
         dm200currentValueAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.19 float read-write
The value of this object provides the Current value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
         dm200stateFlagAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.20 integer read-only
The value of this object provides the state of the Attenuator Setting Analog parameter. (1-hidden 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         dm200minValueAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.21 float read-only
The value of this object provides the minimum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
         dm200maxValueAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.22 float read-only
The value of this object provides the maximum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
         dm200alarmStateAttenSetting 1.3.6.1.4.1.1166.6.1.2.19.2.1.23 integer read-only
The value of this object provides the curent alarm state of the Attenuator Setting Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
         dm200labelLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.24 displaystring read-only
The value of this object provides the label of the Laser Optical Power Analog parameter.
         dm200uomLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.25 displaystring read-only
The value of this object provides the Unit of Measure of the Laser Optical Power Analog parameter. The unit of measure for this parameter is dBm
         dm200majorHighLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.26 float read-only
The value of this object provides the Major High alarm value of the Laser Optical Power Analog parameter.
         dm200majorLowLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.27 float read-only
The value of this object provides the Major Low alarm value of the Laser Optical Power Analog parameter.
         dm200minorHighLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.28 float read-only
The value of this object provides the Minor High alarm value of the Laser Optical Power Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
         dm200minorLowLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.29 float read-only
The value of this object provides the Minor Low alarm value of the Laser Optical Power Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
         dm200currentValueLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.30 float read-only
The value of this object provides the Current value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
         dm200stateFlagLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.31 integer read-only
The value of this object provides the state of the Laser Optical Power Analog parameter. (1-hidden 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         dm200minValueLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.32 float read-only
The value of this object provides the minimum value the Laser Optical Power Analog parameter can achive.
         dm200maxValueLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.33 float read-only
The value of this object provides the maximum value the Laser Optical Power Analog parameter can achive.
         dm200alarmStateLaserPower 1.3.6.1.4.1.1166.6.1.2.19.2.1.34 integer read-only
The value of this object provides the curent alarm state of the Laser Optical Power Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
         dm200labelLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.35 displaystring read-only
The value of this object provides the label of the Laser Temperature Analog parameter.
         dm200uomLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.36 displaystring read-only
The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter. The unit of measure for this parameter is degrees C
         dm200majorHighLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.37 float read-only
The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter.
         dm200majorLowLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.38 float read-only
The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter.
         dm200minorHighLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.39 float read-only
The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter.
         dm200minorLowLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.40 float read-only
The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter.
         dm200currentValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.41 float read-only
The value of this object provides the Current value of the Laser Temperature Analog parameter.
         dm200stateFlagLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.42 integer read-only
The value of this object provides the state of the Laser Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         dm200minValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.43 float read-only
The value of this object provides the minimum value the Laser Temperature Analog parameter can achive.
         dm200maxValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.44 float read-only
The value of this object provides the maximum value the Laser Temperature Analog parameter can achive.
         dm200alarmStateLaserTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.45 integer read-only
The value of this object provides the curent alarm state of the Laser Temperature Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
         dm200labelLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.46 displaystring read-only
The value of this object provides the label of the Laser Bias Current Analog parameter.
         dm200uomLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.47 displaystring read-only
The value of this object provides the Unit of Measure of the Laser Bias Current Analog parameter. The unit of measure for this parameter is mA
         dm200majorHighLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.48 float read-only
The value of this object provides the Major High alarm value of the Laser Bias Current Analog parameter.
         dm200majorLowLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.49 float read-only
The value of this object provides the Major Low alarm value of the Laser Bias Current Analog parameter.
         dm200minorHighLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.50 float read-only
The value of this object provides the Minor High alarm value of the Laser Bias Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
         dm200minorLowLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.51 float read-only
The value of this object provides the Minor Low alarm value of the Laser Bias Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
         dm200currentValueLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.52 float read-only
The value of this object provides the Current value of the Laser Bias Current Analog parameter.
