NNCEXTE3-MIB: View SNMP OID List / Download MIB

VENDOR: NEWBRIDGE NETWORKS CORPORATION


 Home MIB: NNCEXTE3-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 nncExtE3 1.3.6.1.4.1.123.3.40
This module contains definitions for Newbridge extensions to E3 objects. It is used as a supplement to rfc1407.
       nncExtE3Objects 1.3.6.1.4.1.123.3.40.1
           nncExtE3Current15MinTable 1.3.6.1.4.1.123.3.40.1.1 no-access
NNC Extension to dsx3CurrentTable.
               nncExtE3Current15MinEntry 1.3.6.1.4.1.123.3.40.1.1.1 no-access
An entry in nncExtE3Current15MinTable.
                   nncExtE3Current15MinESs 1.3.6.1.4.1.123.3.40.1.1.1.1 gauge32 read-only
The counter associated with the number of Path Errored Seconds encountered by a E3 interface in the current 15 minute interval. This counts the seconds containing one or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
                   nncExtE3Current15MinSESs 1.3.6.1.4.1.123.3.40.1.1.1.2 gauge32 read-only
The counter associated with the number of Path Severely Errored Seconds encountered by a E3 interface in the current 15 minute interval. This counts the seconds containing 34 or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
                   nncExtE3Current15MinSEFs 1.3.6.1.4.1.123.3.40.1.1.1.3 gauge32 read-only
The counter associated with the number of Path Severely Errored Frames encountered by a E3 interface in the current 15 minute interval. This counts framing pattern errors. In Direct cell mapping mode, this is the count of frames with errored FA1/FA2 bytes in the G.832 overhead. In PLCP mode, this is the count of frames with an errored G.751 Frame Alignment byte.
           nncExtE3Interval15MinTable 1.3.6.1.4.1.123.3.40.1.2 no-access
NNC Extension to dsx3IntervalTable.
               nncExtE3Interval15MinEntry 1.3.6.1.4.1.123.3.40.1.2.1 no-access
An entry in nncExtE3Interval15MinTable.
                   nncExtE3Interval15MinNumber 1.3.6.1.4.1.123.3.40.1.2.1.1 integer32 no-access
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
                   nncExtE3Interval15MinESs 1.3.6.1.4.1.123.3.40.1.2.1.2 gauge32 read-only
The counter associated with the number of Path Errored Seconds encountered by a E3 interface in one of the previous 15 minute intervals. This counts the seconds containing one or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
                   nncExtE3Interval15MinSESs 1.3.6.1.4.1.123.3.40.1.2.1.3 gauge32 read-only
The counter associated with the number of Path Severely Errored Seconds encountered by a E3 interface in one of the previous 15 minute intervals. This counts the seconds containing 34 or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
                   nncExtE3Interval15MinSEFs 1.3.6.1.4.1.123.3.40.1.2.1.4 gauge32 read-only
The counter associated with the number of Path Severely Errored Frames encountered by a E3 interface in one of the previous 15 minute intervals. This counts framing pattern errors. In Direct cell mapping mode, this is the count of frames with errored FA1/FA2 bytes in the G.832 overhead. In PLCP mode, this is the count of frames with an errored G.751 Frame Alignment byte.
           nncExtE3Total24HrTable 1.3.6.1.4.1.123.3.40.1.3 no-access
NNC Extension to dsx3TotalTable.
               nncExtE3Total24HrEntry 1.3.6.1.4.1.123.3.40.1.3.1 no-access
An entry in nncExtE3Total24HrTable.
                   nncExtE3Total24HrESs 1.3.6.1.4.1.123.3.40.1.3.1.1 gauge32 read-only
The counter associated with the number of Path Errored Seconds encountered by a E3 interface in the previous 24 hours interval. This counts the seconds containing one or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
                   nncExtE3Total24HrSESs 1.3.6.1.4.1.123.3.40.1.3.1.2 gauge32 read-only
The counter associated with the number of Path Severely Errored Seconds encountered by a E3 interface in the previous 24 hours interval. This counts the seconds containing 34 or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
                   nncExtE3Total24HrSEFs 1.3.6.1.4.1.123.3.40.1.3.1.3 gauge32 read-only
The counter associated with the number of Path Severely Errored Frames encountered by a E3 interface in the previous 24 hours interval. This counts framing pattern errors. In Direct cell mapping mode, this is the count of frames with errored FA1/FA2 bytes in the G.832 overhead. In PLCP mode, this is the count of frames with an errored G.751 Frame Alignment byte.
           nncExtE3FarEndCurrent15MinTable 1.3.6.1.4.1.123.3.40.1.4 no-access
NNC Extension to dsx3FarEndCurrentTable.
               nncExtE3FarEndCurrent15MinEntry 1.3.6.1.4.1.123.3.40.1.4.1 no-access
An entry in nncExtE3FarEndCurrent15MinTable.
