Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 microwave_radio 1.3.6.1.4.1.2281
           genEquip 1.3.6.1.4.1.2281.10
                 genEquipUnit 1.3.6.1.4.1.2281.10.1
                 genEquipRFU 1.3.6.1.4.1.2281.10.5
                     genEquipRfuStatusTable 1.3.6.1.4.1.2281.10.5.1 no-access
This table indicates the RFU Status Data.
                         genEquipRfuStatusEntry 1.3.6.1.4.1.2281.10.5.1.1 no-access
Entry containing the data of the RFU.
                             genEquipRfuStatusId 1.3.6.1.4.1.2281.10.5.1.1.1 rfuid read-only
This value indicates an index of a specific RFU
                             genEquipRfuStatusRxLevel 1.3.6.1.4.1.2281.10.5.1.1.2 integer read-only
This value indicates the RFU Receive Level Status.
                             genEquipRfuStatusTxLevel 1.3.6.1.4.1.2281.10.5.1.1.3 integer read-only
This value indicates the RFU Transmit Level Status.
                             genEquipRfuStatusTemperature 1.3.6.1.4.1.2281.10.5.1.1.4 integer read-only
This value indicates the RFU temperature. The value depends on the represented measurement system. with genEquipUnitMeasurementSystem parameter.
                             genEquipRfuStatusRunningVersion 1.3.6.1.4.1.2281.10.5.1.1.5 displaystring read-only
This value indicates the running SW version on the RFU.
                             genEquipRfuStatusRFUType 1.3.6.1.4.1.2281.10.5.1.1.6 integer read-only
The different types of the supported RFUs Enumeration: 'rfu-c': 38, 'rfu-a': 42, 'rfu-d': 43, 'unknown': 2, 'rfu-h': 39, 'rfu-1500hp': 34, 'rfu-1500sp': 40, 'rfu-1500p': 32, 'rfu-hp': 41.
                             genEquipRfuStatusRFUGrade 1.3.6.1.4.1.2281.10.5.1.1.7 rfugrade read-only
The grade of the RFU
                             genEquipRfuStatusTxRxFreqSeparation 1.3.6.1.4.1.2281.10.5.1.1.8 integer read-only
Tx to Rx frequency separation (MHz), For some RFUs the user cannot set the Tx and Rx frequencies separately (one of them affects the other one's value).
                             genEquipRfuStatusRFUMode 1.3.6.1.4.1.2281.10.5.1.1.9 integer read-only
IF combining parameter - The mode of the RFU Enumeration: 'main': 2, 'diversity': 3, 'combined': 4.
                             genEquipRfuStatusRxLevelDiversity 1.3.6.1.4.1.2281.10.5.1.1.10 integer read-only
IF combining parameter - The Rx Diversity level (dBm)
                             genEquipRfuStatusRxLevelCombined 1.3.6.1.4.1.2281.10.5.1.1.11 integer read-only
IF combining parameter - The Rx Combined level (dBm)
                             genEquipRfuStatusAutoDelayCalStatus 1.3.6.1.4.1.2281.10.5.1.1.12 integer read-only
IF combining parameter - the automatic delay calibration status. Supported only for specific RFUs. Enumeration: 'error': 4, 'no-action': 2, 'pass': 3.
                             genEquipRfuStatusRFUSerialNumber 1.3.6.1.4.1.2281.10.5.1.1.13 displaystring read-only
RFU Serial number.
                             genEquipRfuStatusRFUPartNumber 1.3.6.1.4.1.2281.10.5.1.1.14 displaystring read-only
RFU Part number.
                             genEquipRfuStatusRFUmateCarrier 1.3.6.1.4.1.2281.10.5.1.1.15 integer read-only
The returned value indicates the slot number of the 'copartner RFU-D carrier'. The returned value will be '-1' when the RFU is not RFU-D, or if the 'copartner RFU-D' carrier is not found.
                             genEquipRfuStatusRFUMaxTxFreq 1.3.6.1.4.1.2281.10.5.1.1.16 integer read-only
The maximum Tx frequency of the RFU that is allowed by the RFU.
                             genEquipRfuStatusRFUMinTxFreq 1.3.6.1.4.1.2281.10.5.1.1.17 integer read-only
The minimum Tx frequency of the RFU that is allowed by the RFU.
                             genEquipRfuStatusRFUMaxRxFreq 1.3.6.1.4.1.2281.10.5.1.1.18 integer read-only
The maximum Rx frequency of the RFU that is allowed by the RFU.
                             genEquipRfuStatusRFUMinRxFreq 1.3.6.1.4.1.2281.10.5.1.1.19 integer read-only
The minimum Rx frequency of the RFU that is allowed by the RFU.
                             genEquipRfuStatusInstallation 1.3.6.1.4.1.2281.10.5.1.1.20 integer read-only
Returns 'all-indoor' or 'split' according to the RFU installation. Enumeration: 'all-indoor': 1, 'split-mount': 0.
                             genEquipRfuStatusDataSciErrors 1.3.6.1.4.1.2281.10.5.1.1.21 integer read-only
Data Sci Errors
                             genEquipRfuStatusDeviceError 1.3.6.1.4.1.2281.10.5.1.1.22 integer read-only
Status Device Error
                             genEquipRfuStatusBand 1.3.6.1.4.1.2281.10.5.1.1.23 integer read-only
The Band of the RF-Module in GHz Enumeration: 'band-13': 10, 'band-6L-6H': 13, 'band-15': 9, 'unknown': 0, 'band-18': 2, 'band-10dot5-11': 11, 'band-38': 6, 'band-29': 7, 'band-28': 5, 'band-32': 14, 'band-23': 3, 'band-31': 8, 'band-7-8': 12, 'band-26': 4.
                             genEquipRfuStatusPATemp 1.3.6.1.4.1.2281.10.5.1.1.24 integer read-only
The measured temperature in celsius of the PA (Power Amplifier) of the RF module
                             genEquipRfuStatusTxMute 1.3.6.1.4.1.2281.10.5.1.1.25 offon read-only
The mute status, whether it is on (mute) or off (un-mute) of the RF-Module
                             genEquipRfuStatusMinTxLevel 1.3.6.1.4.1.2281.10.5.1.1.26 integer read-only
The minimum feasible TX signal level (TSL) in dBm of the RF-Module
                             genEquipRfuStatusMaxTxLevel 1.3.6.1.4.1.2281.10.5.1.1.27 integer read-only
The maximum feasible TX signal level (TSL) in dBm of the RF-Module
                             genEquipRfuStatusMinBW 1.3.6.1.4.1.2281.10.5.1.1.28 integer read-only
The minimum supported bandwidth in KHz of the RF-Module
                             genEquipRfuStatusMaxBW 1.3.6.1.4.1.2281.10.5.1.1.29 integer read-only
The maximum supported bandwidth in KHz of the RF-Module
                             genEquipRfuStatusCommunication 1.3.6.1.4.1.2281.10.5.1.1.30 downup read-only
The communication status between the host and the RFU
                             genEquipRfuCfgATPCOverrideTimerState 1.3.6.1.4.1.2281.10.5.1.1.31 integer read-only
Returns the state of the ATPC 'override timer', whether it is regular or expired Enumeration: 'expired': 1, 'normal': 0.
                             genEquipRfuStatusIfCombSupport 1.3.6.1.4.1.2281.10.5.1.1.32 supportednotsupported read-only
Indicates if the IF-Combiner function is supported
                             genEquipRfuStatusMinRxLevel 1.3.6.1.4.1.2281.10.5.1.1.33 integer read-only
The minimum feasible RX signal level (RSL) in dBm of the RF-Module
                             genEquipRfuStatusMaxRxLevel 1.3.6.1.4.1.2281.10.5.1.1.34 integer read-only
The maximum feasible RX signal level (RSL) in dBm of the RF-Module
                     genEquipRfuCfgTable 1.3.6.1.4.1.2281.10.5.2 no-access
This table indicates the RFU Configuration.
                         genEquipRfuCfgEntry 1.3.6.1.4.1.2281.10.5.2.1 no-access
This table indicates the RFU Configuration.
                             genEquipRfuCfgId 1.3.6.1.4.1.2281.10.5.2.1.1 rfuid read-only
This value indicates an index of a specific RFU
                             genEquipRfuCfgMaxTxLevel 1.3.6.1.4.1.2281.10.5.2.1.2 integer read-write
This value indicates the RFU Maximum Transmit Level Configuration.
                             genEquipRfuCfgTxFreq 1.3.6.1.4.1.2281.10.5.2.1.3 integer read-write
Tx Frequency configuration (Mhz)
                             genEquipRfuCfgRxFreq 1.3.6.1.4.1.2281.10.5.2.1.4 integer read-write
Rx Frequency configuration (Mhz)
                             genEquipRfuCfgATPCAdmin 1.3.6.1.4.1.2281.10.5.2.1.5 enabledisable read-write
ATPC configuration - Admin mode Possible values: - enable(2) - disable(3)
                             genEquipRfuCfgATPCRefRSL 1.3.6.1.4.1.2281.10.5.2.1.6 integer read-write
ATPC configuration - reference RSL level (dBm)
                             genEquipRfuCfgMuteTx 1.3.6.1.4.1.2281.10.5.2.1.7 muteonoff read-write
The required TX mute status of the RF-Module
                             genEquipRfuCfgRSLConnSrc 1.3.6.1.4.1.2281.10.5.2.1.8 integer read-write
IF combining - RFU RSL (Received Signal Level) connector source Enumeration: 'main': 2, 'diversity': 3.
                             genEquipRfuCfgDelayCal 1.3.6.1.4.1.2281.10.5.2.1.9 integer read-write
IF combining - Delay calibration
                             genEquipRfuCfgLoopback 1.3.6.1.4.1.2281.10.5.2.1.10 integer read-write
RFU RF loopback command Enumeration: 'towardsSystem': 1, 'off': 0.
                             genEquipRfuCfgLogAdmin 1.3.6.1.4.1.2281.10.5.2.1.11 enabledisable read-write
RFU internal log file admin Possible values: - enable(2) - disable(3)
                             genEquipRfuCfgClearComDeviceError 1.3.6.1.4.1.2281.10.5.2.1.12 offon read-write
Clear Com device Error.
                             genEquipRfuCfgGreenModeAdmin 1.3.6.1.4.1.2281.10.5.2.1.13 enabledisable read-write
Enables/disables RFU green mode. This mode will minimize power consumption while ensuring the highest transmission power possible to get an RSL not higher than defined in the reference level genEquipRfuCfgGreenModeReferenceLevel
                             genEquipRfuCfgGreenModeReferenceLevel 1.3.6.1.4.1.2281.10.5.2.1.14 integer read-write
RSL reference level (in dB) for green mode operation
                             genEquipRfuCfgATPCOverrideTxLevel 1.3.6.1.4.1.2281.10.5.2.1.15 integer read-write
This parameter configures the default transmission signal level in case of ATPC override due to expiration of maximum power timer as defined in genEquipRfuCfgATPCOverrideTimeout.
                             genEquipRfuCfgATPCOverrideTimeout 1.3.6.1.4.1.2281.10.5.2.1.16 integer read-write
This parameter configures the timer to be counted while in ATPC in case of maximum power transmission. If this timer expires, the system will transmit at a default level defined in genEquipRfuCfgATPCOverrideTxLevel
                             genEquipRfuCfgATPCOverrideTimerCounter 1.3.6.1.4.1.2281.10.5.2.1.17 integer read-only
This parameter shows the time left in the timer defined by genEquipRfuCfgATPCOverrideTxLevel
                             genEquipRfuCfgATPCOverrideTimerCancel 1.3.6.1.4.1.2281.10.5.2.1.18 offon read-write
Setting this parameter to ON will cancel the ATPC override mode. This will only be effective while in this mode i.e. the system had been transmitting at maximum power for a time longer than defined in genEquipRfuCfgATPCOverrideTxLevel and now is transmitting at the default level defined in genEquipRfuCfgATPCOverrideTxLevel. Following execution, the system will go back to normal ATPC operating mode
                     genEquipRfuUploadTable 1.3.6.1.4.1.2281.10.5.3 no-access
RFU Upload Data table.
