Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 hh3cdlsw 1.3.6.1.4.1.25506.8.37
private MIB for dlsw
       hh3cdlswNode 1.3.6.1.4.1.25506.8.37.1
           hh3cdlswNodeVersion 1.3.6.1.4.1.25506.8.37.1.1 octet string read-only
This value identifies the particular version of the DLSw standard supported by this DLSw. The first octet is a hexadecimal value representing the DLSw standard Version number of this DLSw, and the second is a hexadecimal value representing the DLSw standard Release number. This information is reported in DLSw Capabilities Exchange.
           hh3cdlswNodeVendorID 1.3.6.1.4.1.25506.8.37.1.2 octet string read-only
The value identifies the manufacturer's IEEE-assigned organizationally Unique Identifier (OUI) of this DLSw. This information is reported in DLSw Capabilities Exchange.
           hh3cdlswNodeVersionString 1.3.6.1.4.1.25506.8.37.1.3 displaystring read-only
This string gives product-specific information about this DLSw (e.g., product name, code release and fix level). This flows in Capabilities Exchange messages.
           hh3cdlswNodeStdPacingSupport 1.3.6.1.4.1.25506.8.37.1.4 integer read-only
Circuit pacing, as defined in the DLSw Standard, allows each of the two DLSw nodes on a circuit to control the amount of data the other is permitted to send to them. This object reflects the level of support the DLSw node has for this protocol. (1) means the node has no support for the standard circuit pacing flows; it may use RFC 1434+ methods only, or a proprietary flow control scheme. (2) means the node supports the standard scheme and can vary the window sizes it grants as a data receiver. (3) means the node supports the standard scheme but never varies its receive window size. Enumeration: 'fixedRcvWindow': 3, 'none': 1, 'adaptiveRcvWindow': 2, 'unknown': 65535.
           hh3cdlswNodeStatus 1.3.6.1.4.1.25506.8.37.1.5 integer read-write
The status of the DLSw part of the system. Enumeration: 'active': 1, 'inactive': 2.
           hh3cdlswNodeVirtualSegmentLFSize 1.3.6.1.4.1.25506.8.37.1.6 lfsize read-write
The largest frame size (including DLC header and info field but not any MAC-level or framing octets) this DLSw can forward on any path through itself. This object can represent any box- level frame size forwarding restriction (e.g., from the use of fixed-size buffers). Some DLSw implementations will have no such restriction. This value will affect the LF size of circuits during circuit creation. The LF size of an existing circuit can be found in the RIF (Routing Information Field).
           hh3cdlswNodeLocalAddr 1.3.6.1.4.1.25506.8.37.1.7 ipaddress read-write
Local peer ip address.
           hh3cdlswNodePriority 1.3.6.1.4.1.25506.8.37.1.8 integer read-write
The priority value of local peer. 65535 expresses the value is unknown
           hh3cdlswNodeInitWindow 1.3.6.1.4.1.25506.8.37.1.9 integer read-write
The vlaue of init-window. 65535 expresses the value is unknown
           hh3cdlswNodeKeepAlive 1.3.6.1.4.1.25506.8.37.1.10 integer read-write
The vlaue of keepalive interval. 65535 expresses the value is unknown
           hh3cdlswNodeMaxWindow 1.3.6.1.4.1.25506.8.37.1.11 integer read-write
The value of max-window. 65535 expresses the value is unknown
           hh3cdlswNodePermitDynamic 1.3.6.1.4.1.25506.8.37.1.12 integer read-write
To accept connections from non-configured remote peers when permit-dynamic is setted. Enumeration: 'unknown': 65535, 'permit-dynamic': 1, 'forbid-dynamic': 2.
           hh3cdlswNodeConnTimeout 1.3.6.1.4.1.25506.8.37.1.13 integer read-write
Define connected state timer(The unit is a thousandth of a second).
           hh3cdlswNodeLocalPendTimeout 1.3.6.1.4.1.25506.8.37.1.14 integer read-write
Define connected state timer(The unit is a thousandth of a second).