         dm200stateFlagLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.53 integer read-only
The value of this object provides the state of the Laser Bias Current Analog parameter. (1-hidden 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         dm200minValueLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.54 float read-only
The value of this object provides the minimum value the Laser Bias Current Analog parameter can achive.
         dm200maxValueLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.55 float read-only
The value of this object provides the maximum value the Laser Bias Current Analog parameter can achive.
         dm200alarmStateLaserCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.56 integer read-only
The value of this object provides the curent alarm state of the Laser Bias Current Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
         dm200labelTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.57 displaystring read-only
The value of this object provides the label of the TEC Current Analog parameter.
         dm200uomTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.58 displaystring read-only
The value of this object provides the Unit of Measure of the TEC Current Analog parameter. The unit of measure for this parameter is mA
         dm200majorHighTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.59 float read-only
The value of this object provides the Major High alarm value of the TEC Current Analog parameter.
         dm200majorLowTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.60 float read-only
The value of this object provides the Major Low alarm value of the TEC Current Analog parameter.
         dm200minorHighTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.61 float read-only
The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
         dm200minorLowTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.62 float read-only
The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
         dm200currentValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.63 float read-only
The value of this object provides the Current value of the TEC Current Analog parameter.
         dm200stateFlagTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.64 integer read-only
The value of this object provides the state of the TEC Current Analog parameter. (1-hidden 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         dm200minValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.65 float read-only
The value of this object provides the minimum value the TEC Current Analog parameter can achive.
         dm200maxValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.66 float read-only
The value of this object provides the maximum value the TEC Current Analog parameter can achive.
         dm200alarmStateTecCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.67 integer read-only
The value of this object provides the curent alarm state of the TEC Current Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
         dm200labelModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.68 displaystring read-only
The value of this object provides the label of the Module Temperature Analog parameter.
         dm200uomModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.69 displaystring read-only
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. The unit of measure for this parameter is degrees C
         dm200majorHighModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.70 float read-only
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter.
         dm200majorLowModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.71 float read-only
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter.
         dm200minorHighModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.72 float read-only
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter.
         dm200minorLowModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.73 float read-only
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter.
         dm200currentValueModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.74 float read-only
The value of this object provides the Current value of the Module Temperature Analog parameter.
         dm200stateFlagModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.75 integer read-only
The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         dm200minValueModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.76 float read-only
The value of this object provides the minimum value the Module Temperature Analog parameter can achive.
         dm200maxValueModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.77 float read-only
The value of this object provides the maximum value the Module Temperature Analog parameter can achive.
         dm200alarmStateModTemp 1.3.6.1.4.1.1166.6.1.2.19.2.1.78 integer read-only
The value of this object provides the curent alarm state of the Module Temperature Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
         dm200labelFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.79 displaystring read-only
The value of this object provides the label of the Fan Current Analog parameter.
         dm200uomFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.80 displaystring read-only
The value of this object provides the Unit of Measure of the Fan Current Analog parameter. The unit of measure for this parameter is mA
         dm200majorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.81 float read-only
The value of this object provides the Major High alarm value of the Fan Current Analog parameter.
         dm200majorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.82 float read-only
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter.
         dm200minorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.83 float read-only
The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
         dm200minorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.84 float read-only
The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
         dm200currentValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.85 float read-only
The value of this object provides the Current value of the Fan Current Analog parameter.
         dm200stateFlagFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.86 integer read-only
The value of this object provides the state of the Fan Current Analog parameter. (1-hidden 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         dm200minValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.87 float read-only
The value of this object provides the minimum value the Fan Current Analog parameter can achive.
         dm200maxValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.88 float read-only
The value of this object provides the maximum value the Fan Current Analog parameter can achive.