                         genEquipRfuUploadEntry 1.3.6.1.4.1.2281.10.5.3.1 no-access
Entry containing the data of the RFU.
                             genEquipRfuUploadId 1.3.6.1.4.1.2281.10.5.3.1.1 radioid read-only
This value indicates an index of a specific RFU
                             genEquipRfuUploadSwCommand 1.3.6.1.4.1.2281.10.5.3.1.2 integer read-write
This value initiates SW upload to the RFU. Enumeration: 'uploadSW': 1, 'noOperation': 2.
                             genEquipRfuUploadSwStatus 1.3.6.1.4.1.2281.10.5.3.1.3 integer read-only
This value indicates the status of the SW load operation on the RFU. Enumeration: 'loadSendBlock': 3, 'loadStart': 2, 'noLoad': 0, 'loadDone': 5, 'loadError': 1.
                             genEquipRfuUploadCounter 1.3.6.1.4.1.2281.10.5.3.1.4 integer read-only
This parameter shows the progress (in blocks) of RFU software download
                     genEquipRFUNG 1.3.6.1.4.1.2281.10.5.4
                         genEquipRfuSwInstallTable 1.3.6.1.4.1.2281.10.5.4.2 no-access
RFU software managemet install configuration.
                             genEquipRfuSwInstallEntry 1.3.6.1.4.1.2281.10.5.4.2.1 no-access
RFU software managemet install configuration.
                                 genEquipRfuSwInstallIfIndex 1.3.6.1.4.1.2281.10.5.4.2.1.1 integer read-only
RFU ifIndex
                                 genEquipRfuSwInstallOperation 1.3.6.1.4.1.2281.10.5.4.2.1.2 integer read-write
RFU software installation operation to be performed. Enumeration: 'install-existing-version': 2, 'update-version-from-bundle': 1, 'no-operation': 0, 'abort-timer': 3.
                                 genEquipRfuSwInstallTimedInstallation 1.3.6.1.4.1.2281.10.5.4.2.1.3 noyes read-write
Determines whether the installation will be carried out after a configured timer.
                                 genEquipRfuSwInstallTimer 1.3.6.1.4.1.2281.10.5.4.2.1.4 integer read-write
Timer for timed installations
                         genEquipRfuInstalledVersionsTable 1.3.6.1.4.1.2281.10.5.4.3 no-access
RFU software managemet installed versuion.
                             genEquipRfuInstalledVersionsEntry 1.3.6.1.4.1.2281.10.5.4.3.1 no-access
RFU software managemet installed version.
                                 genEquipRfuInstalledVersionsIfIndex 1.3.6.1.4.1.2281.10.5.4.3.1.1 integer read-only
RFU ifIndex
                                 genEquipRfuInstalledVersionsDSP 1.3.6.1.4.1.2281.10.5.4.3.1.2 displaystring read-only
RFU version DSP.
                                 genEquipRfuInstalledVersionsConfigurations 1.3.6.1.4.1.2281.10.5.4.3.1.3 displaystring read-only
Configuration tables.
                                 genEquipRfuInstalledVersionsConstants 1.3.6.1.4.1.2281.10.5.4.3.1.4 displaystring read-only
Constant tables
                                 genEquipRfuInstalledVersionsScripts 1.3.6.1.4.1.2281.10.5.4.3.1.5 displaystring read-only
RFU scripts
                                 genEquipRfuInstalledVersionsFirmware 1.3.6.1.4.1.2281.10.5.4.3.1.6 displaystring read-only
Firmware
                         genEquipRfuSwStatusTable 1.3.6.1.4.1.2281.10.5.4.4 no-access
RFU software managemet installed status.
                             genEquipRfuSwStatusEntry 1.3.6.1.4.1.2281.10.5.4.4.1 no-access
RFU software managemet installed status.
                                 genEquipRfuSwStatusIfIndex 1.3.6.1.4.1.2281.10.5.4.4.1.1 integer read-only
RFU ifIndex
                                 genEquipRfuSwStatusCurrentState 1.3.6.1.4.1.2281.10.5.4.4.1.2 rfusoftwareinstallstat read-only
Current state of the install operation.
                                 genEquipRfuSwStatusProgress 1.3.6.1.4.1.2281.10.5.4.4.1.3 integer read-only
Progress of the current install operation in percentage.
                         genEquipRfuRunningVersionsTable 1.3.6.1.4.1.2281.10.5.4.5 no-access
RFU software managemet rinning versions.
                             genEquipRfuRunningVersionsEntry 1.3.6.1.4.1.2281.10.5.4.5.1 no-access
RFU software managemet running versions.
                                 genEquipRfuRunningVersionsIfIndex 1.3.6.1.4.1.2281.10.5.4.5.1.1 integer read-only
RFU ifIndex
                                 genEquipRfuRunningVersionsDSP 1.3.6.1.4.1.2281.10.5.4.5.1.2 displaystring read-only
DSP.
                                 genEquipRfuRunningVersionsConfigurations 1.3.6.1.4.1.2281.10.5.4.5.1.3 displaystring read-only
Configuration tables.
                                 genEquipRfuRunningVersionsConstants 1.3.6.1.4.1.2281.10.5.4.5.1.4 displaystring read-only
Constant tables.
                                 genEquipRfuRunningVersionsScripts 1.3.6.1.4.1.2281.10.5.4.5.1.5 displaystring read-only
RFU scripts.
                                 genEquipRfuRunningVersionsFirmware 1.3.6.1.4.1.2281.10.5.4.5.1.6 displaystring read-only
Firmware.
                         genEquipRfuAvailableVersionsTable 1.3.6.1.4.1.2281.10.5.4.6 no-access
RFU software managemet available versions.
                             genEquipRfuAvailableVersionsEntry 1.3.6.1.4.1.2281.10.5.4.6.1 no-access
RFU software managemet available versions.
                                 genEquipRfuAvailableVersionsRfuType 1.3.6.1.4.1.2281.10.5.4.6.1.1 rfumajortype read-only
RFU Type
                                 genEquipRfuAvailableVersionsDSP 1.3.6.1.4.1.2281.10.5.4.6.1.2 displaystring read-only
DSP.
                                 genEquipRfuAvailableVersionsConfigurations 1.3.6.1.4.1.2281.10.5.4.6.1.3 displaystring read-only
Configuration tables.
                                 genEquipRfuAvailableVersionsConstants 1.3.6.1.4.1.2281.10.5.4.6.1.4 displaystring read-only
Constant tables.
                                 genEquipRfuAvailableVersionsScripts 1.3.6.1.4.1.2281.10.5.4.6.1.5 displaystring read-only
RFU scripts.
                                 genEquipRfuAvailableVersionsFirmware 1.3.6.1.4.1.2281.10.5.4.6.1.6 displaystring read-only
Firmware.
                 genEquipRadio 1.3.6.1.4.1.2281.10.7
                     genEquipRadioStatusTable 1.3.6.1.4.1.2281.10.7.1 no-access
Radio status table
                         genEquipRadioStatusEntry 1.3.6.1.4.1.2281.10.7.1.1 no-access
Radio status table
                             genEquipRadioStatusRadioId 1.3.6.1.4.1.2281.10.7.1.1.1 radioid read-only
This value is the radio ID that serves as the table Index.
                             genEquipRadioStatusMSE 1.3.6.1.4.1.2281.10.7.1.1.2 integer read-only
MSE (Mean Square Error) of the Rx signal (measured in dB * 100). -9900 value (-99.00 dB) means that the signal is not locked. ~ -3500 value (-35.00 dB) is a good MSE.
                             genEquipRadioStatusDefectedBlocks 1.3.6.1.4.1.2281.10.7.1.1.3 integer read-only
The number of counted defective radio blocks.
                             genEquipRadioStatusBER 1.3.6.1.4.1.2281.10.7.1.1.4 thresholdexponent read-only
The measured BER (Bit Error Rate) level of the modem.
                             genEquipRadioStatusXPI 1.3.6.1.4.1.2281.10.7.1.1.5 integer read-only
XPI (Cross Polar Interference) level measured by the modem.
                             genEquipRadioStatusXPICEnabled 1.3.6.1.4.1.2281.10.7.1.1.6 enabledisablesmi2 read-only
This parameter indicates whether an XPIC script is currently loaded.
                     genEquipRadioCfgTable 1.3.6.1.4.1.2281.10.7.2 no-access
Radio Configuration table.
                         genEquipRadioCfgEntry 1.3.6.1.4.1.2281.10.7.2.1 no-access
Radio Configuration table.
                             genEquipRadioCfgRadioId 1.3.6.1.4.1.2281.10.7.2.1.1 radioid read-only
This value is the radio ID that serves as this table Index
                             genEquipRadioCfgLinkId 1.3.6.1.4.1.2281.10.7.2.1.2 integer read-write
Radio configuration link ID
                             genEquipRadioCfgMACHeaderCompression 1.3.6.1.4.1.2281.10.7.2.1.3 enabledisable read-write
The Admin state of the MAC header compression.
                             genEquipRadioCfgClearCounters 1.3.6.1.4.1.2281.10.7.2.1.4 offon read-write
Setting this parameter to ON will clear the radio counters.
                             genEquipRadioCfgIfLoopback 1.3.6.1.4.1.2281.10.7.2.1.5 integer read-write
The administrative state of the IF loopback. Enumeration: 'towardsSystem': 1, 'off': 0.
                             genEquipRadioCfgExcessiveBERThreshold 1.3.6.1.4.1.2281.10.7.2.1.6 thresholdexponent read-write
The BER threshold that when exceeded will be considered as 'Excessive BER'.
                             genEquipRadioCfgSignalDegradeThreshold 1.3.6.1.4.1.2281.10.7.2.1.7 thresholdexponent read-write
The BER (Bit Error Rate) threshold that when exceeded will be considered as 'Signal Degrade'.
                             genEquipRadioCfgRadioAdmin 1.3.6.1.4.1.2281.10.7.2.1.8 enabledisable read-write
Radio Admin state (Enable,Disable) can be used in ifTable::ifAdminStatus
                             genEquipRadioCfgRadioOperationalStatus 1.3.6.1.4.1.2281.10.7.2.1.9 downup read-only
The operational status of the radio interface.
                             genEquipRadioCfgRadioTrafficPriorityScheme 1.3.6.1.4.1.2281.10.7.2.1.10 integer read-write
this parameter configures the relative priority of different traffic streams. High-tdm-over-high-ethernet gives priorities as follows: (1) TDM high priority (2) Ethernet high priority (3) TDM low priority (4) Etherenet low priority. High-Ethernet-over-tdm gives priorities as follows: (1) Ethernet high priority (2) TDM high priority (3) TDM low priority (4) Etherenet low priority. Tdm-over-ethernet gives priorities as follows: (1) TDM high priority (2) TDM low priority (3) Ethernet Enumeration: 'high-tdm-over-high-ethernet': 2, 'high-tdm-over-ethernet': 0, 'high-ethernet-over-tdm': 1.
                             genEquipRadioCfgRadioHiPriorityEthernetBW 1.3.6.1.4.1.2281.10.7.2.1.11 integer read-write
this parameter configures the amount of bandwith reserved for high-priority Ethernet. It must be a number in resolution of 2.048 Mbit/s for E1 systems or 1.544 Mbit/s for T1 systems. The maximum possible capacity is given by genEquipRadioCfgRadioCurrentAvailableCapacity
                             genEquipRadioCfgRadioMultiRadioEnable 1.3.6.1.4.1.2281.10.7.2.1.12 enabledisable read-write
this parameter enables/disables the multi-radio feature for this radio. Notice that for the feature to work it must be configured in two adjacent radios (odd and even slots)
                             genEquipRadioCfgRadioMultiRadioBlockLocalTraffic 1.3.6.1.4.1.2281.10.7.2.1.13 integer read-write
this parameter allows stopping distribution of data to different radios in Multi-Radio mode for debugging purposes Enumeration: 'block-this-radio': 1, 'dont-block': 0.
                             genEquipRadioCfgRadioMultiRadioBlockMateTraffic 1.3.6.1.4.1.2281.10.7.2.1.14 integer read-write
this parameter allows stopping distribution of data to the radio in the mate IDU in Multi-Radio mode for debugging purposes Enumeration: 'block-this-radio': 1, 'dont-block': 0.
