Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 cadSpMgtMib 1.3.6.1.4.1.4998.1.1.15.4
The MIB module describes the C4 Upstream Spectrum Management
     cadSpMgtNotifications 1.3.6.1.4.1.4998.1.1.15.4.1
     cadSpMgtObjects 1.3.6.1.4.1.4998.1.1.15.4.2
         cadSpMgtGroup 1.3.6.1.4.1.4998.1.1.15.4.2.1
             cadSpMgtGroupTable 1.3.6.1.4.1.4998.1.1.15.4.2.1.1 no-access
Each entry in this table defines a C4 Upstream Spectrum Management group.
                 cadSpMgtGroupEntry 1.3.6.1.4.1.4998.1.1.15.4.2.1.1.1 no-access
A set of C4 Upstream Spectrum Management group information. Entries in the cadSpMgtGroupTable are created and deleted using the cadSpMgtGroupRowStatus object.
                     cadSpMgtGroupIndex 1.3.6.1.4.1.4998.1.1.15.4.2.1.1.1.1 integer32 no-access
The index used to identify the Upstream Spectrum Group.
                     cadSpMgtGroupSamplePeriod 1.3.6.1.4.1.4998.1.1.15.4.2.1.1.1.2 integer32 read-only
The time (in seconds) between samples used for the degradation and the improvement triggers.
                     cadSpMgtGroupHopPeriod 1.3.6.1.4.1.4998.1.1.15.4.2.1.1.1.3 integer32 read-only
The minimum period of time (in seconds) that must pass between successive state transitions.
                     cadSpMgtGroupCodeword 1.3.6.1.4.1.4998.1.1.15.4.2.1.1.1.4 integer32 read-only
The minimum number of codewords that must have been transmitted on the upstream channel before the degradation and improvement triggers are considered to be valid.
                     cadSpMgtGroupRetryPeriod 1.3.6.1.4.1.4998.1.1.15.4.2.1.1.1.5 integer32 read-only
This object specifies the minimum wait time (in seconds) before the retry is attempted. The retry-period timer controls how quickly the state machine is allowed to retry when transition failure occurred.
                     cadSpMgtGroupEnabled 1.3.6.1.4.1.4998.1.1.15.4.2.1.1.1.6 truthvalue read-only
This object allows for the optional enabling and disabling of a spectrum group.
                     cadSpMgtGroupRowStatus 1.3.6.1.4.1.4998.1.1.15.4.2.1.1.1.7 rowstatus read-only
The status of this conceptual row. To create a row in this table, set this object to createAndGo(4). Support of the values includes createAndGo(4) and destroy(6)
             cadSpMgtStateTable 1.3.6.1.4.1.4998.1.1.15.4.2.1.2 no-access
Each entry in this table defines a state used for C4 Upstream Spectrum Management.
                 cadSpMgtStateEntry 1.3.6.1.4.1.4998.1.1.15.4.2.1.2.1 no-access
A set of Upstream Spectrum Management state information. Entries in the cadSpMgtStateTable are created and deleted using the cadSpMgtStateRowStatus object.
                     cadSpMgtStateIndex 1.3.6.1.4.1.4998.1.1.15.4.2.1.2.1.1 integer32 no-access
The index used to identify the state in C4 Upstream Spectrum Management.
                     cadSpMgtStateFrequency 1.3.6.1.4.1.4998.1.1.15.4.2.1.2.1.2 integer32 read-only
The center of the frequency band for the upstream channel associated with this state.
                     cadSpMgtStateWidth 1.3.6.1.4.1.4998.1.1.15.4.2.1.2.1.3 integer32 read-only
The bandwidth for the upstream channel associated with this state.
                     cadSpMgtStateModulationProfile 1.3.6.1.4.1.4998.1.1.15.4.2.1.2.1.4 unsigned32 read-only
An entry identical to the docsIfModIndex in the docsIfCmtsModulationTable that describes the upstream channel associated with this state.
                     cadSpMgtStateRowStatus 1.3.6.1.4.1.4998.1.1.15.4.2.1.2.1.5 rowstatus read-only
The status of this conceptual row. To create a row in this table, set this object to createAndGo(4). Support of the values includes createAndGo(4) and destroy(6)
             cadSpMgtTriggerTable 1.3.6.1.4.1.4998.1.1.15.4.2.1.3 no-access
Each entry in this table defines a trigger for C4 Upstream Spectrum Management
                 cadSpMgtTriggerEntry 1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1 no-access
A set of Upstream Spectrum Management trigger information. Entries in the cadSpMgtTriggerTable are created and deleted using the cadSpMgtTriggerRowStatus object.