         dm200alarmStateFanCurrent 1.3.6.1.4.1.1166.6.1.2.19.2.1.89 integer read-only
The value of this object provides the curent alarm state of the Fan Current Analog parameter. Enumeration: 'majorLowAlarm': 2, 'noAlarm': 1, 'minorHighAlarm': 4, 'majorHighAlarm': 5, 'minorLowAlarm': 3, 'informational': 6.
 gx2Dm200DigitalTable 1.3.6.1.4.1.1166.6.1.2.19.3 no-access
This table contains gx2Dm200m specific parameters with nominal and current values.
     gx2Dm200DigitalEntry 1.3.6.1.4.1.1166.6.1.2.19.3.2 no-access
This list contains digital parameters and descriptions.
         gx2Dm200DigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.19.3.2.1 integer read-only
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
         dm200labelRfInput 1.3.6.1.4.1.1166.6.1.2.19.3.2.2 displaystring read-only
The value of this object provides the label of the RF Input Control Digital parameter.
         dm200enumRfInput 1.3.6.1.4.1.1166.6.1.2.19.3.2.3 displaystring read-only
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
         dm200valueRfInput 1.3.6.1.4.1.1166.6.1.2.19.3.2.4 integer read-write
The value of this object is the current value of the parameter. Enumeration: 'on': 2, 'off': 1.
         dm200stateflagRfInput 1.3.6.1.4.1.1166.6.1.2.19.3.2.5 integer read-only
The value of this object provides the state of the RF Input Control Digital parameter. (1-hidden 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         dm200labelOptOutput 1.3.6.1.4.1.1166.6.1.2.19.3.2.6 displaystring read-only
The value of this object provides the label of the Optical Output Control Digital parameter.
         dm200enumOptOutput 1.3.6.1.4.1.1166.6.1.2.19.3.2.7 displaystring read-only
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
         dm200valueOptOutput 1.3.6.1.4.1.1166.6.1.2.19.3.2.8 integer read-write
The value of this object is the current value of the parameter. Enumeration: 'on': 2, 'off': 1.
         dm200stateflagOptOutput 1.3.6.1.4.1.1166.6.1.2.19.3.2.9 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         dm200labelSbsControl 1.3.6.1.4.1.1166.6.1.2.19.3.2.10 displaystring read-only
The value of this object provides the label of the SBS Control Digital parameter.
         dm200enumSbsControl 1.3.6.1.4.1.1166.6.1.2.19.3.2.11 displaystring read-only
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
         dm200valueSbsControl 1.3.6.1.4.1.1166.6.1.2.19.3.2.12 integer read-write
The value of this object is the current value of the parameter. Enumeration: 'on': 2, 'off': 1.
         dm200stateflagSbsControl 1.3.6.1.4.1.1166.6.1.2.19.3.2.13 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         dm200labelFactoryDefault 1.3.6.1.4.1.1166.6.1.2.19.3.2.14 displaystring read-only
The value of this object provides the label of the Factory Default Digital parameter.
         dm200enumFactoryDefault 1.3.6.1.4.1.1166.6.1.2.19.3.2.15 displaystring read-only
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1..
         dm200valueFactoryDefault 1.3.6.1.4.1.1166.6.1.2.19.3.2.16 integer read-write
The value of this object is the current value of the parameter. Return value is meaningless Enumeration: 'on': 2, 'off': 1.
         dm200stateflagFactoryDefault 1.3.6.1.4.1.1166.6.1.2.19.3.2.17 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
 gx2Dm200StatusTable 1.3.6.1.4.1.1166.6.1.2.19.4 no-access
This table contains gx2Dm200 specific parameters with nominal and current values.
     gx2Dm200StatusEntry 1.3.6.1.4.1.1166.6.1.2.19.4.3 no-access
This list contains Status parameters and descriptions.
         gx2Dm200StatusTableIndex 1.3.6.1.4.1.1166.6.1.2.19.4.3.1 integer read-only
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
         dm200labelBoot 1.3.6.1.4.1.1166.6.1.2.19.4.3.2 displaystring read-only
The value of this object provides the label of the Boot Status Status parameter.