                   nncExtE3FarEndCurrent15MinFEBEs 1.3.6.1.4.1.123.3.40.1.4.1.1 gauge32 read-only
The counter associated with the number of Far End Block Errors encountered by a E3 interface in the current 15 minute interval. This is the count of received FEBEs. This counter will not increment while failure defects are present. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
                   nncExtE3FarEndCurrent15MinESs 1.3.6.1.4.1.123.3.40.1.4.1.2 gauge32 read-only
The counter associated with the number of Far End Path Errored Seconds encountered by a E3 interface in the current 15 minute interval. This counts the seconds containing one or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
                   nncExtE3FarEndCurrent15MinSESs 1.3.6.1.4.1.123.3.40.1.4.1.3 gauge32 read-only
The counter associated with the number of Far End Path Severely Errored Seconds encountered by a E3 interface in the current 15 minute interval. This counts the seconds containing 34 or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
           nncExtE3FarEndInterval15MinTable 1.3.6.1.4.1.123.3.40.1.5 no-access
NNC Extension to dsx3FarEndIntervalTable.
               nncExtE3FarEndInterval15MinEntry 1.3.6.1.4.1.123.3.40.1.5.1 no-access
An entry in nncExtE3FarEndInterval15MinTable.
                   nncExtE3FarEndInterval15MinNumber 1.3.6.1.4.1.123.3.40.1.5.1.1 integer32 no-access
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
                   nncExtE3FarEndInterval15MinFEBEs 1.3.6.1.4.1.123.3.40.1.5.1.2 gauge32 read-only
The counter associated with the number of Far End Block Errors encountered by a E3 interface in one of the previous 15 minute intervals. This is the count of received FEBEs. This counter will not increment while failure defects are present. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
                   nncExtE3FarEndInterval15MinESs 1.3.6.1.4.1.123.3.40.1.5.1.3 gauge32 read-only
The counter associated with the number of Far End Path Errored Seconds encountered by a E3 interface in one of the previous 15 minute intervals. This counts the seconds containing one or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
                   nncExtE3FarEndInterval15MinSESs 1.3.6.1.4.1.123.3.40.1.5.1.4 gauge32 read-only
The counter associated with the number of Far End Path Severely Errored Seconds encountered by a E3 interface in one of the previous 15 minute intervals. This counts the seconds containing 34 or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
           nncExtE3FarEndTotal24HrTable 1.3.6.1.4.1.123.3.40.1.6 no-access
NNC Extension to dsx3FarEndTotalTable.
               nncExtE3FarEndTotal24HrEntry 1.3.6.1.4.1.123.3.40.1.6.1 no-access
An entry in nncExtE3FarEndTotal24HrTable.
                   nncExtE3FarEndTotal24HrFEBEs 1.3.6.1.4.1.123.3.40.1.6.1.1 gauge32 read-only
The counter associated with the number of Far End Block Errors encountered by a E3 interface in the previous 24 hours interval. This is the count of received FEBEs. This counter will not increment while failure defects are present. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
                   nncExtE3FarEndTotal24HrESs 1.3.6.1.4.1.123.3.40.1.6.1.2 gauge32 read-only
The counter associated with the number of Far End Path Errored Seconds encountered by a E3 interface in the previous 24 hours interval. This counts the seconds containing one or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
                   nncExtE3FarEndTotal24HrSESs 1.3.6.1.4.1.123.3.40.1.6.1.3 gauge32 read-only
The counter associated with the number of Far End Path Severely Errored Seconds encountered by a E3 interface in the previous 24 hours interval. This counts the seconds containing 34 or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode.
       nncExtE3Traps 1.3.6.1.4.1.123.3.40.2
       nncExtE3Groups 1.3.6.1.4.1.123.3.40.3
           nncExtE3Current15MinGroup 1.3.6.1.4.1.123.3.40.3.1
Collection of objects providing 15 minute current statistics for E3 interface.
           nncExtE3Interval15MinGroup 1.3.6.1.4.1.123.3.40.3.2
Collection of objects providing 15 minute interval statistics for E3 interface.
           nncExtE3Total24HrGroup 1.3.6.1.4.1.123.3.40.3.3
Collection of objects providing previous 24 hours statistics for E3 interface.
           nncExtE3FarEndCurrent15MinGroup 1.3.6.1.4.1.123.3.40.3.4
Collection of objects providing 15 minute current statistics for E3 interface.
           nncExtE3FarEndInterval15MinGroup 1.3.6.1.4.1.123.3.40.3.5
Collection of objects providing 15 minute interval statistics for E3 interface.
           nncExtE3FarEndTotal24HrGroup 1.3.6.1.4.1.123.3.40.3.6
Collection of objects providing previous 24 hours statistics for E3 interface.
       nncExtE3Compliances 1.3.6.1.4.1.123.3.40.4
           nncExtE3Compliance 1.3.6.1.4.1.123.3.40.4.1
The compliance statement for Newbridge E3 interfaces.