                     cadSpMgtTriggerIndex 1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.1 integer32 no-access
The trigger index used to identify the trigger for each state transition.
                     cadSpMgtTriggerType 1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.2 sptriggertype read-only
The trigger type.
                     cadSpMgtTriggerDay 1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.3 sptriggerday read-only
The trigger day is to specify the reoccurrence of the TOD trigger for a week. The trigger day has the following defined values: 0: Sunday 1: Monday 2: Tuesday 3: Wednesday 4: Thursday 5: Friday 6: Saturday 7: Everyday
                     cadSpMgtTriggerTOD 1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.4 sptimeofday read-only
Time of day to transition to next state, in HH:MM:SS format
                     cadSpMgtTriggerPeriod 1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.5 integer32 read-only
The amount of time that should be loaded into a timer, in seconds, once the state machine has transitioned into the associated current state. When the timer expires, the transition to next state defined in the state machine is executed. This value is an integer between 1 and 604,800 (which covers a period of a week). This object is applicable for trigger type of periodic(2)
                     cadSpMgtTriggerThres1 1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.6 unsigned32 read-only
This object is applicable for trigger type of degradation (3) and improvement (4). For degradation trigger, this is the maximum acceptable percentage of FEC errors (uncorrectable plus correctable). For improvement trigger, this is the minimum acceptable percentage of FEC errors (uncorrectable plus correctable)
                     cadSpMgtTriggerThres2 1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.7 unsigned32 read-only
This object is applicable for trigger type of degradation (3) and improvement (4). For degradation trigger, this is the maximum acceptable percentage of uncorrectable FEC errors. For improvement trigger, this is the minimum acceptable percentage of uncorrectable FEC errors.
                     cadSpMgtTriggerThres3 1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.8 tenthdb read-only
This object is applicable for trigger type of degradation (3) and improvement (4). For degradation trigger, this is the minimum acceptable Signal/Noise ratio (in dB). For improvement trigger, this is the maximum acceptable Signal/Noise ratio (in dB).
                     cadSpMgtTriggerRowStatus 1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.9 rowstatus read-only
The status of this conceptual row. To create a row in this table, set this object to createAndGo(4). Support of the values includes createAndGo(4) and destroy(6)
             cadSpMgtStateTransTable 1.3.6.1.4.1.4998.1.1.15.4.2.1.4 no-access
Each entry in this table defines the state machine in C4 Upstream Spectrum Management.
                 cadSpMgtStateTransEntry 1.3.6.1.4.1.4998.1.1.15.4.2.1.4.1 no-access
                     cadSpMgtTransNextState 1.3.6.1.4.1.4998.1.1.15.4.2.1.4.1.1 integer32 read-only
The index used to identify the next state to which the state machine may transition to as a result of this trigger.
                     cadSpMgtStateTransRowStatus 1.3.6.1.4.1.4998.1.1.15.4.2.1.4.1.2 rowstatus read-only
The status of this conceptual row. To create a row in this table, set this object to createAndGo(4). Support of the values includes createAndGo(4) and destroy(6)
             cadSpMgtHistoryTable 1.3.6.1.4.1.4998.1.1.15.4.2.1.5 no-access
Table of state transition history.
                 cadSpMgtHistoryEntry 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1 no-access
Entry of state transition history.
                     cadSpMgtHistoryUpChannelIfIndex 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.1 interfaceindex no-access
IfIndex of the upstream channel.
                     cadSpMgtHistoryTime 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.2 dateandtime no-access
The value of this object is the actual clock time when this entry was created.
                     cadSpMgtHistoryTriggerIndex 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.3 integer32 read-only
The trigger index used to identify the trigger for state transition. A value of 0 indicates a manual trigger.
                     cadSpMgtHistoryFromStateIndex 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.4 integer32 read-only
The index used to identify the current state.
                     cadSpMgtHistoryNextStateIndex 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.5 integer32 read-only
The index used to identify the next state to which the state machine may transition to.
                     cadSpMgtHistoryResultStateIndex 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.6 integer32 read-only
The index used to identify the result state to which the state machine has transitioned to. For a successful state transition request, the value of this object is the same as cadSpMgtHistoryNextState.
                     cadSpMgtHistorySNR 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.7 tenthdb read-only
This object is the measured Signal/Noise ratio (in dB) for the upstream channel. This object is applicable when the value in cadSpMgtHistoryTriggerIndex defines the trigger of type degradation or improvement.
