INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB: View SNMP OID List / Download MIB
VENDOR: INTEL CORPORATION
Home | MIB: INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
multiFlexServerPwrMibModule | 1.3.6.1.4.1.343.2.19.1.1.1.17 |
Power Supply Module of the Multi-Flex Server |
||
pwrSupplyGroup | 1.3.6.1.4.1.343.2.19.1.2.2.2.17 |
Description. |
||
maxPwrSupplies | 1.3.6.1.4.1.343.2.19.1.2.10.17 | unsigned32 | read-only |
Maximum number of Power Supply FRUs (including Power Supply Blanks and unknown) possible in this chassis. |
numOfPwrSupplies | 1.3.6.1.4.1.343.2.19.1.2.10.27 | integer32 | read-only |
The number of Power Supplies (excludes blanks & unknown Frus in power supply slots). |
numOfPwrBlanks | 1.3.6.1.4.1.343.2.19.1.2.10.28 | integer32 | read-only |
The number of Power Supply Blanks (Fan only) in the system. |
numOfPwrUnknowns | 1.3.6.1.4.1.343.2.19.1.2.10.29 | integer32 | read-only |
The number of FRUs occupying power supply slots that are neither recognized as power supplies, nor blanks. |
pwrSupplyPresenceMask | 1.3.6.1.4.1.343.2.19.1.2.10.37 | displaystring | read-only |
ASCII representation of bit string reflecting the presence of a recognized power supply in the power supply slots with the left most 'bit' being bit 1 and maxPwrSupplies bits being represented. This excludes fan blanks and unrecognized FRUs. Thus, '0101' would express that power supply FRUs 2 & 4 are recognized power supplies present |
pwrSupplyBlankPresenceMask | 1.3.6.1.4.1.343.2.19.1.2.10.38 | displaystring | read-only |
ASCII representation of bit string reflecting the presence of a recognized fan blanks in the power supply slots with the left most 'bit' being bit 1 and maxPwrSupplies bits being represented. This excludes both recognized and unrecognized power supplies. Thus, '0010' would express that power supply FRU 3 is a recognized fan blank present |
pwrSupplyUnknownPresenceMask | 1.3.6.1.4.1.343.2.19.1.2.10.39 | displaystring | read-only |
ASCII representation of bit string reflecting the presence of a unrecognized FRUs in the power supply slots with the left most 'bit' being bit 1 and maxPwrSupplies bits being represented. This excludes recognized power supplies and fan blanks. Thus, '1000' would express that an unrecognized FRU is in the power supply slot 1 is present |
pwrSupplies | 1.3.6.1.4.1.343.2.19.1.2.10.207 |
Container for Power Supply specific information as well as all components logically contained within. |
||
pwrSupplyTable | 1.3.6.1.4.1.343.2.19.1.2.10.207.1 | no-access |
Each row describes a Power Supply FRU in the chassis |
|
1.3.6.1.4.1.343.2.19.1.2.10.207.1.1 | no-access |
.. |
||
pwrSupplyIndex | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.1 | index | read-only |
column used to identify a particular Power Supply. |
pwrSupplyPresence | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.2 | presence | read-only |
Flag whether something is occupying the the power supply slot (being either a power supply, a power supply blank, or unknown device) pwrSupplyType within this row should be consulted to determine what is occupying the slot. |
pwrSupplyVendor | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.3 | displaystring | read-only |
Device manufacturer |
pwrSupplyMfgDate | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.4 | displaystring | read-only |
Manufacture date/time |
pwrSupplyDeviceName | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.5 | displaystring | read-only |
Device Name |
pwrSupplyPart | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.6 | idrombinary16 | read-only |
Device Part Number |
pwrSupplySerialNo | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.7 | idrombinary16 | read-only |
Device Serial Number |
pwrSupplyMaximumPower | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.8 | power | read-only |
Static maximum power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) -1 - Maximum power generation/consumption not known or specified |
pwrSupplyNominalPower | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.9 | power | read-only |
Static Nominal power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) -1 - Nominal power generation/consumption not known or specified |
pwrSupplyAssetTag | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.10 | idrombinary16 | read-only |
Asset Tag # of device |