           hh3cdlswNodeRemotePendTimeout 1.3.6.1.4.1.25506.8.37.1.15 integer read-write
Define connected state timer(The unit is a thousandth of a second).
           hh3cdlswNodeSnaCacheTimeout 1.3.6.1.4.1.25506.8.37.1.16 integer read-write
Define connected state timer(The unit is a thousandth of a second).
           hh3cdlswTrapControl 1.3.6.1.4.1.25506.8.37.1.20
                 hh3cdlswTrapCntlState 1.3.6.1.4.1.25506.8.37.1.20.1 integer read-write
It is used to indicate whether the DLSw is permitted to emit traps. Enumeration: 'disabled': 2, 'enabled': 1.
       hh3cdlswTConn 1.3.6.1.4.1.25506.8.37.2
           hh3cdlswRemotePeerTable 1.3.6.1.4.1.25506.8.37.2.1 no-access
A list of tcp transport connections.
               hh3cdlswRemotePeerEntry 1.3.6.1.4.1.25506.8.37.2.1.1 no-access
A list of remote peer information
                   hh3cdlswRemotePeerAddr 1.3.6.1.4.1.25506.8.37.2.1.1.1 ipaddress read-only
The remote peer address for this transport connection.
                   hh3cdlswRemotePeerVersion 1.3.6.1.4.1.25506.8.37.2.1.1.2 octet string read-only
This value identifies which version (first octet) and release (second octet) of the DLSw standard is supported by this partner DLSw. This information is obtained from a DLSw capabilities exchange message received from the partner DLSw. A string of zero length is returned before a Capabilities Exchange message is received, or if one is never received. A conceptual row with a hh3cdlswTConnOperState of `connected' but a zero length partner version indicates that the partner is a non-standard DLSw partner. If an implementation chooses to keep hh3cdlswTConnOperEntrys in the `disconnected' state, this value should remain unchanged.
                   hh3cdlswRemotePeerVendorID 1.3.6.1.4.1.25506.8.37.2.1.1.3 octet string read-only
This value identifies the IEEE-assigned organizationally Unique Identifier (OUI) of the maker of this partner DLSw. This information is obtained from a DLSw capabilities exchange message received from the partner DLSw. A string of zero length is returned before a Capabilities Exchange message is received, or if one is never received. If an implementation chooses to keep hh3cdlswTConnOperEntrys in the `disconnected' state, this value should remain unchanged.
                   hh3cdlswRemotePeerPaceWindInit 1.3.6.1.4.1.25506.8.37.2.1.1.4 integer read-only
The value of the partner initial receive pacing window. This is our initial send pacing window for all new circuits on this transport connection, as modified and granted by the first flow control indication the partner sends on each circuit. This information is obtained from a DLSw capabilities exchange message received from the partner DLSw. A value of zero is returned before a Capabilities Exchange message is received, or if one is never received. If an implementation chooses to keep hh3cdlswTConnOperEntrys in the `disconnected' state, this value should remain unchanged.
                   hh3cdlswRemotePeerVersionString 1.3.6.1.4.1.25506.8.37.2.1.1.5 displaystring read-only
This value identifies the particular product version (e.g., product name, code level, fix level) of this partner DLSw. The format of the actual version string is vendor-specific. This information is obtained from a DLSw capabilities exchange message received from the partner DLSw. A string of zero length is returned before a Capabilities Exchange message is received, if one is never received, or if one is received but it does not contain a version string. If an implementation chooses to keep hh3cdlswTConnOperEntrys in the `disconnected' state, this value should remain unchanged.
                   hh3cdlswRemotePeerIsConfig 1.3.6.1.4.1.25506.8.37.2.1.1.6 integer read-only
The current remote peer is configrured when the value is 'yes'. Enumeration: 'yes': 1, 'no': 2.
                   hh3cdlswRemotePeerCost 1.3.6.1.4.1.25506.8.37.2.1.1.7 integer read-write
The cost for remote peer.
