AT-PLUGGABLE-DIAGNOSTICS-MIB: View SNMP OID List / Download MIB

VENDOR: ALLIED TELESIS


 Home MIB: AT-PLUGGABLE-DIAGNOSTICS-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 atPluggableDiag 1.3.6.1.4.1.207.8.4.4.3.28
The AT Pluggbale Diagnostics MIB contains objects to retrieve the standard diagnostic information from installed SFP modules.
       atPluggableDiagTable 1.3.6.1.4.1.207.8.4.4.3.28.1
           atPluggableDiagTempTable 1.3.6.1.4.1.207.8.4.4.3.28.1.1 no-access
A table of information regarding the various temperature parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.
               atPluggableDiagTempEntry 1.3.6.1.4.1.207.8.4.4.3.28.1.1.1 no-access
The information about various temperature parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, current warning, higher and lower warning threshold.
                   atPluggableDiagTempIfIndex 1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.1 interfaceindex no-access
The ifindex of the pluggable.
                   atPluggableDiagTempChannel 1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.2 integer32 no-access
The channel number of the pluggable.
                   atPluggableDiagTempStatusReading 1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.3 integer32 read-only
The current temperature status reading.
                   atPluggableDiagTempCurrentAlarm 1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.4 octet string read-only
The current temperature alarm reading.
                   atPluggableDiagTempAlarmMax 1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.5 integer32 read-only
The maximum temperature alarm threshold value.
                   atPluggableDiagTempAlarmMin 1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.6 integer32 read-only
The minimum temperature alarm threshold value.
                   atPluggableDiagTempCurrentWarning 1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.7 octet string read-only
The current temperature warnings.
                   atPluggableDiagTempWarningMax 1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.8 integer32 read-only
The maximum temperature warning threshold value.
                   atPluggableDiagTempWarningMin 1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.9 integer32 read-only
The minimum temperature warning threshold value.
           atPluggableDiagVccTable 1.3.6.1.4.1.207.8.4.4.3.28.1.2 no-access
A table of information regarding the various Voltage (Vcc) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.
               atPluggableDiagVccEntry 1.3.6.1.4.1.207.8.4.4.3.28.1.2.1 no-access
The information about various Voltage (Vcc) parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, current warning, higher and lower warning threshold.
                   atPluggableDiagVccIfIndex 1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.1 interfaceindex no-access
The ifindex of the pluggable.
                   atPluggableDiagVccChannel 1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.2 integer32 no-access
The channel number of the pluggable.
                   atPluggableDiagVccStatusReading 1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.3 integer32 read-only
The current Voltage (Vcc) status reading.
                   atPluggableDiagVccCurrentAlarm 1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.4 octet string read-only
The current Voltage (Vcc) alarm reading.
                   atPluggableDiagVccAlarmMax 1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.5 integer32 read-only
The maximum Voltage (Vcc) alarm threshold value.
                   atPluggableDiagVccAlarmMin 1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.6 integer32 read-only
The minimum Voltage (Vcc) alarm threshold value.
                   atPluggableDiagVccCurrentWarning 1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.7 octet string read-only
The current Voltage (Vcc) warnings.
                   atPluggableDiagVccWarningMax 1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.8 integer32 read-only
The maximum Voltage (Vcc) warning threshold value.
                   atPluggableDiagVccWarningMin 1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.9 integer32 read-only
The minimum Voltage (Vcc) warning threshold value.
           atPluggableDiagTxBiasTable 1.3.6.1.4.1.207.8.4.4.3.28.1.3 no-access
A table of information regarding the various Tx Bias Current (mA) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.
               atPluggableDiagTxBiasEntry 1.3.6.1.4.1.207.8.4.4.3.28.1.3.1 no-access
The information about various Tx Bias Current (mA) parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, current warning, higher and lower warning threshold.
                   atPluggableDiagTxBiasIfIndex 1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.1 interfaceindex no-access
The ifindex of the pluggable.
                   atPluggableDiagTxBiasChannel 1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.2 integer32 no-access
The channel number of the pluggable.
                   atPluggableDiagTxBiasStatusReading 1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.3 integer32 read-only
The current Tx Bias (mA) status reading.
                   atPluggableDiagTxBiasCurrentAlarm 1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.4 octet string read-only
The current Tx Bias (mA) alarm reading.
                   atPluggableDiagTxBiasAlarmMax 1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.5 integer32 read-only
The maximum Tx Bias (mA) alarm threshold value.