pwrSupplyPowerLed | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.11 | powerledstates | read-only |
State of the Power LED on the Power Supply |
pwrSupplyFaultLed | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.12 | faultledstates | read-only |
State of the Fault LED on the Power Supply (and optionally intiate identification) |
pwrSupplyOpCodeVersion | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.13 | displaystring | read-only |
BMC Firmware version on the Fan Blank (only) |
pwrSupplyBootBlockVersion | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.14 | displaystring | read-only |
BMC Firmware version on the Fan Blank (only) |
pwrSupplyType | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.15 | integer | read-only |
Enumeration telling what kind of power supply FRU is in the slot Enumeration: 'notApplicable': -32, 'powerSuppy': 1, 'powerSupplyBank': 2, 'unknown': -16. |
pwrSupplyNumOfFans | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.16 | int32withexception | read-only |
Number of Fans contained within this FRU May be static data given the FRU |
pwrSupplyInletTemperature | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.17 | int32withexception | read-only |
Power supply Fan blank FRU Inlet Temperature in Degrees Celsius (not applicable to power supplies that do not have an Inlet Temperature |
pwrSupplyOutputVdc | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.18 | int32withexception | read-only |
Power supply's output voltage in millivolts notApplicable - if a power supply fan blank, or isn't present unknown - if device type is unknown |
pwrSupplyOutputAmp | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.19 | int32withexception | read-only |
Power supply's output amperage in milliamps notApplicable - if a power supply fan blank, or isn't present unknown - if device type is unknown |
pwrSupplyOutputPickAmp | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.20 | int32withexception | read-only |
Power supply's output pick amperage in milliiamps notApplicable - if a power supply fan blank, or isn't present unknown - if device type is unknown |
pwrSupplyHotspotTemp | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.21 | int32withexception | read-only |
Power supply's Hotspot Temperature in degrees Celsius degrees Celsius - when power supply is present notApplicable - if a power supply fan blank, or isn't present unknown - if device type is unknown |
pwrSupplyEmbTemp | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.22 | int32withexception | read-only |
Power supply's EMB Temperature in degrees Celsius degrees Celsius - when power supply is present notApplicable - if a power supply fan blank, or isn't present unknown - if device type is unknown |
pwrSupplyStatus | 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.23 | bits | read-only |
Power supply's status bits (power supply only) This is used to provide multiple enumerations (by bits) of the status. E.g., powerSupplyOn(2) powerOK(3). Bits: 'overTemp': 5, 'supplyFault': 7, 'unused': 4, 'overCurrent': 6, 'powerSupplyOn': 2, 'unused2': 1, 'unused1': 0, 'powerOK': 3. |
pwrSupplyFanTable | 1.3.6.1.4.1.343.2.19.1.2.10.207.2 | no-access |
Each row describes a Fan in a Fan FRU (indexed by the Fan FRU and by individual Fan) Current, this should include the 3 Fan FRUs (the two system Fan FRUs and the I/O Fan FRU) The number of Fans is dependent upon the FRU (see pwrSupplyFanFruNumOfFans in the fanFruTable for a particular FRU) |
|
1.3.6.1.4.1.343.2.19.1.2.10.207.2.1 | no-access |
.. |
||
pwrSupplyFanIndex | 1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.1 | index | read-only |
which pwrSupplyFan within a FRU we're talking about |
pwrSupplyFanRpmMinimum | 1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.2 | integer32 | read-only |
Minimum settable RPM Potentially to be removed - See Murali/Niel |
pwrSupplyFanRpmMaximum | 1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.3 | integer32 | read-only |
Maximum settable RPM Potentially to be removed - See Murali/Niel |
pwrSupplyFanRpmReading | 1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.4 | integer | read-only |
Fan's current RPM reading: 0 - Fan not spinning unknown - Indeterminate data (no communications, or unknown device present) notApplicable - Not present Enumeration: 'notApplicable': -32, 'notspinning': 0, 'unknown': -16. |