                   hh3cdlswRemotePeerKeepAlive 1.3.6.1.4.1.25506.8.37.2.1.1.8 integer read-write
The keepalive interval value.
                   hh3cdlswRemotePeerLf 1.3.6.1.4.1.25506.8.37.2.1.1.9 lfsize read-write
The the largest frame size.
                   hh3cdlswRemotePeerTcpQueneMax 1.3.6.1.4.1.25506.8.37.2.1.1.10 integer read-write
The max tcp queue value.
                   hh3cdlswRemotePeerHaveBackup 1.3.6.1.4.1.25506.8.37.2.1.1.11 integer read-only
There is another remote peer whitch is configrued as the backup of the current remote peer . Enumeration: 'yes': 1, 'no': 2.
                   hh3cdlswRemotePeerIsBackup 1.3.6.1.4.1.25506.8.37.2.1.1.12 integer read-only
The current remote peer is configrued as the backup of another configured remote peer . Enumeration: 'yes': 1, 'no': 2.
                   hh3cdlswRemotePeerBackupAddr 1.3.6.1.4.1.25506.8.37.2.1.1.13 ipaddress read-only
It is the IP ADDRESS of an configured remote peer of whitch the current remote peer is configrued as the backup
                   hh3cdlswRemotePeerLinger 1.3.6.1.4.1.25506.8.37.2.1.1.14 integer read-write
Buckup Peer linger
                   hh3cdlswRemotePeerLinkState 1.3.6.1.4.1.25506.8.37.2.1.1.15 integer read-only
The state of this tcp transport connection. Enumeration: 'disconnected': 6, 'connected': 3, 'connecting': 1, 'quiescing': 4, 'initCapExchange': 2, 'disconnecting': 5.
                   hh3cdlswRemotePeerRecvPacks 1.3.6.1.4.1.25506.8.37.2.1.1.16 counter32 read-only
The number of Switch-to-Switch Protocol (SSP) messages received on this tcp transport connection.
                   hh3cdlswRemotePeerSendPacks 1.3.6.1.4.1.25506.8.37.2.1.1.17 counter32 read-only
The number of Switch-to-Switch Protocol (SSP) messages sent on this tcp transport connection.
                   hh3cdlswRemotePeerDrops 1.3.6.1.4.1.25506.8.37.2.1.1.18 counter32 read-only
The number of Switch-to-Switch Protocol (SSP) messages dropped on this tcp transport connection.
                   hh3cdlswRemotePeerUptime 1.3.6.1.4.1.25506.8.37.2.1.1.19 counter32 read-only
The amount of time (in seconds ) since this transport connection last entered the 'connected' state.
                   hh3cdlswRemotePeerEntryStatus 1.3.6.1.4.1.25506.8.37.2.1.1.20 entrystatus read-write
This object is used by the manager to create or delete the row entry in the hh3cdlswRemotePeerTable following the EntryStatus textual convention.
       hh3cdlswBridgeGroup 1.3.6.1.4.1.25506.8.37.3
           hh3cdlswBridgeTable 1.3.6.1.4.1.25506.8.37.3.1 no-access
The list of bridge group whitch has been created.
               hh3cdlswBridgeEntry 1.3.6.1.4.1.25506.8.37.3.1.1 no-access
The list of bridge information
                   hh3cdlswBridgeNum 1.3.6.1.4.1.25506.8.37.3.1.1.1 integer read-only
This value identifies the bridge number .
                   hh3cdlswBridgeStatus 1.3.6.1.4.1.25506.8.37.3.1.1.2 createlineflag read-write
This value whitch is equal to 'DeleteLine' identifies to delete a conceptual raw.
           hh3cdlswBridgeIfTable 1.3.6.1.4.1.25506.8.37.3.2 no-access
The list of interfaces on which DLSw is active.
               hh3cdlswBridgeIfEntry 1.3.6.1.4.1.25506.8.37.3.2.1 no-access
The list of bridge interface information
                   hh3cdlswBridgeIfBriGru 1.3.6.1.4.1.25506.8.37.3.2.1.1 integer read-write
This value identifies the bridge number attached to the interface.