                     cadSpMgtHistoryUFecError 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.8 unsigned32 read-only
This object is the measured percentage of uncorrectable FEC errors for the upstream channel. This object is applicable when the value in cadSpMgtHistoryTriggerIndex defines the trigger of type degradation or improvement.
                     cadSpMgtHistoryFecError 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.9 unsigned32 read-only
This object is the measured percentage of FEC errors (uncorrectable plus correctable) for the upstream channel. This object is applicable when the value in cadSpMgtHistoryTriggerIndex defines the trigger of type degradation or improvement.
                     cadSpMgtHistorySpareCardId 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.10 integer32 read-only
The cardId of the spare CAM. The value of 0 indicates the CAM is not spared at the time the request is received.
                     cadSpMgtHistoryText 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.11 displaystring read-only
This object provides a human-readable description of the entry, including all relevant context.
                     cadSpMgtHistoryGroupId 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.12 integer32 read-only
The Upstream Spectrum Group index associated with the upstream channel.
                     cadSpMgtHistoryStateChangeCount 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.13 unsigned16 read-only
Provides the count of state changes in the history entry. This object will always increase. It is 16 bits, once it is at 0xffff, the counter will roll over and start from beginning.
                     cadSpMgtHistorySysUpTime 1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.14 unsigned32 read-only
Provides the system up time in the history entry. This object will always increase.
             cadSpMgtUpChannelTable 1.3.6.1.4.1.4998.1.1.15.4.2.1.6 no-access
This table describes Upstream Frequency Agility attributes of attached upstream channels.
                 cadSpMgtUpChannelEntry 1.3.6.1.4.1.4998.1.1.15.4.2.1.6.1 no-access
The List of Upstream Frequency Agility attributes associated with an upstream channel.
                     cadSpMgtUpChannelCurrState 1.3.6.1.4.1.4998.1.1.15.4.2.1.6.1.1 integer32 read-only
The current state as a result of the upstream spectrum group state transition. This object is only applicable if upstream spectrum management is enabled for this upstream channel.
                     cadSpMgtUpChannelStateTransTime 1.3.6.1.4.1.4998.1.1.15.4.2.1.6.1.2 dateandtime read-only
The value of this object is the actual clock time when the current state information in cadIfUpChannelSpGroupCurrState is most recently updated.
         cadSpMgtRequests 1.3.6.1.4.1.4998.1.1.15.4.2.2
             cadSpMgtRequestUpChannelIfIndex 1.3.6.1.4.1.4998.1.1.15.4.2.2.1 interfaceindex read-write
IfIndex of the upstream channel.
             cadSpMgtRequestTriggerIndex 1.3.6.1.4.1.4998.1.1.15.4.2.2.2 integer32 read-write
The trigger index used to identify the trigger. A value of 0 indicates no trigger is attempted.
             cadSpMgtRequestNextState 1.3.6.1.4.1.4998.1.1.15.4.2.2.3 integer32 read-write
The index used to identify the next state to which the state machine may transition to.
             cadSpMgtRequestSNR 1.3.6.1.4.1.4998.1.1.15.4.2.2.4 tenthdb read-write
This object is the measured Signal/Noise ratio (in dB) for the upstream channel. This object is applicable when the value in cadSpMgtRequestTriggerIndex defines the trigger of type degradation or improvement.
             cadSpMgtRequestUFecError 1.3.6.1.4.1.4998.1.1.15.4.2.2.5 unsigned32 read-write
This object is the measured percentage of uncorrectable FEC errors for the upstream channel. This object is applicable when the value in cadSpMgtRequestTriggerIndex defines the trigger of type degradation or improvement.
             cadSpMgtRequestFecError 1.3.6.1.4.1.4998.1.1.15.4.2.2.6 unsigned32 read-write
This object is the measured percentage of FEC errors (uncorrectable plus correctable) for the upstream channel. This object is applicable when the value in cadSpMgtRequestTriggerIndex defines the trigger of type degradation or improvement.
             cadSpMgtRequestCommit 1.3.6.1.4.1.4998.1.1.15.4.2.2.7 truthvalue read-write
The command to execute the request when set to true(1). The following are reasons for rejecting an SNMP SET to this object: - An operation is commited for a non-existing upstream channel ID or the corresponding ifOperStatus is down(2). - An operation is committed but cadSpMgtRequestNextState is not an existing state index in cadSpMgtStateEntry. - An operation is committed but the value in cadSpMgtRequestTriggerIndex is non-zero and not an existing trigger index in cadSpMgtTriggerEntry. Reading this object always returns false(2).
     cadSpMgtConformance 1.3.6.1.4.1.4998.1.1.15.4.3