         dm200valueBoot 1.3.6.1.4.1.1166.6.1.2.19.4.3.3 integer read-only
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4.
         dm200stateflagBoot 1.3.6.1.4.1.1166.6.1.2.19.4.3.4 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         dm200labelFlash 1.3.6.1.4.1.1166.6.1.2.19.4.3.5 displaystring read-only
The value of this object provides the label of the Flash Status Status parameter.
         dm200valueFlash 1.3.6.1.4.1.1166.6.1.2.19.4.3.6 integer read-only
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4.
         dm200stateflagFlash 1.3.6.1.4.1.1166.6.1.2.19.4.3.7 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         dm200labelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.19.4.3.8 displaystring read-only
The value of this object provides the label of the Factory Data CRC Status parameter.
         dm200valueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.19.4.3.9 integer read-only
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4.
         dm200stateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.19.4.3.10 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         dm200labelLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.19.4.3.11 displaystring read-only
The value of this object provides the label of the Laser Data CRC Status parameter.
         dm200valueLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.19.4.3.12 integer read-only
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4.
         dm200stateflagLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.19.4.3.13 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         dm200labelAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.19.4.3.14 displaystring read-only
The value of this object provides the label of the Alarm Data Crc parameter.
         dm200valueAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.19.4.3.15 integer read-only
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4.
         dm200stateflagAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.19.4.3.16 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
         dm200labelRFInputStatus 1.3.6.1.4.1.1166.6.1.2.19.4.3.17 displaystring read-only
The value of this object provides the label of the Alarm Data Crc parameter.
         dm200valueRFInputStatus 1.3.6.1.4.1.1166.6.1.2.19.4.3.18 integer read-only
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). Enumeration: 'undetermined': 2, 'major': 5, 'ok': 1, 'warning': 3, 'critical': 6, 'minor': 4.
         dm200stateflagRFInputStatus 1.3.6.1.4.1.1166.6.1.2.19.4.3.19 integer read-only
The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). Enumeration: 'updateable': 3, 'hidden': 1, 'read-only': 2.
 gx2Dm200FactoryTable 1.3.6.1.4.1.1166.6.1.2.19.5 no-access
This table contains gx2Dm200 specific parameters with nominal and current values.
     gx2Dm200FactoryEntry 1.3.6.1.4.1.1166.6.1.2.19.5.4 no-access
This list contains Factory parameters and descriptions.
         gx2Dm200FactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.19.5.4.1 integer read-only
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
         dm200bootControlByte 1.3.6.1.4.1.1166.6.1.2.19.5.4.2 integer read-only
The value of this object indicates which bank the firmware is currently being boot from.
         dm200bootStatusByte 1.3.6.1.4.1.1166.6.1.2.19.5.4.3 integer read-only
This object indicates the status of the last boot. Bit 2 = Bank 0/1 Active (0 = Bank 0, 1 = Bank 1), Bit 1 = Bank 1 Fail and Bit 0 = Bank 0 Fail (0 = Pass, 1 = Fail)
         dm200bank1CRC 1.3.6.1.4.1.1166.6.1.2.19.5.4.4 integer read-only
This object provides the CRC code of bank 0. The display formate for the data is Hex.
         dm200bank2CRC 1.3.6.1.4.1.1166.6.1.2.19.5.4.5 integer read-only
This object provides the CRC code of bank 1.The display formate for the data is Hex.
         dm200prgEEPROMByte 1.3.6.1.4.1.1166.6.1.2.19.5.4.6 integer read-only
This object indicates if the EEPROM has been programmed
         dm200factoryCRC 1.3.6.1.4.1.1166.6.1.2.19.5.4.7 integer read-only
This object provides the CRC code for the Factory data.