                   hh3cdlswBridgeIfName 1.3.6.1.4.1.25506.8.37.3.2.1.2 displaystring read-only
The name of the interface.
                   hh3cdlswBridgeIfStatus 1.3.6.1.4.1.25506.8.37.3.2.1.3 entrystatus read-write
This value whitch is equal to 'invalid' identifies to delete a conceptual raw
       hh3cdlswLocDirectory 1.3.6.1.4.1.25506.8.37.4
           hh3cdlswLocMacTable 1.3.6.1.4.1.25506.8.37.4.1 no-access
This table contains locations of MAC addresses. They are local and reachable
               hh3cdlswLocMacEntry 1.3.6.1.4.1.25506.8.37.4.1.1 no-access
                   hh3cdlswLocMacHashIndex 1.3.6.1.4.1.25506.8.37.4.1.1.1 integer read-only
The hash value.
                   hh3cdlswLocMacHashIndexSeqNum 1.3.6.1.4.1.25506.8.37.4.1.1.2 integer read-only
The sequence num with smae hash value.
                   hh3cdlswLocMacMac 1.3.6.1.4.1.25506.8.37.4.1.1.3 macaddressnc read-only
The MAC address.
                   hh3cdlswLocMacLocalInterfaceName 1.3.6.1.4.1.25506.8.37.4.1.1.4 displaystring read-only
The value is the interface name when hh3cdlswLocMacLocationType is 'local'.
       hh3cdlswCircuit 1.3.6.1.4.1.25506.8.37.5
           hh3cdlswCircuitTable 1.3.6.1.4.1.25506.8.37.5.1 no-access
This table is the circuit representation in the DLSw entity. Virtual data links are used to represent any internal end stations. There is a conceptual row associated with each data link. Thus, for circuits without an intervening transport connection, there are two conceptual rows for each circuit. The table consists of the circuits being established, established, and as an implementation option, circuits that have been disconnected. For circuits carried over transport connections, an entry is created after the CUR_cs was sent or received. For circuits between two locally attached devices, or internal virtual MAC addresses, an entry is created when the equivalent of CUR_cs sent/received status is reached. End station 1 (S1) and End station 2 (S2) are used to represent the two end stations of the circuit. S1 is always an end station which is locally attached. S2 may be locally attached or remote. If it is locally attached, the circuit will be represented by two rows indexed by (A, B) and (B, A) where A & B are the relevant MACs/SAPs. The table may be used to store the causes of disconnection of circuits. It is recommended that the oldest disconnected circuit entry be removed from this table when the memory space of disconnected circuits is needed.
               hh3cdlswCircuitEntry 1.3.6.1.4.1.25506.8.37.5.1.1 no-access
the list of circuit information
                   hh3cdlswCircuitS1CircuitId 1.3.6.1.4.1.25506.8.37.5.1.1.1 integer read-only
The Circuit ID assigned by this DLSw node to this circuit. The first four octets are the DLC port Id, and the second four octets are the Data Link Correlator. If the DLSw SSP was not used to establish this circuit, the value will be a string of zero length.
                   hh3cdlswCircuitS1Mac 1.3.6.1.4.1.25506.8.37.5.1.1.2 macaddressnc read-only
The MAC Address of End Station 1 (S1) used for this circuit.
                   hh3cdlswCircuitS1Sap 1.3.6.1.4.1.25506.8.37.5.1.1.3 octet string read-only
The SAP at End Station 1 (S1) used for this circuit.
                   hh3cdlswCircuitS2Mac 1.3.6.1.4.1.25506.8.37.5.1.1.4 macaddressnc read-only
The MAC Address of End Station 2 (S2) used for this circuit.
                   hh3cdlswCircuitS2Sap 1.3.6.1.4.1.25506.8.37.5.1.1.5 octet string read-only
The SAP at End Station 2 (S2) used for this circuit.