                             genEquipRadioCfgRadioCurrentAvailableCapacity 1.3.6.1.4.1.2281.10.7.2.1.15 integer read-only
This parameter indicates the maximum possible capacity available for Ethernet. This sets a top limit for amount of high-priority Ethernet bandwidth
                             genEquipRadioCfgRadioMultiRadioExcessiveBERAdmin 1.3.6.1.4.1.2281.10.7.2.1.16 enabledisable read-write
This parameter configures whether in Multi-Radio mode data stops being distributed to the radio in case of an excessive BER condition
                             genEquipRadioCfgRadioMultiRadioSignalDegradeAdmin 1.3.6.1.4.1.2281.10.7.2.1.17 enabledisable read-write
This parameter configures whether in Multi-Radio mode data stops being distributed to the radio in case of a signal degraded condition
                             genEquipRadioCfgEnAlarmGenOnRslDegrade 1.3.6.1.4.1.2281.10.7.2.1.18 enabledisable read-write
TEnable/Disable alarm and trapgeneration on RSL degradationbelow user defined threshold.If enabled, trap and alarm willbe generated when current RSLlevel degrades below userdefined threshold for 5subsequent seconds. Alarm willbe cleared after RSL level staysabove the threshold for at leastanother 5 seconds. Thresholdis calculated as a nominal RSLlevel minus the degradationmargin.
                             genEquipRadioCfgAlarmGenRslNominalLevel 1.3.6.1.4.1.2281.10.7.2.1.19 integer read-write
RSL nominal level [in dBm] foralarm and event generation.
                             genEquipRadioCfgAlarmGenRslDegradationMargin 1.3.6.1.4.1.2281.10.7.2.1.20 integer read-write
RSL degradation margin [in dB]for alarm and eventgeneration. The margin isrelative to the nominal RSLlevel
                             genEquipRadioCfgLinkShutDownOnRadioFailure 1.3.6.1.4.1.2281.10.7.2.1.21 enabledisable read-write
This parameter enables shutting down the link and initiating automatic state propagation upon a failure in each one of the radios. Radio failure condition is determined by user configurations and can be one of the following: Radio LOF, Link ID mismatch, Radio excessive BER, Radio signal degrade, Link ID mismatch.
                             genEquipRadioCfgLoopbackTimeout 1.3.6.1.4.1.2281.10.7.2.1.22 integer read-write
The timeout in minutes for automatic termination of the loopback. The value '0' refers to 'no timeout'.
                             genEquipRadioCfgAbcMode 1.3.6.1.4.1.2281.10.7.2.1.23 integer read-write
TThe radio mode (multi direction or multi carrier). Enumeration: 'multi-directional': 3, 'multi-carrier-abc': 2.
                     genEquipRemoteRadio 1.3.6.1.4.1.2281.10.7.3
                         genEquipRemoteRadioTable 1.3.6.1.4.1.2281.10.7.3.1 no-access
Remote radio table.
                             genEquipRemoteRadioEntry 1.3.6.1.4.1.2281.10.7.3.1.1 no-access
Remote radio table.
                                 genEquipRemoteRadioRadioId 1.3.6.1.4.1.2281.10.7.3.1.1.1 radioid read-only
This value is the radio ID that serves as this table Index
                                 genEquipRemoteRadioRemoteCommunication 1.3.6.1.4.1.2281.10.7.3.1.1.2 downup read-only
The operational status of the remote radio.
                                 genEquipRemoteRadioRemoteIPAddr 1.3.6.1.4.1.2281.10.7.3.1.1.3 ipaddress read-write
The remote Ip address.
                                 genEquipRemoteRadioRemoteRxLevel 1.3.6.1.4.1.2281.10.7.3.1.1.4 integer read-only
The Rx level of the remote radio (in dBm)
                                 genEquipRemoteRadioRemoteForceMaxTxLevel 1.3.6.1.4.1.2281.10.7.3.1.1.5 integer read-write
Command that forces the remote radio maximum Tx level (in dBm)
                                 genEquipRemoteRadioRemoteTxFreq 1.3.6.1.4.1.2281.10.7.3.1.1.6 integer read-write
The remote radio Tx frequancy (in MHz).
                                 genEquipRemoteRadioRemoteRxFreq 1.3.6.1.4.1.2281.10.7.3.1.1.7 integer read-write
The remote radio Rx frequancy (in MHz).
                                 genEquipRemoteRadioRemoteATPCReferenceRxLevel 1.3.6.1.4.1.2281.10.7.3.1.1.8 integer read-write
The RSL reference level for the ATPC mechanism in the remote radio.
                                 genEquipRemoteRadioRemoteFloatingIPAddr 1.3.6.1.4.1.2281.10.7.3.1.1.9 ipaddress read-write
This value indicates the floating IP address used in the remote shelf if its main units are in 1+1 protection mode.
                                 genEquipRemoteRadioRemoteDefaultGateway 1.3.6.1.4.1.2281.10.7.3.1.1.10 ipaddress read-only
Default gateway of remote NE (Network Element) across this radio link.
                                 genEquipRemoteRadioRemoteMostSevereAlarm 1.3.6.1.4.1.2281.10.7.3.1.1.11 severity read-only
Most severe alarm of remote NE (Network Element) across this radio link.
                                 genEquipRemoteRadioRemoteSubnetMask 1.3.6.1.4.1.2281.10.7.3.1.1.12 ipaddress read-only
Subnet mask of remote NE (Network Element) across this radio link.
                                 genEquipRemoteRadioRemoteSlotID 1.3.6.1.4.1.2281.10.7.3.1.1.13 integer read-only
The remote radio slot number.
                                 genEquipRemoteRadioRemoteForceTxMute 1.3.6.1.4.1.2281.10.7.3.1.1.14 offon read-write
Force the mute state of the remote unit radio interface.
                                 genEquipRemoteRadioRemoteLinkId 1.3.6.1.4.1.2281.10.7.3.1.1.15 integer read-write
The Link Id of the remote unit radio interface.
                                 genEquipRemoteRadioRemoteATPCoverrideState 1.3.6.1.4.1.2281.10.7.3.1.1.16 noyes read-only
Remote Radio ATPC Override Timer expire state.
                                 genEquipRemoteRadioRemoteATPCoverrideStateCancel 1.3.6.1.4.1.2281.10.7.3.1.1.17 noyes read-write
his coomand cancel remote ATPC override state.
                                 genEquipRemoteRadioRemoteDataLoopBackAdmin 1.3.6.1.4.1.2281.10.7.3.1.1.18 enabledisable read-write
Remote unit administrator state of data loopback.
                                 genEquipRemoteRadioRemoteDataLoopBackDuration 1.3.6.1.4.1.2281.10.7.3.1.1.19 integer read-write
Remote Data LoopBack Duration at remote unit[Minutes], zero for infinite loop back.
                                 genEquipRemoteRadioRemoteDataLoopBackSwitchAddress 1.3.6.1.4.1.2281.10.7.3.1.1.20 enabledisable read-write
Remote Unit switch MAC DA.
                                 genEquipRemoteRadioRemoteGreenReferenceRxLevel 1.3.6.1.4.1.2281.10.7.3.1.1.21 integer read-only
Remote Radio Green RSL reference level[dBm].
                                 genEquipRemoteRadioRemoteMNGvlan 1.3.6.1.4.1.2281.10.7.3.1.1.22 integer read-write
Remote Management Vlan.
                                 genEquipRemoteRadioRemoteReset 1.3.6.1.4.1.2281.10.7.3.1.1.23 falsetrue read-write
Remote reset of unit.
                                 genEquipRemoteRadioRemoteGreenModeAdmin 1.3.6.1.4.1.2281.10.7.3.1.1.24 enabledisable read-write
Remote Unit Tx Green Mode Admin.
                                 genEquipRemoteRadioRemoteWebProtocol 1.3.6.1.4.1.2281.10.7.3.1.1.25 communicationchannel read-write
Remote web protocol.
                                 genEquipRemoteRadioRemoteIPv6Addr 1.3.6.1.4.1.2281.10.7.3.1.1.26 octet string read-write
Remote IPv6 Address.
                                 genEquipRemoteRadioRemotePrefixLength 1.3.6.1.4.1.2281.10.7.3.1.1.27 integer read-write
Remote IPv6 Subnet-Mask.
                                 genEquipRemoteRadioRemoteDefaultGatewayIpv6 1.3.6.1.4.1.2281.10.7.3.1.1.28 octet string read-write
Remote IPv6 Default Gateway.
                                 genEquipRemoteRadioRemoteResetSlot 1.3.6.1.4.1.2281.10.7.3.1.1.29 falsetrue read-write
Remote Unit Reset Slot.
                     genEquipRadioMRMC 1.3.6.1.4.1.2281.10.7.4
                         genEquipRadioMRMCTable 1.3.6.1.4.1.2281.10.7.4.1 no-access
MRMC stauts table (Multi rate multi constellation)
                             genEquipRadioMRMCEntry 1.3.6.1.4.1.2281.10.7.4.1.1 no-access
MRMC status table (Multi rate multi constellation)
                                 genEquipRadioMRMCRadioId 1.3.6.1.4.1.2281.10.7.4.1.1.1 radioid read-only
This value is the radio ID that serves as this table Index
                                 genEquipRadioMRMCSelectedScriptIndex 1.3.6.1.4.1.2281.10.7.4.1.1.2 integer read-write
The index of the MRMC script. The description of the script located in the genEquipRadioMRMCScriptTable.
                                 genEquipRadioMRMCOccupidBandwidth 1.3.6.1.4.1.2281.10.7.4.1.1.3 integer read-only
The Occupid Bandwidth (in KHz).
                                 genEquipRadioMRMCOperMode 1.3.6.1.4.1.2281.10.7.4.1.1.4 integer read-only
The Mode of the MRMC script. Enumeration: 'regular-mode': 0, 'acm-adaptive-mode': 2, 'acm-fixed-mode': 1.
                                 genEquipRadioMRMCCurrTxProfile 1.3.6.1.4.1.2281.10.7.4.1.1.5 mrmcprofile read-only
The Tx profile number.
                                 genEquipRadioMRMCCurrTxQAM 1.3.6.1.4.1.2281.10.7.4.1.1.6 integer read-only
The current Tx QAM (modulation).
                                 genEquipRadioMRMCCurrTxBitrate 1.3.6.1.4.1.2281.10.7.4.1.1.7 mrmcbitrate read-only
The current Tx bit rate (in Kbps)
                                 genEquipRadioMRMCCurrTxVc 1.3.6.1.4.1.2281.10.7.4.1.1.8 integer read-only
The current number of Tx TDM channels.
                                 genEquipRadioMRMCCurrRxProfile 1.3.6.1.4.1.2281.10.7.4.1.1.9 mrmcprofile read-only
The current Rx profile number
                                 genEquipRadioMRMCCurrRxQAM 1.3.6.1.4.1.2281.10.7.4.1.1.10 integer read-only
The current Rx QAM (modulation).
                                 genEquipRadioMRMCCurrRxBitrate 1.3.6.1.4.1.2281.10.7.4.1.1.11 mrmcbitrate read-only
The current total Rx bit rate (in Kbps)
                                 genEquipRadioMRMCCurrRxVc 1.3.6.1.4.1.2281.10.7.4.1.1.12 integer read-only
The current number of Rx TDM channels.
                                 genEquipRadioMRMCCurrGrade 1.3.6.1.4.1.2281.10.7.4.1.1.13 rfugrade read-only
The grade of the current script.
                                 genEquipRadioMRMCEnAlarmOnAcmProfileDegrade 1.3.6.1.4.1.2281.10.7.4.1.1.14 enabledisable read-write
Enable/Disable event and trapgeneration on ACM profiledegrade. When enabled and ifcurrent radio script supports Adaptive Code Modulation(ACM) event and trap will begenerated upon ACM profiledegradation below userdefinedthreshold. Alarm willbe generated only if the ACMprofile stays below thethreshold for at least 5 subsequent seconds. Alarm willbe cleared after ACM profilereturns to be above thethreshold again.
                                 genEquipRadioMRMCAlarmOnAcmProfileDegradeThreshold 1.3.6.1.4.1.2281.10.7.4.1.1.15 integer read-write
ACM profile threshold foralarm generation
                         genEquipRadioMRMCScriptTable 1.3.6.1.4.1.2281.10.7.4.2 no-access
The MRMC script table.