         dm200calculateCRC 1.3.6.1.4.1.1166.6.1.2.19.5.4.8 integer read-only
This object indicates which of the Enums will have the CRC calculated. Enumeration: 'na': 2, 'alarm': 3, 'factory': 1.
         dm200hourMeter 1.3.6.1.4.1.1166.6.1.2.19.5.4.9 integer read-only
This object provides the hour meter reading of the module.
         dm200flashPrgCntA 1.3.6.1.4.1.1166.6.1.2.19.5.4.10 integer read-only
This object provides the number of times Bank 1 flash has been programmed.
         dm200flashPrgCntB 1.3.6.1.4.1.1166.6.1.2.19.5.4.11 integer read-only
This object provides the number of times Bank 1 flash has been programmed.
         dm200flashBankARev 1.3.6.1.4.1.1166.6.1.2.19.5.4.12 displaystring read-only
This object provides the revision of flash bank 0. The rev is 2 characters.
         dm200flashBankBRev 1.3.6.1.4.1.1166.6.1.2.19.5.4.13 displaystring read-only
This object provides the revision of flash bank 1. The rev is 2 characters.
   trapDM200ConfigChangeInteger 1.3.6.1.4.1.1166.6.1.2.190.1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
   trapDM200ConfigChangeDisplayString 1.3.6.1.4.1.1166.6.1.2.190.2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
   trapDM200fanCurrentAlarm 1.3.6.1.4.1.1166.6.1.2.190.3
This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
   trapDM200ModuleTempAlarm 1.3.6.1.4.1.1166.6.1.2.190.4
This trap is issued when the Module Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
   trapDM200omiOffsetAlarm 1.3.6.1.4.1.1166.6.1.2.190.5
This trap is issued when the OMI Offset goes out of range.
   trapDM200tecCurrentAlarm 1.3.6.1.4.1.1166.6.1.2.190.6
This trap is issued when the TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
   trapDM200LaserCurrentAlarm 1.3.6.1.4.1.1166.6.1.2.190.7
This trap is issued when the Laser Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
   trapDM200LaserTempAlarm 1.3.6.1.4.1.1166.6.1.2.190.8
This trap is issued when the Laser Temp parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
   trapDM200LaserPowerAlarm 1.3.6.1.4.1.1166.6.1.2.190.9
This trap is issued when the Laser Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
   trapDM200FlashAlarm 1.3.6.1.4.1.1166.6.1.2.190.10
This trap is issued when the Laser Modules detects an error during Flash memory operations.
   trapDM200BankBootAlarm 1.3.6.1.4.1.1166.6.1.2.190.11
This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1.
   trapDM200AlarmDataCRCAlarm 1.3.6.1.4.1.1166.6.1.2.190.12
This trap is issued when the Alarm Data CRC is incorrect.
   trapDM200FactoryDataCRCAlarm 1.3.6.1.4.1.1166.6.1.2.190.13
This trap is issued when the Factory Data CRC is incorrect.
   trapDM200CalDataCRCAlarm 1.3.6.1.4.1.1166.6.1.2.190.14
This trap is issued when the Cal Data CRC is incorrect.
   trapDM200ResetFacDefault 1.3.6.1.4.1.1166.6.1.2.190.15
This trap is issued when the DM200 resets to factory defaults
   trapDM200UserRFOffAlarm 1.3.6.1.4.1.1166.6.1.2.190.16
This trap is issued when the the User RF is turned off.
   trapDM200UserOpticalOffAlarm 1.3.6.1.4.1.1166.6.1.2.190.17
This trap is issued when the User Optical Power is turned off.
   trapDM200UserSBSOffAlarm 1.3.6.1.4.1.1166.6.1.2.190.18
This trap is issued when the User SBS is turned off.
   trapDM200RFInputAlarm 1.3.6.1.4.1.1166.6.1.2.190.19
This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
   trapDM200RFOverloadAlarm 1.3.6.1.4.1.1166.6.1.2.190.20
This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.