                   hh3cdlswCircuitS1IfIndex 1.3.6.1.4.1.25506.8.37.5.1.1.6 integer read-only
The ifEntry index of the local interface through which S1 can be reached.
                   hh3cdlswCircuitS1Ifname 1.3.6.1.4.1.25506.8.37.5.1.1.7 displaystring read-only
The name of the interface whose Ifdex is hh3cdlswCircuitS1IfIndex.
                   hh3cdlswCircuitS1DlcType 1.3.6.1.4.1.25506.8.37.5.1.1.8 dlctype read-only
The DLC protocol in use between the DLSw node and S1.
                   hh3cdlswCircuitS2TAddress 1.3.6.1.4.1.25506.8.37.5.1.1.9 ipaddress read-only
If the location of End Station 2 is remote, this object contains the address of the partner DLSw, else it will be an OCTET STRING of zero length.
                   hh3cdlswCircuitS2CircuitId 1.3.6.1.4.1.25506.8.37.5.1.1.10 integer read-only
The Circuit ID assigned to this circuit by the partner DLSw node. The first four octets are the DLC port Id, and the second four octets are the Data Link Correlator. If the DLSw SSP was not used to establish this circuit, the value will be a string of zero length.
                   hh3cdlswCircuitOrigin 1.3.6.1.4.1.25506.8.37.5.1.1.11 integer read-only
This object specifies which of the two end stations initiated the establishment of this circuit. Enumeration: 's2': 2, 's1': 1.
                   hh3cdlswCircuitEntryTime 1.3.6.1.4.1.25506.8.37.5.1.1.12 timeticks read-only
The amount of time (in hundredths of a second) since this circuit table conceptual row was created.
                   hh3cdlswCircuitStateTime 1.3.6.1.4.1.25506.8.37.5.1.1.13 timeticks read-only
The amount of time (in hundredths of a second) since this circuit entered the current state.
                   hh3cdlswCircuitState 1.3.6.1.4.1.25506.8.37.5.1.1.14 integer read-only
The current state of this circuit. The agent, implementation specific, may choose to keep entries for some period of time after circuit disconnect, so the manager can gather the time and cause of disconnection. While all of the specified values may be returned from a GET operation, the only SETable value is `disconnectPending'. When this value is set, DLSw should perform the appropriate action given its previous state (e.g., send HALT_DL if the state was `connected') to bring the circuit down to the `disconnected' state. Both the partner DLSw and local end station(s) should be notified as appropriate. This MIB provides no facility to re-establish a disconnected circuit, because in DLSw this should be an end station-driven function. Enumeration: 'circuitRestart': 12, 'haltPendingNoack': 11, 'contactPending': 7, 'disconnected': 1, 'circuitEstablished': 5, 'haltPending': 10, 'restartPending': 13, 'resolvePending': 3, 'connected': 8, 'circuitStart': 2, 'circuitPending': 4, 'connectPending': 6, 'disconnectPending': 9.
                   hh3cdlswCircuitFCSendGrantedUnits 1.3.6.1.4.1.25506.8.37.5.1.1.15 integer read-only
The number of paced SSP messages that this DLSw is currently authorized to send on this circuit before it must stop and wait for an additional flow control indication from the partner DLSw. The value zero should be returned if this circuit is not running the DLSw pacing protocol.
                   hh3cdlswCircuitFCSendCurrentWndw 1.3.6.1.4.1.25506.8.37.5.1.1.16 integer read-only
The current window size that this DLSw is using in its role as a data sender. This is the value by which this DLSw would increase the number of messages it is authorized to send, if it were to receive a flow control indication with the bits specifying `repeat window'. The value zero should be returned if this circuit is not running the DLSw pacing protocol.
                   hh3cdlswCircuitFCRecvGrantedUnits 1.3.6.1.4.1.25506.8.37.5.1.1.17 integer read-only
The current number of paced SSP messages that this DLSw has authorized the partner DLSw to send on this circuit before the partner DLSw must stop and wait for an additional flow control indication from this DLSw. The value zero should be returned if this circuit is not running the DLSw pacing protocol.