                             genEquipRadioMRMCScriptEntry 1.3.6.1.4.1.2281.10.7.4.2.1 no-access
The MRMC script table.
                                 genEquipRadioMRMCScriptRadioId 1.3.6.1.4.1.2281.10.7.4.2.1.1 radioid read-only
This value is the radio ID that serves as this table Index
                                 genEquipRadioMRMCScriptIndex 1.3.6.1.4.1.2281.10.7.4.2.1.2 integer read-only
The index of the MRMC scripts.
                                 genEquipRadioMRMCScriptName 1.3.6.1.4.1.2281.10.7.4.2.1.3 displaystring read-only
The MRMC script name.
                                 genEquipRadioMRMCScriptOperMode 1.3.6.1.4.1.2281.10.7.4.2.1.4 integer read-only
The script operational mode. Enumeration: 'regular-mode': 0, 'acm-adaptive-mode': 2, 'acm-fixed-mode': 1.
                                 genEquipRadioMRMCScriptProfile 1.3.6.1.4.1.2281.10.7.4.2.1.5 mrmcprofile read-only
The profile number of the script
                                 genEquipRadioMRMCScriptProfileBitrate 1.3.6.1.4.1.2281.10.7.4.2.1.6 mrmcbitrate read-only
The Bit rate of the MRMC profile (in Kbps).
                                 genEquipRadioMRMCScriptAdaptivePower 1.3.6.1.4.1.2281.10.7.4.2.1.7 integer read-only
'Adaptive Power' option which is available only when operation mode is ACM-adaptive Enumeration: 'enable-adaptive-power': 0, 'disable-adaptive-power': 1.
                                 genEquipRadioMRMCScriptReference 1.3.6.1.4.1.2281.10.7.4.2.1.8 integer read-only
'Reference Class' option which is available only when operation mode 'ACM-adaptive' AND 'Adaptive Power' are enabled. Enumeration: 'calss-2': 0, 'class-5b': 2, 'class-6a': 3, 'fcc': 4, 'class-4': 1.
                                 genEquipRadioMRMCScriptMinProfile 1.3.6.1.4.1.2281.10.7.4.2.1.9 mrmcprofile read-only
'Minimum Profile' option which is available only when operation mode 'ACM-adaptive' AND 'Adaptive Power' are enabled. It state the minimum profile level for this script.
                         genEquipRadioMRMCFilteredTable 1.3.6.1.4.1.2281.10.7.4.3 no-access
Filtered MRMC scripts table.
                             genEquipRadioMRMCFilteredEntry 1.3.6.1.4.1.2281.10.7.4.3.1 no-access
List of the filtered MRMC scripts.
                                 genEquipRadioMRMCFilteredRadioId 1.3.6.1.4.1.2281.10.7.4.3.1.1 radioid read-only
The index of the radio interface
                                 genEquipRadioMRMCFilteredScriptId 1.3.6.1.4.1.2281.10.7.4.3.1.2 mrmcscriptid read-only
The MRMC filtered script IDs that are available in the specific radio.
                         genEquipRadioMRMCProfileAttrTable 1.3.6.1.4.1.2281.10.7.4.4 no-access
MRMC profile attribute table.
                             genEquipRadioMRMCProfileAttrEntry 1.3.6.1.4.1.2281.10.7.4.4.1 no-access
MRMC script profile's attributes.
                                 genEquipRadioMRMCProfileAttrScriptId 1.3.6.1.4.1.2281.10.7.4.4.1.1 mrmcscriptid read-only
The index of the table
                                 genEquipRadioMRMCProfileAttrTxProfile 1.3.6.1.4.1.2281.10.7.4.4.1.2 mrmcprofile read-only
The profile number of the TX channel.
                                 genEquipRadioMRMCProfileAttrRxProfile 1.3.6.1.4.1.2281.10.7.4.4.1.3 mrmcprofile read-only
The profile number of the RX channel.
                                 genEquipRadioMRMCProfileAttrTxQAM 1.3.6.1.4.1.2281.10.7.4.4.1.4 qamorder read-only
Indicates the QAM level of the TX channel.
                                 genEquipRadioMRMCProfileAttrTxBitRate 1.3.6.1.4.1.2281.10.7.4.4.1.5 mrmcbitrate read-only
Indicates the TX bit-rate of the profile.
                                 genEquipRadioMRMCProfileAttrRxQAM 1.3.6.1.4.1.2281.10.7.4.4.1.6 qamorder read-only
Indicates the QAM level of the RX channel.
                                 genEquipRadioMRMCProfileAttrRxBitRate 1.3.6.1.4.1.2281.10.7.4.4.1.7 mrmcbitrate read-only
RX bit-rate of the profile.
                         genEquipRadioMRMCScriptAttrTable 1.3.6.1.4.1.2281.10.7.4.5 no-access
MRMC script attribute table.
                             genEquipRadioMRMCScriptAttrEntry 1.3.6.1.4.1.2281.10.7.4.5.1 no-access
MRMC script attributes.
                                 genEquipRadioMRMCScriptAttrScriptId 1.3.6.1.4.1.2281.10.7.4.5.1.1 mrmcscriptid read-only
The ID of the MRMC script.
                                 genEquipRadioMRMCScriptAttrScriptName 1.3.6.1.4.1.2281.10.7.4.5.1.2 displaystring read-only
The name that identifies the script.
                                 genEquipRadioMRMCScriptAttrSupportACM 1.3.6.1.4.1.2281.10.7.4.5.1.3 noyes read-only
Indicates if the MRMC script supports ACM (Adaptive Coding Modulation) functionality
                                 genEquipRadioMRMCScriptAttrStandard 1.3.6.1.4.1.2281.10.7.4.5.1.4 integer read-only
The standard that the MRMC script is designed to comply with. Enumeration: 'etsi-fcc': 3, 'unknown': 0, 'etsi': 1, 'fcc': 2.
                                 genEquipRadioMRMCScriptAttrMultiCarrier 1.3.6.1.4.1.2281.10.7.4.5.1.5 integer read-only
Indicates whether the MRMC script support a single carrier or any kind of multi carrier. Enumeration: 'xpic': 1, 'single-carrier': 0, 'mimo': 2.
                                 genEquipRadioMRMCScriptAttrAdjChannel 1.3.6.1.4.1.2281.10.7.4.5.1.6 noyes read-only
Indicates whether the MRMC script supports adjacent channel
                                 genEquipRadioMRMCScriptAttrModScheme 1.3.6.1.4.1.2281.10.7.4.5.1.7 integer read-only
Indicates whether the MRMC script supports fixed or adaptive (ACM) modulation scheme. Enumeration: 'manual': 6, 'adaptive': 4, 'regular': 2, 'fixed-adaptive': 5, 'fixed': 3.
                                 genEquipRadioMRMCScriptAttrSymmetry 1.3.6.1.4.1.2281.10.7.4.5.1.8 integer read-only
Indicates whether the MRMC script is designed to normal (symmetrical) BW or an Asymmetrical BW. Enumeration: 'asymmetry': 1, 'normal': 0.
                                 genEquipRadioMRMCScriptAttrLatency 1.3.6.1.4.1.2281.10.7.4.5.1.9 integer read-only
The Latency level of the MRMC Script. Enumeration: 'low': 1, 'normal': 0.
                                 genEquipRadioMRMCScriptAttrTxBW 1.3.6.1.4.1.2281.10.7.4.5.1.10 integer read-only
The TX channel bandwidth (channel spacing) of the MRMC script.
                                 genEquipRadioMRMCScriptAttrRxBW 1.3.6.1.4.1.2281.10.7.4.5.1.11 integer read-only
The RX channel bandwidth (channel spacing) of the MRMC script.
                                 genEquipRadioMRMCScriptAttrTxOccupiedBW 1.3.6.1.4.1.2281.10.7.4.5.1.12 integer read-only
The TX channel occupied bandwidth of the MRMC script.
                                 genEquipRadioMRMCScriptAttrRxOccupiedBW 1.3.6.1.4.1.2281.10.7.4.5.1.13 integer read-only
The RX channel occupied bandwidth of the MRMC script.
                                 genEquipRadioMRMCScriptAttrLinkGrade 1.3.6.1.4.1.2281.10.7.4.5.1.14 rfugrade read-only
The link grade level that the MRMC script is designed to cope with.
                                 genEquipRadioMRMCScriptAttrDiffGrade 1.3.6.1.4.1.2281.10.7.4.5.1.15 rfugrade read-only
The Differential grade level that the MRMC script is designed to cope with.
                                 genEquipRadioMRMCScriptAttrChannelBW 1.3.6.1.4.1.2281.10.7.4.5.1.16 integer read-only
The channel bandwidth (channel spacing) the MRMC script is designed to.
                                 genEquipRadioMRMCScriptAttrTxMaxProfile 1.3.6.1.4.1.2281.10.7.4.5.1.17 mrmcprofile read-only
The maximum available TX profile of the MRMC script.
                                 genEquipRadioMRMCScriptAttrRxMaxProfile 1.3.6.1.4.1.2281.10.7.4.5.1.18 mrmcprofile read-only
The maximum available RX profile of the MRMC script.
                         genEquipRadioMRMCConfigTable 1.3.6.1.4.1.2281.10.7.4.6 no-access
MRMC script configuration.
                             genEquipRadioMRMCConfigEntry 1.3.6.1.4.1.2281.10.7.4.6.1 no-access
The configured parameters of the MRMC script.
                                 genEquipRadioMRMCConfigRadioId 1.3.6.1.4.1.2281.10.7.4.6.1.1 radioid read-only
The index of the MRMC Configuration Table.
                                 genEquipRadioMRMCConfigActiveScriptId 1.3.6.1.4.1.2281.10.7.4.6.1.2 mrmcscriptid read-write
The script ID of required MRMC script.
                                 genEquipRadioMRMCConfigStandbyScriptId 1.3.6.1.4.1.2281.10.7.4.6.1.3 mrmcscriptid read-write
The script ID which is in standby.
                                 genEquipRadioMRMCConfigOperMode 1.3.6.1.4.1.2281.10.7.4.6.1.4 integer read-write
The operational mode of the MRMC script, whether it is fixed or adaptive modulation functionality. Enumeration: 'adaptive': 3, 'fixed': 2, 'manual': 4.
                                 genEquipRadioMRMCConfigMaxProfile 1.3.6.1.4.1.2281.10.7.4.6.1.5 mrmcprofile read-write
The maximum profile which is required for the MRMC script
                                 genEquipRadioMRMCConfigMinProfile 1.3.6.1.4.1.2281.10.7.4.6.1.6 mrmcprofile read-write
The minimum profile which is required for the MRMC script
                                 genEquipRadioMRMCConfigAdaptivePowerAdmin 1.3.6.1.4.1.2281.10.7.4.6.1.7 enabledisable read-write
Enable or disable the adaptive power functionality during ACM operation.
                                 genEquipRadioMRMCConfigAdaptivePowerRefClass 1.3.6.1.4.1.2281.10.7.4.6.1.8 integer read-write
Determines the efficiency class for the adaptive power functionality in ACM operation. Enumeration: 'class-7a': 5, 'class-6a': 3, 'class-5b': 2, 'class-7b': 6, 'fcc': 4, 'class-2': 0, 'class-4': 1.
                     genEquipRadioComp 1.3.6.1.4.1.2281.10.7.5
                         genEquipRadioCompCfgTable 1.3.6.1.4.1.2281.10.7.5.1 no-access
Radio Compression table
                             genEquipRadioCompCfgEntry 1.3.6.1.4.1.2281.10.7.5.1.1 no-access
Radio Compression table
                                 genEquipRadioCompMode 1.3.6.1.4.1.2281.10.7.5.1.1.1 integer read-write
Setting Ethernet packet header & payload compression mode. In Enhanced mode packet header can be compressed up to L4 and data compression can be activated. Legacy mode is back compatible to earlier software and hardware releases. Enumeration: 'legacy': 0, 'enhanced': 1.
                                 genEquipRadioEnhHeaderCompAdmin 1.3.6.1.4.1.2281.10.7.5.1.1.2 allowednotallowed read-write
Enable/Disable Enhanced Header compression.
