HUAWEI-TRILL-CONF-MIB: View SNMP OID List / Download MIB

VENDOR: HUAWEI


 Home MIB: HUAWEI-TRILL-CONF-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 hwTrill 1.3.6.1.4.1.2011.5.25.331
The HUAWEI PRIVATE MIB contains objects belonging to processes of the TRILL protocol existing on the system. It defines the model used to represent data that exists elsewhere in the system and on peripheral devices. There are no constraints on this MIB.
         hwTrillConf 1.3.6.1.4.1.2011.5.25.331.1
             hwTrillMibObjects 1.3.6.1.4.1.2011.5.25.331.1.1
                 hwTrillBaseTable 1.3.6.1.4.1.2011.5.25.331.1.1.1 no-access
This table describes TRILL instance information.
                     hwTrillBaseEntry 1.3.6.1.4.1.2011.5.25.331.1.1.1.1 no-access
Description.
                         hwTrillInstanceID 1.3.6.1.4.1.2011.5.25.331.1.1.1.1.1 unsigned32 read-write
Trill instance id.
                         hwTrillSysID 1.3.6.1.4.1.2011.5.25.331.1.1.1.1.2 systemid read-write
Trill system id.
                         hwTrillRemainingLifetime 1.3.6.1.4.1.2011.5.25.331.1.1.1.1.3 unsigned32 read-write
Trill remaining-lifetime of LSP.
                         hwTrillPduLspId 1.3.6.1.4.1.2011.5.25.331.1.1.1.1.4 linkstatepduid read-write
Trill LSP id.
                 hwTrillNicknameTable 1.3.6.1.4.1.2011.5.25.331.1.1.2 no-access
This table describes nickname information about an TRILL network.
                     hwTrillNicknameEntry 1.3.6.1.4.1.2011.5.25.331.1.1.2.1 no-access
Description.
                         hwTrillNickname 1.3.6.1.4.1.2011.5.25.331.1.1.2.1.2 unsigned32 read-write
Trill nickname.
                         hwTrillPriority 1.3.6.1.4.1.2011.5.25.331.1.1.2.1.3 unsigned32 read-write
Trill priority.
                 hwTrillAuthenticationTable 1.3.6.1.4.1.2011.5.25.331.1.1.3 no-access
This table describes information on TRILL ports' authentification modes.
                     hwTrillAuthenticationEntry 1.3.6.1.4.1.2011.5.25.331.1.1.3.1 no-access
Description.
                         hwTrillSysInstance 1.3.6.1.4.1.2011.5.25.331.1.1.3.1.1 unsigned32 read-write
Trill instance id.
                         hwTrillCircIfIndex 1.3.6.1.4.1.2011.5.25.331.1.1.3.1.2 integer32 read-write
Trill circuit interface index.
                         hwTrillPduFragment 1.3.6.1.4.1.2011.5.25.331.1.1.3.1.3 octet string no-access
64-byte PDU fragment.
             hwTrillConfGroups 1.3.6.1.4.1.2011.5.25.331.1.2
                 hwTrillBaseEntryGroup 1.3.6.1.4.1.2011.5.25.331.1.2.1
Description.
                 hwTrillNicknameGroup 1.3.6.1.4.1.2011.5.25.331.1.2.2
Description.
                 hwTrillTrapsGroup 1.3.6.1.4.1.2011.5.25.331.1.2.3
Description.
                 hwTrillAuthenticationGroup 1.3.6.1.4.1.2011.5.25.331.1.2.4
Description.
             hwTrillTraps 1.3.6.1.4.1.2011.5.25.331.1.3
                 hwTrillNicknameConflict 1.3.6.1.4.1.2011.5.25.331.1.3.1
The local nickname conflicted with another nickname.
                 hwTrillNicknameConflictClear 1.3.6.1.4.1.2011.5.25.331.1.3.2
The local nickname conflict was cleared.
                 hwTrillAuthenticationFailure 1.3.6.1.4.1.2011.5.25.331.1.3.3
The alarm is generated if the device receives a PDU carrying an authentication password that is different from the local one. The PDU fragment is displayed in the alarm, helping network administrators locate the device that sent the PDU.
                 hwTrillAuthenticationTypeFailure 1.3.6.1.4.1.2011.5.25.331.1.3.4
The alarm is generated if the device receives a PDU carrying an authentication mode that is different from the local one. The PDU fragment is displayed in the alarm, helping network administrators locate the device that sent the PDU.
                 hwTrillLspRemainingLifetimeRefresh 1.3.6.1.4.1.2011.5.25.331.1.3.5
This object indicates that the Remaining Lifetime of a received LSP is less than 60s.
             hwTrillCompliances 1.3.6.1.4.1.2011.5.25.331.1.5
                 hwTrillModuleFullCompliance 1.3.6.1.4.1.2011.5.25.331.1.5.1
Description.