                   hh3cdlswCircuitFCRecvCurrentWndw 1.3.6.1.4.1.25506.8.37.5.1.1.18 integer read-only
The current window size that this DLSw is using in its role as a data receiver. This is the number of additional paced SSP messages that this DLSw would be authorizing its DLSw partner to send, if this DLSw were to send a flow control indication with the bits specifying `repeat window'. The value zero should be returned if this circuit is not running the DLSw pacing protocol.
       hh3cdlswSdlc 1.3.6.1.4.1.25506.8.37.6
           hh3cdlswSdlcPortTable 1.3.6.1.4.1.25506.8.37.6.1 no-access
The table defines parameters for the interfaces with the encapunation of SDLC.
               hh3cdlswSdlcPortEntry 1.3.6.1.4.1.25506.8.37.6.1.1 no-access
                   hh3cdlswSdlcPortSerialName 1.3.6.1.4.1.25506.8.37.6.1.1.1 displaystring read-only
The name of serial port.
                   hh3cdlswSdlcPortEncap 1.3.6.1.4.1.25506.8.37.6.1.1.2 integer read-only
The encapunation of the interface. Enumeration: 'ppp': 2, 'other': 3, 'sdlc': 1.
                   hh3cdlswSdlcPortRole 1.3.6.1.4.1.25506.8.37.6.1.1.3 integer read-write
The SDLC role of interface. Enumeration: 'primary': 1, 'seconday': 2, 'norole': 3.
                   hh3cdlswSdlcPortVmac 1.3.6.1.4.1.25506.8.37.6.1.1.4 macaddressnc read-write
Define virtual mac address.
                   hh3cdlswSdlcPortHoldq 1.3.6.1.4.1.25506.8.37.6.1.1.5 integer read-write
Size of hold queue.
                   hh3cdlswSdlcPortK 1.3.6.1.4.1.25506.8.37.6.1.1.6 integer read-write
Size of local send window.
                   hh3cdlswSdlcPortModule 1.3.6.1.4.1.25506.8.37.6.1.1.7 integer read-write
Size of modulus. Enumeration: 'm128': 128, 'm8': 8.
                   hh3cdlswSdlcPortN1 1.3.6.1.4.1.25506.8.37.6.1.1.8 integer read-write
Max number of bits for incoming frames.
                   hh3cdlswSdlcPortN2 1.3.6.1.4.1.25506.8.37.6.1.1.9 integer read-write
Number of timers to retry an operation.
                   hh3cdlswSdlcPortPollPauseTimer 1.3.6.1.4.1.25506.8.37.6.1.1.10 integer read-write
Time between polls for each secondary SDLC station. The unit is thousandth of a second.
                   hh3cdlswSdlcPortSimultaneousEnable 1.3.6.1.4.1.25506.8.37.6.1.1.11 integer read-write
Activate SDLC two-way simultaneous mode. Enumeration: 'disenable': 2, 'enable': 1.
                   hh3cdlswSdlcPortT1 1.3.6.1.4.1.25506.8.37.6.1.1.12 integer read-write
Time to wait for a reply to a frame.
                   hh3cdlswSdlcPortT2 1.3.6.1.4.1.25506.8.37.6.1.1.13 integer read-write
Time to wait for a reply used by secondary station.
           hh3cdlswSdlcLsTable 1.3.6.1.4.1.25506.8.37.6.2 no-access
The table defines the virtual MAC addresses for those SDLC link stations that participate in data link switching.
               hh3cdlswSdlcLsEntry 1.3.6.1.4.1.25506.8.37.6.2.1 no-access
                   hh3cdlswSdlcLsAddress 1.3.6.1.4.1.25506.8.37.6.2.1.1 integer read-only
Define SDLC address.
                   hh3cdlswSdlcLsLocalId 1.3.6.1.4.1.25506.8.37.6.2.1.2 integer read-write
The value is XID.