                                 genEquipRadioEnhDataCompAdmin 1.3.6.1.4.1.2281.10.7.5.1.1.3 enabledisable read-write
Enable/Disable Enhanced Data compression.
                                 genEquipRadioEnhHeaderCompMode 1.3.6.1.4.1.2281.10.7.5.1.1.4 integer read-write
Setting Enhanced Header Compression depth. Enumeration: 'l4': 2, 'l2': 0, 'l3': 1.
                         genEquipRadioCompStatusTable 1.3.6.1.4.1.2281.10.7.5.2 no-access
Radio Compression status table.
                             genEquipRadioCompStatusEntry 1.3.6.1.4.1.2281.10.7.5.2.1 no-access
Radio Compression status table.
                                 genEquipRadioCompOperationalState 1.3.6.1.4.1.2281.10.7.5.2.1.1 integer read-only
Current compression mode operational status. Enumeration: 'undefined': 5, 'enhanced-HC-DC-active': 4, 'enhanced-DC-active-HC-bypass': 3, 'enhanced-HC-DC-bypass': 1, 'legacy': 0, 'enhanced-HC-active-DC-bypass': 2.
                         genEquipRadioCompExclRulesTable 1.3.6.1.4.1.2281.10.7.5.3 no-access
Enhanced Header Compression excluding rules table.
                             genEquipRadioCompExclRulesEntry 1.3.6.1.4.1.2281.10.7.5.3.1 no-access
Enhanced Header Compression excluding rules table.
                                 genEquipRadioCompExclRuleId 1.3.6.1.4.1.2281.10.7.5.3.1.1 integer read-only
Excluding rule number index.
                                 genEquipRadioCompExclRuleType 1.3.6.1.4.1.2281.10.7.5.3.1.2 integer read-write
Add excluding rule for enhanced header compression. Excluding rule must have a number (rule-id), text description (rule-name) and excluding rule type whichcan be one of the following: VLAN Id or MAC destination address or MAC source address or Ethernet ethertype or user defined flow type. Enumeration: 'flow-Id': 0, 'none': 5, 'ethertype': 4, 'vlan': 1, 'mac-SA': 3, 'mac-DA': 2.
                                 genEquipRadioCompExclRuleName 1.3.6.1.4.1.2281.10.7.5.3.1.3 displaystring read-write
Excluding rule name. User specified.
                                 genEquipRadioCompExclRuleValue 1.3.6.1.4.1.2281.10.7.5.3.1.4 octet string read-write
Excluding rule value. For example: MAC address or Ethertype.
                                 genEquipRadioCompExclRuleRowStatus 1.3.6.1.4.1.2281.10.7.5.3.1.30 rowstatus read-write
Row status for this table.
                         genEquipRadioCompNG 1.3.6.1.4.1.2281.10.7.5.4
                             genEquipRadioCompNGCfgTable 1.3.6.1.4.1.2281.10.7.5.4.1 no-access
Radio Ethernet and compression config table
                                 genEquipRadioCompNGCfgEntry 1.3.6.1.4.1.2281.10.7.5.4.1.1 no-access
Radio Ethernet and compression config table entry
                                     genEquipRadioCompNGCfgifIndex 1.3.6.1.4.1.2281.10.7.5.4.1.1.1 integer read-write
Interface Index.
                                     genEquipRadioHeaderCompNGCfgClearStats 1.3.6.1.4.1.2281.10.7.5.4.1.1.2 noyes read-write
Clear counters on the radio port. This includes: compression counters, PTP optimized transport and cut-through counters.
                                     genEquipRadioHeaderCompNGCfgUserFlowType 1.3.6.1.4.1.2281.10.7.5.4.1.1.3 integer read-write
User configured flow type for enhanced HC. This flow type is used for statistics and performance evaluation of the enhanced HC.
                                     genEquipRadioHeaderCompNGCfgMode 1.3.6.1.4.1.2281.10.7.5.4.1.1.4 hcmodetype read-write
Legacy mode is compatible for old platforms. Disabled mode disables compression. Other modes specify compression depth.
                                     genEquipRadioCutThroughNGCfgMode 1.3.6.1.4.1.2281.10.7.5.4.1.1.5 noyes read-write
Enable/Disable cut-through.
                             genEquipRadioCompNGExclRulesTable 1.3.6.1.4.1.2281.10.7.5.4.2 no-access
Enhanced HC excluding rules table
                                 genEquipRadioCompNGExclRulesEntry 1.3.6.1.4.1.2281.10.7.5.4.2.1 no-access
Enhanced HC excluding rules table entry
                                     genEquipRadioCompNGExclRulesifIndex 1.3.6.1.4.1.2281.10.7.5.4.2.1.1 integer read-only
Interface Index.
                                     genEquipRadioCompNGExclRuleId 1.3.6.1.4.1.2281.10.7.5.4.2.1.2 integer read-only
Excluding rule number.
                                     genEquipRadioCompNGExclRuleName 1.3.6.1.4.1.2281.10.7.5.4.2.1.3 displaystring read-only
Excluding rule name.
                                     genEquipRadioCompNGExclRuleType 1.3.6.1.4.1.2281.10.7.5.4.2.1.4 enhancedhcexclruletype read-only
Excluding rule type. Possible options are: DA MAC, SA MAC, VLAN(4 bytes), Ethertype or Flow type.
                                     genEquipRadioCompNGExclRuleValue 1.3.6.1.4.1.2281.10.7.5.4.2.1.5 octet string read-only
Excluding rule value. The value may be MAC address, VLAN(4 bytes), Ethertype(2 bytes) or Flow type(1 byte).
                             genEquipRadioCutThroughNGCountersTable 1.3.6.1.4.1.2281.10.7.5.4.3 no-access
Port counters table
                                 genEquipRadioCutThroughNGCountersEntry 1.3.6.1.4.1.2281.10.7.5.4.3.1 no-access
Port counters table entry
                                     genEquipRadioCutThroughNGCountersifIndex 1.3.6.1.4.1.2281.10.7.5.4.3.1.1 integer read-only
Interface Index.
                                     genEquipRadioCutThroughNGCountersRxFrames 1.3.6.1.4.1.2281.10.7.5.4.3.1.2 counter64 read-only
Counter of good cut-through bytes received.
                                     genEquipRadioCutThroughNGCountersRxBytes 1.3.6.1.4.1.2281.10.7.5.4.3.1.3 counter64 read-only
Counter of good cut-through bytes received.
                                     genEquipRadioCutThroughNGCountersTxFrames 1.3.6.1.4.1.2281.10.7.5.4.3.1.4 counter64 read-only
Counter of cut-through frames transmitted.
                                     genEquipRadioCutThroughNGCountersTxBytes 1.3.6.1.4.1.2281.10.7.5.4.3.1.5 counter64 read-only
Counter of cut-through bytes transmitted.
                                     genEquipRadioCutThroughNGCountersTotalRxFrames 1.3.6.1.4.1.2281.10.7.5.4.3.1.6 counter64 read-only
Counter of total good frames received on the port.
                                     genEquipRadioCutThroughNGCountersTotalRxBytes 1.3.6.1.4.1.2281.10.7.5.4.3.1.7 counter64 read-only
Counter of total good bytes received on the port.
                                     genEquipRadioCutThroughNGCountersTotalTxBytesOut 1.3.6.1.4.1.2281.10.7.5.4.3.1.8 counter64 read-only
Counter of total transmitted bytes.
                                     genEquipRadioCutThroughNGCountersTotalTxFrames 1.3.6.1.4.1.2281.10.7.5.4.3.1.9 counter64 read-only
Counter of total transmitted frames.
                                     genEquipRadioCutThroughNGCountersTotalTxIdleBytes 1.3.6.1.4.1.2281.10.7.5.4.3.1.10 counter64 read-only
Counter of total transmitted idle bytes.
                                     genEquipRadioCutThroughNGCountersTotalTxBytesIn 1.3.6.1.4.1.2281.10.7.5.4.3.1.11 counter64 read-only
Counter of total transmitted bytes.
                             genEquipRadioCompNGStatusTable 1.3.6.1.4.1.2281.10.7.5.4.4 no-access
Radio Ethernet and compression status table
                                 genEquipRadioCompNGStatusEntry 1.3.6.1.4.1.2281.10.7.5.4.4.1 no-access
Radio Ethernet and compression status table entry
                                     genEquipRadioCompNGStatusifindex 1.3.6.1.4.1.2281.10.7.5.4.4.1.1 integer read-only
Interface location.
                                     genEquipRadioCompNGStatusOperationalState 1.3.6.1.4.1.2281.10.7.5.4.4.1.2 hcmodetype read-only
Header Compression operational state.
                                     genEquipRadioCompNGStatusType 1.3.6.1.4.1.2281.10.7.5.4.4.1.3 hctype read-only
Header Compression type.
                             genEquipRadioCompNGCountersTable 1.3.6.1.4.1.2281.10.7.5.4.7 no-access
Enhanced HC counters table
                                 genEquipRadioCompNGCountersEntry 1.3.6.1.4.1.2281.10.7.5.4.7.1 no-access
Enhanced HC counters table entry
                                     genEquipRadioCompNGCountersifIndex 1.3.6.1.4.1.2281.10.7.5.4.7.1.1 integer read-only
Interface location.
                                     genEquipRadioCompNGCountersHCInBytes 1.3.6.1.4.1.2281.10.7.5.4.7.1.2 counter64 read-only
Counter of bytes on the TX side before enhanced header compression.
                                     genEquipRadioCompNGCountersHCOutBytes 1.3.6.1.4.1.2281.10.7.5.4.7.1.3 counter64 read-only
Counter of bytes on the TX side compressed by enhanced header compression.
                                     genEquipRadioCompNGCountersHCCompFrm 1.3.6.1.4.1.2281.10.7.5.4.7.1.4 counter64 read-only
Counter of frames on the TX side compressed by enhanced header compression.
                                     genEquipRadioCompNGCountersHCFrmUncmpExclRule 1.3.6.1.4.1.2281.10.7.5.4.7.1.5 counter64 read-only
Counter of frames on the TX side not compressed by enhanced header compression due to excluding rules.
                                     genEquipRadioCompNGCountersHCFrmUcompInternal 1.3.6.1.4.1.2281.10.7.5.4.7.1.6 counter64 read-only
Counter of frames on the TX side not compressed by enhanced header compression due to other resons.
                                     genEquipRadioCompNGCountersHCLearningFrm 1.3.6.1.4.1.2281.10.7.5.4.7.1.7 counter64 read-only
Counter of learning frames transmitted by enhanced header compression.
                                     genEquipRadioCompNGCountersHCUserFlowTypeActiveFlows 1.3.6.1.4.1.2281.10.7.5.4.7.1.8 counter64 read-only
Number of enhanced HC active flows occupied by user selected flow type.
                                     genEquipRadioCompNGCountersHCTotalActiveFlows 1.3.6.1.4.1.2281.10.7.5.4.7.1.9 counter64 read-only
Number of enhanced HC active flows on the TX side.
                     genEquipRadioPtpTransport 1.3.6.1.4.1.2281.10.7.6
                         genEquipRadioPtpTransportCfgTable 1.3.6.1.4.1.2281.10.7.6.1 no-access
PTP optimized transport channel configuration table.
                             genEquipRadioPtpTransportCfgEntry 1.3.6.1.4.1.2281.10.7.6.1.1 no-access
PTP optimized transport channel configuration table.
                                 genEquipRadioPtpTransportChannelAdmin 1.3.6.1.4.1.2281.10.7.6.1.1.1 enabledisable read-write
PTP optimized transport admin.
                                 genEquipRadioPtpTransportChannelMode 1.3.6.1.4.1.2281.10.7.6.1.1.2 integer read-write
PTP optimized transport operational mode. Enumeration: 'ieee-1588': 1, 'h-cos': 0.
                         genEquipRadioPtpTransportCountersTable 1.3.6.1.4.1.2281.10.7.6.2 no-access
PTP optimized transport channel counters table.
                             genEquipRadioPtpTransportCountersEntry 1.3.6.1.4.1.2281.10.7.6.2.1 no-access
PTP optimized transport channel counters table.
