FMS100-MIB: View SNMP OID List / Download MIB

VENDOR: 3COM


 Home MIB: FMS100-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 a3Com 1.3.6.1.4.1.43
       products 1.3.6.1.4.1.43.1
           hub 1.3.6.1.4.1.43.1.8
               linkBuilderFMS100 1.3.6.1.4.1.43.1.8.20
           cards 1.3.6.1.4.1.43.1.9
               linkBuilderFMS100_cards 1.3.6.1.4.1.43.1.9.10
                     linkBuilderFMS100_cards_12utp 1.3.6.1.4.1.43.1.9.10.1
       linkBuilderFMS100_mib 1.3.6.1.4.1.43.19
             hubEnviroObject 1.3.6.1.4.1.43.19.2
                 hubEnviroGroupTable 1.3.6.1.4.1.43.19.2.1 no-access
Table of Environment information about the group.
                     hubEnviroGroupEntry 1.3.6.1.4.1.43.19.2.1.1 no-access
An Entry in the table, containing information about a single group.
                         hubServiceId 1.3.6.1.4.1.43.19.2.1.1.1 integer read-only
This object identifies the repeater which this entry contains information. For FMS100, this is a constant 1.
                         hubGroupIndex 1.3.6.1.4.1.43.19.2.1.1.2 integer read-only
This object identifies the group within the repeater for which this entry contains information. This number is never greater than paRptrGroupCapacity.
                         hubHighTemp 1.3.6.1.4.1.43.19.2.1.1.3 integer read-only
This variable shows the current temperature status of the hub. If the variable changed from false to true, The enterprise-specific trap(a3comHighTemp) will be sent to the configured SNMP manager stations. Enumeration: 'false': 2, 'true': 1.
                         hubFanFailed 1.3.6.1.4.1.43.19.2.1.1.4 integer read-only
This variable shows the current Fan Fail status of the hub. If the variable changed from false to true, The enterprise-specific trap(a3comFanFailed) will be sent to the configured SNMP manager stations. Enumeration: 'false': 2, 'true': 1.
             pa100RptrSpecific 1.3.6.1.4.1.43.19.3
                 pa100RptrInfo 1.3.6.1.4.1.43.19.3.1
                     pa100RptrTable 1.3.6.1.4.1.43.19.3.1.1 no-access
Table of descriptive and STATUS information about the 100Mb Ethernet Hub
                         pa100RptrEntry 1.3.6.1.4.1.43.19.3.1.1.1 no-access
An entry in the table, containing information about the repeater.
                             pa100RptrServiceId 1.3.6.1.4.1.43.19.3.1.1.1.1 integer read-only
This object identifies the repeater which this entry contains information.
                             pa100RptrClass 1.3.6.1.4.1.43.19.3.1.1.1.2 integer read-only
The pa100RptrClass is the repeater class as defined in 802.3 standard. Class I: A type of repeater set specified such that in a maximum length segment topology, only one such repeater set may exist between any two DTEs within a single collision domain. Class II: A type of repeater set specified such that in a maximum length segment topology, only two such repeater set may exist between any two DTEs within a single collision domain. Enumeration: 'unknown': 3, 'classII': 2, 'classI': 1.
                             pa100RptrStackCardTypeInfo 1.3.6.1.4.1.43.19.3.1.1.1.3 octet string read-only
Supplies the information about the type of Cards in the repeater stack. There is one octet for each unit in the stack. Each octet can have the following values: 0 : undetected(power off or non-exist) 1 : repeater card 2 : management unit 3 : bridge/management card 4 : backup management(/bridge) card 5 : powered off 6 : unknown Value 0 indicates either the powered off card's cardindex is higher than all of the powered on cards or the card is non-existant. Value 5 indicates that the card is powered off and there are powered on card(s) with higher index number. Octet offset(started 0) N indicates N+1 th card information. I.e. The first octet indicates card 1's information.
                 pa100GroupInfo 1.3.6.1.4.1.43.19.3.2
                 pa100PortInfo 1.3.6.1.4.1.43.19.3.3
                     pa100PortTable 1.3.6.1.4.1.43.19.3.3.1 no-access
Table of descriptive and STATUS information about the ports that is specific to 100Mb Ethernet Hub
                         pa100PortEntry 1.3.6.1.4.1.43.19.3.3.1.1 no-access
An entry in the table, containing information about a single port.
                             pa100PortServiceId 1.3.6.1.4.1.43.19.3.3.1.1.1 integer read-only
This object identifies the repeater which this entry contains information.
                             pa100PortGroupIndex 1.3.6.1.4.1.43.19.3.3.1.1.2 integer read-only
This object identifies the group containing the port for which this entry contains information.
                             pa100PortIndex 1.3.6.1.4.1.43.19.3.3.1.1.3 integer read-only
This object identifies the port within the group for which this entry contains information. This value can never be greater than paRptrGroupPortCapacity for the associated group.
                             pa100PortIsolate 1.3.6.1.4.1.43.19.3.3.1.1.4 counter read-only
Increment counter by each time that the repeater port automatically isolates as a consequence of false carrier events. The conditions which cause a port to automatically isolate are as defined by the transition from the False Carrier state to the Link Unstable state of the carrier integrity state diagram.(802.3 std)
                             pa100PortSymbolErrorDuringPacket 1.3.6.1.4.1.43.19.3.3.1.1.5 counter read-only
A count of the number of times when valid length packet was received at the port and there was at least one occurrence of an invalid symbol. This can increment only once per valid carrier event. A collision presence at any port of the repeater containing port N, will not cause this attribute to increment.