                   hh3cdlswSdlcLsRemoteMac 1.3.6.1.4.1.25506.8.37.6.2.1.3 macaddressnc read-write
The MAC address to which DLSw should attempt to connect this link station. If this information is not available, a length of zero for this object should be returned
                   hh3cdlswSdlcLsSsap 1.3.6.1.4.1.25506.8.37.6.2.1.4 integer read-write
Source SAP of partner.
                   hh3cdlswSdlcLsDsap 1.3.6.1.4.1.25506.8.37.6.2.1.5 integer read-write
Destination SAP of partner.
                   hh3cdlswSdlcLsStatus 1.3.6.1.4.1.25506.8.37.6.2.1.6 entrystatus read-write
This object is used by the manager to create or delete the row entry in the hh3cdlswSdlcLsTable following the EntryStatus textual convention.
       hh3cdlswLlc2 1.3.6.1.4.1.25506.8.37.7
           hh3cdlswLlc2PortTable 1.3.6.1.4.1.25506.8.37.7.1 no-access
The table defines parameters for the interfaces with the encapunation of Llc2.
               hh3cdlswLlc2PortEntry 1.3.6.1.4.1.25506.8.37.7.1.1 no-access
                   hh3cdlswLLC2PortAckDelayTime 1.3.6.1.4.1.25506.8.37.7.1.1.1 integer read-write
Max time allows I-frames incoming without replay ACK.
                   hh3cdlswLLC2PortAckMax 1.3.6.1.4.1.25506.8.37.7.1.1.2 integer read-write
Max number of I-frames received before ACK.
                   hh3cdlswLLC2PortLocalWnd 1.3.6.1.4.1.25506.8.37.7.1.1.3 integer read-write
Max number of I-frames to send before received ACK.
                   hh3cdlswLLC2PortModulus 1.3.6.1.4.1.25506.8.37.7.1.1.4 integer read-write
Modulus of LLC2. Enumeration: 'm128': 128, 'm8': 8.
                   hh3cdlswLLC2PortN2 1.3.6.1.4.1.25506.8.37.7.1.1.5 integer read-write
Retry times of operations.
                   hh3cdlswLLC2PortT1 1.3.6.1.4.1.25506.8.37.7.1.1.6 integer read-write
Waiting for ACK time after sent a I-frame.
                   hh3cdlswLLC2PortTbusyTime 1.3.6.1.4.1.25506.8.37.7.1.1.7 integer read-write
Waiting time while other LLC2 station is in busy state.
                   hh3cdlswLLC2PortTpfTime 1.3.6.1.4.1.25506.8.37.7.1.1.8 integer read-write
Waiting time after a P frame is sent.
                   hh3cdlswLLC2PortTrejTime 1.3.6.1.4.1.25506.8.37.7.1.1.9 integer read-write
Waiting time after a REJ frame is sent.
                   hh3cdlswLLC2PortTxqMax 1.3.6.1.4.1.25506.8.37.7.1.1.10 integer read-write
Queue for sending llc2 I-frames.
       hh3cdlswTraps 1.3.6.1.4.1.25506.8.37.8
           hh3cdlswTrapsV2 1.3.6.1.4.1.25506.8.37.8.0
               hh3cdlswTrapTConnPartnerReject 1.3.6.1.4.1.25506.8.37.8.0.1
This trap is sent each time a transport connection is rejected by a partner DLSw during Capabilities Exchanges. The emission of this trap is controlled by hh3cdlswTrapCntlCircuit.
               hh3cdlswTrapTConnChangeState 1.3.6.1.4.1.25506.8.37.8.0.2
This trap is sent each time a transport connection changes state. The emission of this trap is controlled by hh3cdlswTrapCntlTConn.
               hh3cdlswTrapCircuitChangeState 1.3.6.1.4.1.25506.8.37.8.0.3
This trap is sent each time a circuit change state. The emission of this trap is controlled by hh3cdlswTrapCntlCircuit.