                                 genEquipRadioPtpTransportTxFrames 1.3.6.1.4.1.2281.10.7.6.2.1.1 integer read-only
PTP optimized transport TX frames.
                                 genEquipRadioPtpTransportTxDroppedFrames 1.3.6.1.4.1.2281.10.7.6.2.1.2 integer read-only
PTP optimized transport TX dropped frames.
                                 genEquipRadioPtpTransportTxBytes 1.3.6.1.4.1.2281.10.7.6.2.1.3 integer read-only
PTP optimized transport TX bytes.
                                 genEquipRadioPtpTransportTxDroppedBytes 1.3.6.1.4.1.2281.10.7.6.2.1.4 integer read-only
PTP optimized transport TX dropped bytes.
                                 genEquipRadioPtpTransportRxFrames 1.3.6.1.4.1.2281.10.7.6.2.1.5 integer read-only
PTP optimized transport RX frames.
                                 genEquipRadioPtpTransportRxBytes 1.3.6.1.4.1.2281.10.7.6.2.1.6 integer read-only
PTP optimized transport RX bytes.
                     genEquipRadioCutThrough 1.3.6.1.4.1.2281.10.7.7
                         genEquipRadioCutThroughCfgTable 1.3.6.1.4.1.2281.10.7.7.1 no-access
Cut through configuration table.
                             genEquipRadioCutThroughCfgEntry 1.3.6.1.4.1.2281.10.7.7.1.1 no-access
Cut through configuration table.
                                 genEquipRadioCutThroughChannelAdmin 1.3.6.1.4.1.2281.10.7.7.1.1.1 enabledisable read-write
Enable/Disable cut through mode.
                         genEquipRadioCutThroughCountersTable 1.3.6.1.4.1.2281.10.7.7.2 no-access
Cut through mode counters table.
                             genEquipRadioCutThroughCountersEntry 1.3.6.1.4.1.2281.10.7.7.2.1 no-access
Cut through mode counters table.
                                 genEquipRadioCutThroughTxFrames 1.3.6.1.4.1.2281.10.7.7.2.1.1 integer read-only
Cut through TX frames.
                                 genEquipRadioCutThroughTxBytes 1.3.6.1.4.1.2281.10.7.7.2.1.2 integer read-only
Cut through TX bytes.
                                 genEquipRadioCutThroughRxFrames 1.3.6.1.4.1.2281.10.7.7.2.1.3 integer read-only
Cut through RX frames.
                                 genEquipRadioCutThroughRxBytes 1.3.6.1.4.1.2281.10.7.7.2.1.4 integer read-only
Cut through RX bytes.
                     genEquipRadioGroups 1.3.6.1.4.1.2281.10.7.8
                         genEquipRadioGroupsProtection 1.3.6.1.4.1.2281.10.7.8.1
                             genEquipRadioGroupsProtectionAttrTable 1.3.6.1.4.1.2281.10.7.8.1.1 no-access
This table contains the attributes of the radio protection groups.
                                 genEquipRadioGroupsProtectionAttrEntry 1.3.6.1.4.1.2281.10.7.8.1.1.1 no-access
This table entry contains the attributes of the radio protection groups.
                                     genEquipRadioGroupsProtectionAttrGroupIfIndex 1.3.6.1.4.1.2281.10.7.8.1.1.1.1 integer read-only
The location of the group
                                     genEquipRadioGroupsProtectionAttrGroupId 1.3.6.1.4.1.2281.10.7.8.1.1.1.2 integer read-write
The Id of the radio protection group.
                                     genEquipRadioGroupsProtectionAttrCommand 1.3.6.1.4.1.2281.10.7.8.1.1.1.3 radioprotectioncmd read-write
Radio protection user commands for maintenance purposes: force-switch, lockout and manual-switch.
                                     genEquipRadioGroupsProtectionAttrCopyToMate 1.3.6.1.4.1.2281.10.7.8.1.1.1.4 offon read-write
Copy to mate command that copies the configuration from one radio to another in order to achieve configuration alignment.
                                     genEquipRadioGroupsProtectionAttrCopyToMateSourceIfIndex 1.3.6.1.4.1.2281.10.7.8.1.1.1.5 integer read-write
The radio location which is required to be the source of configuration for copy-to-mate command.
                                     genEquipRadioGroupsProtectionAttrRevertiveAdmin 1.3.6.1.4.1.2281.10.7.8.1.1.1.6 enabledisable read-write
Enable or disable revertive mode of radio protection.
                                     genEquipRadioGroupsProtectionAttrRevertivePrimaryIfIndex 1.3.6.1.4.1.2281.10.7.8.1.1.1.7 integer read-write
The radio which the system is required to revert to.
                             genEquipRadioGroupsProtectionMembersTable 1.3.6.1.4.1.2281.10.7.8.1.2 no-access
This table contains the radio protection groups members.
                                 genEquipRadioGroupsProtectionMembersEntry 1.3.6.1.4.1.2281.10.7.8.1.2.1 no-access
This table entry contains the radio protection groups members.
                                     genEquipRadioGroupsProtectionMembersIfIndexGroup 1.3.6.1.4.1.2281.10.7.8.1.2.1.1 integer read-only
The location of the radio protection group
                                     genEquipRadioGroupsProtectionMembersGroupId 1.3.6.1.4.1.2281.10.7.8.1.2.1.2 integer read-only
The Id of the radio protection group.
                                     genEquipRadioGroupsProtectionMembersMem1IfIndex 1.3.6.1.4.1.2281.10.7.8.1.2.1.3 integer read-write
The radio location of member 1.
                                     genEquipRadioGroupsProtectionMembersMem2IfIndex 1.3.6.1.4.1.2281.10.7.8.1.2.1.4 integer read-write
The radio location of member 2.
                                     genEquipRadioGroupsProtectionMembersRowStatus 1.3.6.1.4.1.2281.10.7.8.1.2.1.30 rowstatus read-write
Row status to allow user add entries dynamically.
                             genEquipRadioGroupsProtectionStatusTable 1.3.6.1.4.1.2281.10.7.8.1.3 no-access
This table contains the status of the radio protection.
                                 genEquipRadioGroupsProtectionStatusEntry 1.3.6.1.4.1.2281.10.7.8.1.3.1 no-access
This table entry contains the status of the radio protection.
                                     genEquipRadioGroupsProtectionStatusGroupIfIndex 1.3.6.1.4.1.2281.10.7.8.1.3.1.1 integer read-only
The location of the group
                                     genEquipRadioGroupsProtectionStatusActiveIfIndex 1.3.6.1.4.1.2281.10.7.8.1.3.1.2 integer read-only
The active radio location
                                     genEquipRadioGroupsProtectionStatusStandbyIfIndex 1.3.6.1.4.1.2281.10.7.8.1.3.1.3 integer read-only
The standby radio location.
                                     genEquipRadioGroupsProtectionStatusLockout 1.3.6.1.4.1.2281.10.7.8.1.3.1.4 noyes read-only
The radio location of member 1.
                             genEquipRadioGroupsProtectionBBSSD 1.3.6.1.4.1.2281.10.7.8.1.10
                                   genEquipRadioGroupsProtectionBBSSDAttrTable 1.3.6.1.4.1.2281.10.7.8.1.10.1 no-access
This table contains the BBS-SD attributes of the radio protection groups.
                                       genEquipRadioGroupsProtectionBBSSDAttrEntry 1.3.6.1.4.1.2281.10.7.8.1.10.1.1 no-access
This table entry contains the BBS-SD attributes of the radio protection groups.
                                           genEquipRadioGroupsProtectionBBSSDAttrGroupIfIndex 1.3.6.1.4.1.2281.10.7.8.1.10.1.1.1 integer read-only
The location of the group
                                           genEquipRadioGroupsProtectionBBSSDAttrRevertive 1.3.6.1.4.1.2281.10.7.8.1.10.1.1.2 enabledisable read-write
Enable or disable revertive mode for BBS-SD Rx switch.
                                           genEquipRadioGroupsProtectionBBSSDAttrClrSwCnt 1.3.6.1.4.1.2281.10.7.8.1.10.1.1.3 offon read-write
Clear BBS-SD Rx switch counter.
                                           genEquipRadioGroupsProtectionBBSSDAttrFWAuto 1.3.6.1.4.1.2281.10.7.8.1.10.1.1.4 enabledisable read-write
Enable or disable automatic Rx switching in BBS-SD.
                                   genEquipRadioGroupsProtectionBBSSDStatusTable 1.3.6.1.4.1.2281.10.7.8.1.10.2 no-access
This table contains the BBS-SD status of the radio protection groups.
                                       genEquipRadioGroupsProtectionBBSSDStatusEntry 1.3.6.1.4.1.2281.10.7.8.1.10.2.1 no-access
This table entry contains the BBS-SD status of the radio protection groups.
                                           genEquipRadioGroupsProtectionBBSSDStatusGroupIfIndex 1.3.6.1.4.1.2281.10.7.8.1.10.2.1.1 integer read-only
The location of the group
                                           genEquipRadioGroupsProtectionBBSSDStatusAbcGroupIfIndex 1.3.6.1.4.1.2281.10.7.8.1.10.2.1.2 integer read-only
The attached MC-ABC group if_index.
                                           genEquipRadioGroupsProtectionBBSSDStatusActiveRxQuality 1.3.6.1.4.1.2281.10.7.8.1.10.2.1.3 integer read-only
The active MC-ABC channel quality.
                                           genEquipRadioGroupsProtectionBBSSDStatusActiveRxRadioIfIndex 1.3.6.1.4.1.2281.10.7.8.1.10.2.1.4 integer read-only
The active rx radio if_index.
                                           genEquipRadioGroupsProtectionBBSSDStatusActiveTxRadioIfIndex 1.3.6.1.4.1.2281.10.7.8.1.10.2.1.5 integer read-only
The active Tx radio if_index.
                                           genEquipRadioGroupsProtectionBBSSDStatusLockout 1.3.6.1.4.1.2281.10.7.8.1.10.2.1.6 noyes read-only
Indicates whether the radio protection is currently in lockout.
                                           genEquipRadioGroupsProtectionBBSSDStatusRxChId 1.3.6.1.4.1.2281.10.7.8.1.10.2.1.7 integer read-only
The attached MC-ABC channel ID.
                                           genEquipRadioGroupsProtectionBBSSDStatusStdbyRxQuality 1.3.6.1.4.1.2281.10.7.8.1.10.2.1.8 integer read-only
The standby MC-ABC channel quality.
                                           genEquipRadioGroupsProtectionBBSSDStatusStdbyRxRadioIfIndex 1.3.6.1.4.1.2281.10.7.8.1.10.2.1.9 integer read-only
The standby rx radio if_index.
                                           genEquipRadioGroupsProtectionBBSSDStatusStandbyTxRadioIfIndex 1.3.6.1.4.1.2281.10.7.8.1.10.2.1.10 integer read-only
The standby Tx radio if_index.
                         genEquipRadioGroupsXpic 1.3.6.1.4.1.2281.10.7.8.2
                             genEquipRadioGroupsXPICAttrTable 1.3.6.1.4.1.2281.10.7.8.2.1 no-access
This table contains the configuration of the radio XPIC groups.
                                 genEquipRadioGroupsXPICAttrEntry 1.3.6.1.4.1.2281.10.7.8.2.1.1 no-access
This table entry contains the configuration of the radio XPIC groups.
                                     genEquipRadioGroupsXPICAttrGroupIfIndex 1.3.6.1.4.1.2281.10.7.8.2.1.1.1 integer read-only
The location of the group.
                                     genEquipRadioGroupsXPICAttrCopyToMateSourceIfIndex 1.3.6.1.4.1.2281.10.7.8.2.1.1.2 integer read-write
The radio location which is required to be the source of configuration for copy-to-mate command.
                                     genEquipRadioGroupsXPICAttrGroupId 1.3.6.1.4.1.2281.10.7.8.2.1.1.3 integer read-write
XPIC group id.
                                     genEquipRadioGroupsXPICAttrXRSMAdmin 1.3.6.1.4.1.2281.10.7.8.2.1.1.4 enabledisable read-write
Administrative state of XPIC recovery state machine.
                                     genEquipRadioGroupsXPICAttrAdmin 1.3.6.1.4.1.2281.10.7.8.2.1.1.5 enabledisable read-write
Administrative state of XPIC.
