ASCEND-MIBLINEDIAG-MIB: View SNMP OID List / Download MIB

VENDOR: ASCEND COMMUNICATIONS INC.


 Home MIB: ASCEND-MIBLINEDIAG-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 mibmibProfLineDiag 1.3.6.1.4.1.529.23.145
         mibmibProfLineDiagTable 1.3.6.1.4.1.529.23.145.1 no-access
A list of mibmibProfLineDiag profile entries.
             mibmibProfLineDiagEntry 1.3.6.1.4.1.529.23.145.1.1 no-access
A mibmibProfLineDiag entry containing objects that maps to the parameters of mibmibProfLineDiag profile.
                 mibProfLineDiag_Shelf_o 1.3.6.1.4.1.529.23.145.1.1.1 integer read-only
                 mibProfLineDiag_Slot_o 1.3.6.1.4.1.529.23.145.1.1.2 integer read-only
                 mibProfLineDiag_Item_o 1.3.6.1.4.1.529.23.145.1.1.3 integer read-only
                 mibProfLineDiag_PhysicalAddress_Shelf 1.3.6.1.4.1.529.23.145.1.1.4 integer read-write
The number of the shelf that the addressed physical device resides on. Enumeration: 'anyShelf': 1, 'shelf2': 3, 'shelf3': 4, 'shelf1': 2, 'shelf6': 7, 'shelf7': 8, 'shelf4': 5, 'shelf5': 6, 'shelf8': 9, 'shelf9': 10.
                 mibProfLineDiag_PhysicalAddress_Slot 1.3.6.1.4.1.529.23.145.1.1.5 integer read-write
The number of the slot that the addressed physical device resides on. Enumeration: 'aLim': 55, 'bLim': 56, 'trunkModule2': 46, 'slot36': 37, 'firstControlModule': 53, 'trunkModule1': 45, 'rightController': 50, 'slot28': 29, 'slot29': 30, 'slot24': 25, 'slot25': 26, 'slot26': 27, 'slot27': 28, 'slot20': 21, 'slot21': 22, 'slot22': 23, 'slot23': 24, 'slotPrimary': 59, 'cLim': 57, 'slot40': 41, 'secondControlModule': 54, 'leftController': 49, 'slot39': 40, 'controlModule': 51, 'slot9': 10, 'slot8': 9, 'controller': 42, 'slot38': 39, 'slot1': 2, 'slot3': 4, 'slot2': 3, 'slot5': 6, 'slot4': 5, 'slot7': 8, 'slot6': 7, 'slot11': 12, 'slot10': 11, 'slot13': 14, 'slot12': 13, 'slot15': 16, 'slot14': 15, 'slot17': 18, 'slot16': 17, 'slot19': 20, 'slot18': 19, 'slot31': 32, 'slot30': 31, 'slot37': 38, 'anySlot': 1, 'slot35': 36, 'slot34': 35, 'slot33': 34, 'dLim': 58, 'slot32': 33.
                 mibProfLineDiag_PhysicalAddress_ItemNumber 1.3.6.1.4.1.529.23.145.1.1.6 integer read-write
A number that specifies an addressable entity within the context of shelf and slot.
                 mibProfLineDiag_BertTimer 1.3.6.1.4.1.529.23.145.1.1.7 integer read-write
When this time period expires the BER Test is stopped. Enumeration: 'n-10Minutes': 600001, 'n-3Minutes': 180001, 'n-2Minutes': 120001, 'n-5Minutes': 300001, 'n-4Minutes': 240001, 'n-20Minutes': 1200001, 'n-30Minutes': 1800001, 'n-15Minutes': 900001, 'n-1Minute': 60001.
                 mibProfLineDiag_BertEnable 1.3.6.1.4.1.529.23.145.1.1.8 integer read-write
To enable the BER test set this parameter to yes. Enumeration: 'yes': 2, 'no': 1.
                 mibProfLineDiag_IdtEnable 1.3.6.1.4.1.529.23.145.1.1.9 integer read-write
To enable the IDT test set this parameter to yes. Enumeration: 'yes': 2, 'no': 1.
                 mibProfLineDiag_IdtNumOfMsg 1.3.6.1.4.1.529.23.145.1.1.10 integer read-write
Number of Messages to be sent for the IDT test.
                 mibProfLineDiag_Action_o 1.3.6.1.4.1.529.23.145.1.1.11 integer read-write
Enumeration: 'deleteProfile': 3, 'createProfile': 2, 'noAction': 1.