                   atPluggableDiagTxBiasAlarmMin 1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.6 integer32 read-only
The minimum Tx Bias (mA) alarm threshold value.
                   atPluggableDiagTxBiasCurrentWarning 1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.7 octet string read-only
The current Tx Bias (mA) warnings.
                   atPluggableDiagTxBiasWarningMax 1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.8 integer32 read-only
The maximum Tx Bias (mA) warning threshold value.
                   atPluggableDiagTxBiasWarningMin 1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.9 integer32 read-only
The minimum Tx Bias (mA) warning threshold value.
           atPluggableDiagTxPowerTable 1.3.6.1.4.1.207.8.4.4.3.28.1.4 no-access
A table of information regarding the various Tx Power (mW) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.
               atPluggableDiagTxPowerEntry 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1 no-access
The information about various Tx Power (mW) parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, current warning, higher and lower warning threshold.
                   atPluggableDiagTxPowerIfIndex 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.1 interfaceindex no-access
The ifindex of the pluggable.
                   atPluggableDiagTxPowerChannel 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.2 integer32 no-access
The channel number of the pluggable.
                   atPluggableDiagTxPowerStatusReading 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.3 integer32 read-only
The current Tx Power (mW) status reading.
                   atPluggableDiagTxPowerCurrentAlarm 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.4 octet string read-only
The current Tx Power (mW) alarm reading.
                   atPluggableDiagTxPowerAlarmMax 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.5 integer32 read-only
The maximum Tx Power (mW) alarm threshold value.
                   atPluggableDiagTxPowerAlarmMin 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.6 integer32 read-only
The minimum Tx Power (mW) alarm threshold value.
                   atPluggableDiagTxPowerCurrentWarning 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.7 octet string read-only
The current Tx Power (mW) warnings.
                   atPluggableDiagTxPowerWarningMax 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.8 integer32 read-only
The maximum Tx Power (mW) warning threshold value.
                   atPluggableDiagTxPowerWarningMin 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.9 integer32 read-only
The minimum Tx Power (mW) warning threshold value.
           atPluggableDiagRxPowerTable 1.3.6.1.4.1.207.8.4.4.3.28.1.5 no-access
A table of information regarding the various Rx Power (mW) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.
               atPluggableDiagRxPowerEntry 1.3.6.1.4.1.207.8.4.4.3.28.1.5.1 no-access
The information about various Rx Power (mW) parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, current warning, higher and lower warning threshold.
                   atPluggableDiagRxPowerIfIndex 1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.1 interfaceindex no-access
The ifindex of the pluggable.
                   atPluggableDiagRxPowerChannel 1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.2 integer32 no-access
The channel number of the pluggable.
                   atPluggableDiagRxPowerStatusReading 1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.3 integer32 read-only
The current Rx Power (mW) status reading.
                   atPluggableDiagRxPowerCurrentAlarm 1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.4 octet string read-only
The current Rx Power (mW) alarm reading.
                   atPluggableDiagRxPowerAlarmMax 1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.5 integer32 read-only
The maximum Rx Power (mW) alarm threshold value.
                   atPluggableDiagRxPowerAlarmMin 1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.6 integer32 read-only
The minimum Rx Power (mW) alarm threshold value.
                   atPluggableDiagRxPowerCurrentWarning 1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.7 octet string read-only
The current Rx Power (mW) warnings.
                   atPluggableDiagRxPowerWarningMax 1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.8 integer32 read-only
The maximum Rx Power (mW) warning threshold value.
                   atPluggableDiagRxPowerWarningMin 1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.9 integer32 read-only
The minimum Rx Power (mW) warning threshold value.
           atPluggableDiagRxLosTable 1.3.6.1.4.1.207.8.4.4.3.28.1.6 no-access
A table of information regarding the Rx Loss of Singal (Los) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.
               atPluggableDiagRxLosEntry 1.3.6.1.4.1.207.8.4.4.3.28.1.6.1 no-access
The information about various Rx Loss of Singal (Los) parameters of pluggables such as current status reading.
                   atPluggableDiagRxLosIfIndex 1.3.6.1.4.1.207.8.4.4.3.28.1.6.1.1 interfaceindex no-access
The ifindex of the pluggable.
                   atPluggableDiagRxLosChannel 1.3.6.1.4.1.207.8.4.4.3.28.1.6.1.2 integer32 no-access
The channel number of the pluggable.
                   atPluggableDiagRxLosStatusReading 1.3.6.1.4.1.207.8.4.4.3.28.1.6.1.3 octet string read-only
The current Rx Los status reading.