                                     genEquipRadioGroupsXPICAttrCopyToMate 1.3.6.1.4.1.2281.10.7.8.2.1.1.6 copy2mate read-write
User Command to resolve the mismatch between the two carriers in the XPIC group.
                             genEquipRadioGroupsXPICMembersTable 1.3.6.1.4.1.2281.10.7.8.2.2 no-access
This table contains the radio XPIC groups members.
                                 genEquipRadioGroupsXPICMembersEntry 1.3.6.1.4.1.2281.10.7.8.2.2.1 no-access
This table entry contains the radio XPIC groups members.
                                     genEquipRadioGroupsXPICMembersIfIndexGroup 1.3.6.1.4.1.2281.10.7.8.2.2.1.1 integer read-only
The location of the radio XPIC group.
                                     genEquipRadioGroupsXPICMembersMem1IfIndex 1.3.6.1.4.1.2281.10.7.8.2.2.1.2 integer read-write
The radio location of member 1.
                                     genEquipRadioGroupsXPICMembersMem2IfIndex 1.3.6.1.4.1.2281.10.7.8.2.2.1.3 integer read-write
The radio location of member 2.
                                     genEquipRadioGroupsXPICMembersRowStatus 1.3.6.1.4.1.2281.10.7.8.2.2.1.30 rowstatus read-write
Row status to allow user add entries dynamically.
                             genEquipRadioGroupsXPICStatusTable 1.3.6.1.4.1.2281.10.7.8.2.3 no-access
This table contains the status of the XPIC.
                                 genEquipRadioGroupsXPICStatusEntry 1.3.6.1.4.1.2281.10.7.8.2.3.1 no-access
This table entry contains the status of the XPIC.
                                     genEquipRadioGroupsXPICStatusGroupIfIndex 1.3.6.1.4.1.2281.10.7.8.2.3.1.1 integer read-only
The location of the group
                                     genEquipRadioGroupsXPICStatusState 1.3.6.1.4.1.2281.10.7.8.2.3.1.2 xpicstate read-only
The state of XPIC State Machine
                         genEquipRadioGroupsMR 1.3.6.1.4.1.2281.10.7.8.3
                             genEquipRadioGroupsMRAttrTable 1.3.6.1.4.1.2281.10.7.8.3.1 no-access
MR config table.
                                 genEquipRadioGroupsMRAttrEntry 1.3.6.1.4.1.2281.10.7.8.3.1.1 no-access
MR config table entry.
                                     genEquipRadioGroupsMRAttrGroupIfIndex 1.3.6.1.4.1.2281.10.7.8.3.1.1.1 integer read-only
The location of the group
                                     genEquipRadioGroupsMRAttrGroupId 1.3.6.1.4.1.2281.10.7.8.3.1.1.2 integer read-only
The Id of the radio MR group.
                                     genEquipRadioGroupsMRAttrAdmin 1.3.6.1.4.1.2281.10.7.8.3.1.1.3 enabledisable read-write
MR Admin.
                                     genEquipRadioGroupsMRAttrBlockRadioIfindex 1.3.6.1.4.1.2281.10.7.8.3.1.1.4 integer read-write
Block Radio ifindex.
                                     genEquipRadioGroupsMRAttrBlockRadioAdmin 1.3.6.1.4.1.2281.10.7.8.3.1.1.5 enabledisable read-write
Block Radio Admin.
                                     genEquipRadioGroupsMRAttrCopy2MateIfindex 1.3.6.1.4.1.2281.10.7.8.3.1.1.6 integer read-write
Copy2mate Radio ifindex.
                                     genEquipRadioGroupsMRAttrCopy2MateAdmin 1.3.6.1.4.1.2281.10.7.8.3.1.1.7 enabledisable read-write
Copy2Mate Admin.
                                     genEquipRadioGroupsMRAttrExBerAdmin 1.3.6.1.4.1.2281.10.7.8.3.1.1.8 enabledisable read-write
Excessive BER Admin.
                                     genEquipRadioGroupsMRAttrMinNumRadio 1.3.6.1.4.1.2281.10.7.8.3.1.1.9 integer read-write
Minimal num of radios.
                                     genEquipRadioGroupsMRAttrMinProfileAdmin 1.3.6.1.4.1.2281.10.7.8.3.1.1.10 enabledisable read-write
Min ACM profile admin.
                                     genEquipRadioGroupsMRAttrSigDegardeAdmin 1.3.6.1.4.1.2281.10.7.8.3.1.1.11 enabledisable read-write
Signal Degrade Admin.
                             genEquipRadioGroupsMRMembersTable 1.3.6.1.4.1.2281.10.7.8.3.2 no-access
MR members table.
                                 genEquipRadioGroupsMRMembersEntry 1.3.6.1.4.1.2281.10.7.8.3.2.1 no-access
MR members table entry.
                                     genEquipRadioGroupsMRMembersIfIndexGroup 1.3.6.1.4.1.2281.10.7.8.3.2.1.1 integer read-only
The location of the radio MR group
                                     genEquipRadioGroupsMRMembersMem1IfIndex 1.3.6.1.4.1.2281.10.7.8.3.2.1.2 integer read-write
The radio location of member 1.
                                     genEquipRadioGroupsMRMembersMem2IfIndex 1.3.6.1.4.1.2281.10.7.8.3.2.1.3 integer read-write
The radio location of member 2.
                                     genEquipRadioGroupsMRMembersRowStatus 1.3.6.1.4.1.2281.10.7.8.3.2.1.30 rowstatus read-write
Row status to allow user add entries dynamically.
                             genEquipRadioGroupsMRStatusTable 1.3.6.1.4.1.2281.10.7.8.3.3 no-access
MR Status table.
                                 genEquipRadioGroupsMRStatusEntry 1.3.6.1.4.1.2281.10.7.8.3.3.1 no-access
MR Status table entry.
                                     genEquipRadioGroupsMRStatusGroupIfIndex 1.3.6.1.4.1.2281.10.7.8.3.3.1.1 integer read-only
The location of the group
                                     genEquipRadioGroupsMRStatusOpertionalState 1.3.6.1.4.1.2281.10.7.8.3.3.1.2 integer read-only
Operational State
                                     genEquipRadioGroupsMRStatusRemoteOpertionalState 1.3.6.1.4.1.2281.10.7.8.3.3.1.3 integer read-only
Remote Operational State.
                         genEquipRadioGroupsMIMO 1.3.6.1.4.1.2281.10.7.8.4
                             genEquipRadioGroupsMIMOAttrTable 1.3.6.1.4.1.2281.10.7.8.4.1 no-access
The configuration table of the MIMO groups.
                                 genEquipRadioGroupsMIMOAttrEntry 1.3.6.1.4.1.2281.10.7.8.4.1.1 no-access
The configuration table of the MIMO groups entry.
                                     genEquipRadioGroupsMIMOAttrGroupIfIndex 1.3.6.1.4.1.2281.10.7.8.4.1.1.1 integer read-only
MIMO configuration table index
                                     genEquipRadioGroupsMIMOAttrRole 1.3.6.1.4.1.2281.10.7.8.4.1.1.2 integer read-write
Role can be Master or Slave. Enumeration: 'master': 1, 'not-relevant': 2, 'slave': 0.
                                     genEquipRadioGroupsMIMOAttrAdmin 1.3.6.1.4.1.2281.10.7.8.4.1.1.3 enabledisable read-write
Administrating state of the MIMO group.
                                     genEquipRadioGroupsMIMOAttrResetStateMachine 1.3.6.1.4.1.2281.10.7.8.4.1.1.4 offon read-write
Reset MIMO state machine.
                             genEquipRadioGroupsMIMOMembersTable 1.3.6.1.4.1.2281.10.7.8.4.2 no-access
The description the radio carrier members of the MIMO groups.
                                 genEquipRadioGroupsMIMOMembersEntry 1.3.6.1.4.1.2281.10.7.8.4.2.1 no-access
The description the radio carrier members of the MIMO groups entry.
                                     genEquipRadioGroupsMIMOMembersGroupIfIndex 1.3.6.1.4.1.2281.10.7.8.4.2.1.1 integer read-only
MIMO members table index
                                     genEquipRadioGroupsMIMOMembersGroupType 1.3.6.1.4.1.2281.10.7.8.4.2.1.2 integer read-write
Type of MIMO group: 2x2 or 4x4 etc... Enumeration: 'mimo-2x2': 0, 'base-band-combining-4x4': 3, 'base-band-combining-2x2': 2, 'mimo-4x4': 1.
                                     genEquipRadioGroupsMIMOMembersMem1IfIndex 1.3.6.1.4.1.2281.10.7.8.4.2.1.3 integer read-write
The radio location of member 1.
                                     genEquipRadioGroupsMIMOMembersMem2IfIndex 1.3.6.1.4.1.2281.10.7.8.4.2.1.4 integer read-write
The radio location of member 2.
                                     genEquipRadioGroupsMIMOMembersMem3IfIndex 1.3.6.1.4.1.2281.10.7.8.4.2.1.5 integer read-write
The radio location of member 3.
                                     genEquipRadioGroupsMIMOMembersMem4IfIndex 1.3.6.1.4.1.2281.10.7.8.4.2.1.6 integer read-write
The radio location of member 4.
                                     genEquipRadioGroupsMIMOMembersRowStatus 1.3.6.1.4.1.2281.10.7.8.4.2.1.30 rowstatus read-write
Row status to allow user add entries dynamically.
                             genEquipRadioGroupsMIMOStatusTable 1.3.6.1.4.1.2281.10.7.8.4.3 no-access
The current status table of the MIMO groups.
                                 genEquipRadioGroupsMIMOStatusEntry 1.3.6.1.4.1.2281.10.7.8.4.3.1 no-access
The current status table of the MIMO groups entry.
                                     genEquipRadioGroupsMIMOStatusGroupIfIndex 1.3.6.1.4.1.2281.10.7.8.4.3.1.1 integer read-only
MIMO status table index
                                     genEquipRadioGroupsMIMOStatusState 1.3.6.1.4.1.2281.10.7.8.4.3.1.2 integer read-only
MIMO-State Enumeration: 'slave': 0, 'half-capacity': 5, 'idle': 3, 'disabled': 2, 'init': 1, 'recovery': 4.
                                     genEquipRadioGroupsMIMOStatus1stMMI 1.3.6.1.4.1.2281.10.7.8.4.3.1.3 integer read-only
MIMO interference in dB of the 1st carrier.
                                     genEquipRadioGroupsMIMOStatus2ndMMI 1.3.6.1.4.1.2281.10.7.8.4.3.1.4 integer read-only
MIMO interference in dB of the 2nd carrier.
                                     genEquipRadioGroupsMIMOStatus3rdMMI 1.3.6.1.4.1.2281.10.7.8.4.3.1.5 integer read-only
MIMO interference in dB of the 3rd carrier.
                                     genEquipRadioGroupsMIMOStatus4thMMI 1.3.6.1.4.1.2281.10.7.8.4.3.1.6 integer read-only
MIMO interference in dB of the 4th carrier.
                                     genEquipRadioGroupsMIMOStatusAdvancedState 1.3.6.1.4.1.2281.10.7.8.4.3.1.7 integer read-only
MIMO advanced state. Enumeration: 'init-retry': 2, 'half-capacity-master-failure': 17, 'half-capacity': 7, 'remote-has-no-master': 10, 'unsuitable-hw': 6, 'remote-master-failure': 9, 'slave-init': 12, 'master-failure': 8, 'self-mute-comm-fail-to-master': 15, 'slave-idle': 13, 'mute-slave': 11, 'disabled': 0, 'idle': 5, 'half-capacity-no-master': 16, 'init-retry-bringup': 4, 'initializing': 1, 'init-retry-checkup': 3, 'slave-mutted': 14.
                         genEquipRadioGroupsAbc 1.3.6.1.4.1.2281.10.7.8.5
                             genEquipRadioGroupsAbcAttrTable 1.3.6.1.4.1.2281.10.7.8.5.1 no-access
Multi Carrier ABC configuration table.
                                 genEquipRadioGroupsAbcAttrEntry 1.3.6.1.4.1.2281.10.7.8.5.1.1 no-access
Multi Carrier ABC configuration table.
                                     genEquipRadioGroupsAbcAttrIfIndex 1.3.6.1.4.1.2281.10.7.8.5.1.1.1 integer read-only
The interface-index of the ABC group
                                     genEquipRadioGroupsAbcAttrGroupName 1.3.6.1.4.1.2281.10.7.8.5.1.1.2 displaystring read-write
Textual description of the ABC group.
                                     genEquipRadioGroupsAbcAttrAdminState 1.3.6.1.4.1.2281.10.7.8.5.1.1.3 enabledisable read-write
The Administrative state of ABC radio group which decides if the Multi Carrier ABC group is enabled or disabled.
                                     genEquipRadioGroupsAbcAttrQnumberOfRadioMembers 1.3.6.1.4.1.2281.10.7.8.5.1.1.4 integer read-write
The number of radios that can be members of the Multi Carrier ABC group.
                                     genEquipRadioGroupsAbcAttrProtectionEnable 1.3.6.1.4.1.2281.10.7.8.5.1.1.5 enabledisable read-write
When Protection is Enabled protecion groups can be added to the Multi-carrier ABC group. When disabled regular channels can be attached.
                                     genEquipRadioGroupsAbcAttrHighPriEthernetBandwidth 1.3.6.1.4.1.2281.10.7.8.5.1.1.6 integer read-write
Bandwidth reserved for high priority ethernet in Kbps. Values range from from 0 (i.e. No high pri ethernet) to max capacity (I.e. no STM-1s) in Kbps.
                                     genEquipRadioGroupsAbcAttrQualityThreshold 1.3.6.1.4.1.2281.10.7.8.5.1.1.7 integer read-write
Members degrading below this threshold will be set to 'do not use' in the group.
                                     genEquipRadioGroupsAbcAttrRowStatus 1.3.6.1.4.1.2281.10.7.8.5.1.1.30 rowstatus read-write
This is the row status.
                             genEquipRadioGroupsAbcMembersTable 1.3.6.1.4.1.2281.10.7.8.5.2 no-access
Multi Carrier ABC members table.
                                 genEquipRadioGroupsAbcMembersEntry 1.3.6.1.4.1.2281.10.7.8.5.2.1 no-access
Multi Carrier ABC members table entry.
                                     genEquipRadioGroupsAbcMembersGroupIfIndex 1.3.6.1.4.1.2281.10.7.8.5.2.1.1 integer read-only
Integer representing the group interface ifindex
                                     genEquipRadioGroupsAbcMembersGroupId 1.3.6.1.4.1.2281.10.7.8.5.2.1.2 integer read-only
Integer representing the group interface ID.
                                     genEquipRadioGroupsAbcMembersChannel1MemberIfIndex 1.3.6.1.4.1.2281.10.7.8.5.2.1.3 integer read-write
IfIndex representing the group member connect to this ABC channel.
                                     genEquipRadioGroupsAbcMembersChannel1adminState 1.3.6.1.4.1.2281.10.7.8.5.2.1.4 enabledisable read-write
The Administrative state of an ABC channel.
                                     genEquipRadioGroupsAbcMembersChannel2MemberIfIndex 1.3.6.1.4.1.2281.10.7.8.5.2.1.5 integer read-write
IfIndex representing the group member connect to this ABC channel.
                                     genEquipRadioGroupsAbcMembersChannel2adminState 1.3.6.1.4.1.2281.10.7.8.5.2.1.6 enabledisable read-write
The Administrative state of an ABC channel.
                                     genEquipRadioGroupsAbcMembersChannel3MemberIfIndex 1.3.6.1.4.1.2281.10.7.8.5.2.1.7 integer read-write
IfIndex representing the group member connect to this ABC channel.
                                     genEquipRadioGroupsAbcMembersChannel3adminState 1.3.6.1.4.1.2281.10.7.8.5.2.1.8 enabledisable read-write
The Administrative state of an ABC channel.
                                     genEquipRadioGroupsAbcMembersChannel4MemberIfIndex 1.3.6.1.4.1.2281.10.7.8.5.2.1.9 integer read-write
IfIndex representing the group member connect to this ABC channel.
                                     genEquipRadioGroupsAbcMembersChannel4adminState 1.3.6.1.4.1.2281.10.7.8.5.2.1.10 enabledisable read-write
The Administrative state of an ABC channel.
                                     genEquipRadioGroupsAbcMembersChannel5MemberIfIndex 1.3.6.1.4.1.2281.10.7.8.5.2.1.11 integer read-write
IfIndex representing the group member connect to this ABC channel.
                                     genEquipRadioGroupsAbcMembersChannel5adminState 1.3.6.1.4.1.2281.10.7.8.5.2.1.12 enabledisable read-write
The Administrative state of an ABC channel.
                                     genEquipRadioGroupsAbcMembersChannel6MemberIfIndex 1.3.6.1.4.1.2281.10.7.8.5.2.1.13 integer read-write
IfIndex representing the group member connect to this ABC channel.
                                     genEquipRadioGroupsAbcMembersChannel6adminState 1.3.6.1.4.1.2281.10.7.8.5.2.1.14 enabledisable read-write
The Administrative state of an ABC channel.
                                     genEquipRadioGroupsAbcMembersChannel7MemberIfIndex 1.3.6.1.4.1.2281.10.7.8.5.2.1.15 integer read-write
IfIndex representing the group member connect to this ABC channel.
                                     genEquipRadioGroupsAbcMembersChannel7adminState 1.3.6.1.4.1.2281.10.7.8.5.2.1.16 enabledisable read-write
The Administrative state of an ABC channel.
                                     genEquipRadioGroupsAbcMembersChannel8MemberIfIndex 1.3.6.1.4.1.2281.10.7.8.5.2.1.17 integer read-write
IfIndex representing the group member connect to this ABC channel.
                                     genEquipRadioGroupsAbcMembersChannel8adminState 1.3.6.1.4.1.2281.10.7.8.5.2.1.18 enabledisable read-write
The Administrative state of an ABC channel.
                             genEquipRadioGroupsAbcStatusTable 1.3.6.1.4.1.2281.10.7.8.5.3 no-access
Multi Carrier ABC status table.
                                 genEquipRadioGroupsAbcStatusEntry 1.3.6.1.4.1.2281.10.7.8.5.3.1 no-access
Multi Carrier ABC status table entry.
                                     genEquipRadioGroupsAbcStatusIfIndex 1.3.6.1.4.1.2281.10.7.8.5.3.1.1 integer read-only
The interface-index of the ABC group
                                     genEquipRadioGroupsAbcStatusOperState 1.3.6.1.4.1.2281.10.7.8.5.3.1.2 downup read-only
The operational state of the ABC group as a WAN.
                                     genEquipRadioGroupsAbcStatusRemoteOperState 1.3.6.1.4.1.2281.10.7.8.5.3.1.3 downup read-only
The remote ABC groups operational state.
                                     genEquipRadioGroupsAbcStatusCurrentAggregatedCapacityRX 1.3.6.1.4.1.2281.10.7.8.5.3.1.4 integer read-only
The combined current RX throughput capacity of the ABC group in Kbps.
                                     genEquipRadioGroupsAbcStatusCurrentAggregatedCapacityTX 1.3.6.1.4.1.2281.10.7.8.5.3.1.5 integer read-only
The combined current TX throughput capacity of the ABC group in Kbps.
                                     genEquipRadioGroupsAbcStatusChannel1Operstate 1.3.6.1.4.1.2281.10.7.8.5.3.1.6 downup read-only
The operational state of the ABC channel.
                                     genEquipRadioGroupsAbcStatusChannel1Capacity 1.3.6.1.4.1.2281.10.7.8.5.3.1.7 integer read-only
The current throughput capacity of the ABC channel in Kbps.
                                     genEquipRadioGroupsAbcStatusChannel2Operstate 1.3.6.1.4.1.2281.10.7.8.5.3.1.8 downup read-only
The operational state of the ABC channel.
                                     genEquipRadioGroupsAbcStatusChannel2Capacity 1.3.6.1.4.1.2281.10.7.8.5.3.1.9 integer read-only
The current throughput capacity of the ABC channel in Kbps.
                                     genEquipRadioGroupsAbcStatusChannel3OperState 1.3.6.1.4.1.2281.10.7.8.5.3.1.10 downup read-only
The operational state of the ABC channel.
                                     genEquipRadioGroupsAbcStatusChannel3Capacity 1.3.6.1.4.1.2281.10.7.8.5.3.1.11 integer read-only
The current throughput capacity of the ABC channel in Kbps.
                                     genEquipRadioGroupsAbcStatusChannel4OperState 1.3.6.1.4.1.2281.10.7.8.5.3.1.12 downup read-only
The operational state of the ABC channel.
                                     genEquipRadioGroupsAbcStatusChannel4Capacity 1.3.6.1.4.1.2281.10.7.8.5.3.1.13 integer read-only
The current throughput capacity of the ABC channel in Kbps.
                                     genEquipRadioGroupsAbcStatusChannel5OperState 1.3.6.1.4.1.2281.10.7.8.5.3.1.14 downup read-only
The operational state of the ABC channel.
                                     genEquipRadioGroupsAbcStatusChannel5Capacity 1.3.6.1.4.1.2281.10.7.8.5.3.1.15 integer read-only
The current throughput capacity of the ABC channel in Kbps.
                                     genEquipRadioGroupsAbcStatusChannel6OperState 1.3.6.1.4.1.2281.10.7.8.5.3.1.16 downup read-only
The operational state of the ABC channel.
                                     genEquipRadioGroupsAbcStatusChannel6Capacity 1.3.6.1.4.1.2281.10.7.8.5.3.1.17 integer read-only
The current throughput capacity of the ABC channel in Kbps.
                                     genEquipRadioGroupsAbcStatusChannel7OperState 1.3.6.1.4.1.2281.10.7.8.5.3.1.18 downup read-only
The operational state of the ABC channel.
                                     genEquipRadioGroupsAbcStatusChannel7Capacity 1.3.6.1.4.1.2281.10.7.8.5.3.1.19 integer read-only
The current throughput capacity of the ABC channel in Kbps.
                                     genEquipRadioGroupsAbcStatusChannel8OperState 1.3.6.1.4.1.2281.10.7.8.5.3.1.20 downup read-only
The operational state of the ABC channel.
                                     genEquipRadioGroupsAbcStatusChannel8Capacity 1.3.6.1.4.1.2281.10.7.8.5.3.1.21 integer read-only
The current throughput capacity of the ABC channel in Kbps.
                             genEquipStm1AbcAttrTable 1.3.6.1.4.1.2281.10.7.8.5.5 no-access
Multi Carrier ABC stm1 table.
                                 genEquipStm1AbcAttrEntry 1.3.6.1.4.1.2281.10.7.8.5.5.1 no-access
Multi Carrier ABC stm1 table entry.
                                     genEquipStm1AbcAttrIfIndex 1.3.6.1.4.1.2281.10.7.8.5.5.1.1 integer read-only
The interface-index of the ABC group
                                     genEquipStm1AbcAttrGroupId 1.3.6.1.4.1.2281.10.7.8.5.5.1.2 integer read-only
Integer representing the group interface ID.
                                     genEquipStm1AbcAttrNumberOfMembers 1.3.6.1.4.1.2281.10.7.8.5.5.1.3 integer read-write
The number of STM-1/OC-3 channels that can be members of the Multi Carrier ABC group.
                                     genEquipStm1AbcAttrPri1IfIndex 1.3.6.1.4.1.2281.10.7.8.5.5.1.4 integer read-write
Location of the highest priority STM-1/OC-3 interface.
                                     genEquipStm1AbcAttrPri2IfIndex 1.3.6.1.4.1.2281.10.7.8.5.5.1.5 integer read-write
Location of the highest priority STM-1/OC-3 interface.
                                     genEquipStm1AbcAttrPri3IfIndex 1.3.6.1.4.1.2281.10.7.8.5.5.1.6 integer read-write
Location of the highest priority STM-1/OC-3 interface.
                                     genEquipStm1AbcAttrPri4IfIndex 1.3.6.1.4.1.2281.10.7.8.5.5.1.7 integer read-write
Location of the highest priority STM-1/OC-3 interface.