Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 acAnalog 1.3.6.1.4.1.5003.9.10.8
     acAnalogConfiguration 1.3.6.1.4.1.5003.9.10.8.1
         acAnalogConfig 1.3.6.1.4.1.5003.9.10.8.1.1
             acAnalogMisc 1.3.6.1.4.1.5003.9.10.8.1.1.1
                 acAnalogMiscCurrentDisconnectDuration 1.3.6.1.4.1.5003.9.10.8.1.1.1.1 unsigned32 read-write
Defines the current-disconnect duration (in msec). This value is used in generation and detection. Access: Offline. AC INI-Param: CurrentDisconnectDuration
                 acAnalogMiscFlashHookPeriod 1.3.6.1.4.1.5003.9.10.8.1.1.1.2 unsigned32 read-write
Defines the flashhook period (in msec) for both analog and IP sides. For the analog side it defines: - The maximal hook-flash detection period (for FXS gateways). A longer signal is considered offhook / onhook event. - The hook-flash generation period (for FXO gateways). For the IP side it defines the flash-hook period that is reported to IP. The valid range is 25 to 1500. The default value is 700 msec. Note: For FXO gateways, a constant of 90 msec must be added to the required hook-flash period. For example, to generate a 450 msec hook-flash, set FlashHookPeriod to 540. . Access: Instant. AC INI-Param: FLASHHOOKPERIOD
                 acAnalogMiscGroundKeyDetection 1.3.6.1.4.1.5003.9.10.8.1.1.1.3 integer read-write
Enables/disables the analog ground key detection. 0 = Disable 1= Enable. Access: Offline. AC INI-Param: GroundKeyDetection Enumeration: 'enable': 1, 'disable': 0.
             acAuxiliaryFiles 1.3.6.1.4.1.5003.9.10.8.1.1.2
                 acAuxiliaryFilesFxsCoefficients 1.3.6.1.4.1.5003.9.10.8.1.1.2.1 snmpadminstring read-only
Defines the FXS coefficient file name. AC INI-Param: FXSCOEFFILENAME
                 acAuxiliaryFilesFxoCoefficients 1.3.6.1.4.1.5003.9.10.8.1.1.2.2 snmpadminstring read-only
Defines the FXO coefficient filename. Max. 47 characters. AC INI-Param: FXOCOEFFILENAME
         acAnalogFxoConfig 1.3.6.1.4.1.5003.9.10.8.1.2
             acAnalogFxo 1.3.6.1.4.1.5003.9.10.8.1.2.1
                 acAnalogFxoFarEndDisconnectType 1.3.6.1.4.1.5003.9.10.8.1.2.1.1 unsigned32 read-write
This parameter sets the source for the acEV_FAR_END_DISCONNECTED event (or for the relevant control protocol event). It is a bit field parameter, hence (for example) if both CPT and current disconnect are required, the parameter should be set to 5. FarDisconnect contributor: 1 = CPT 2 = PolarityReversal 4 = CurrentDisconnect 8 = Silence. Access: Offline. AC INI-Param: FARENDDISCONNECTTYPE
                 acAnalogFxoCountryCoefficients 1.3.6.1.4.1.5003.9.10.8.1.2.1.2 integer read-write
Allows the user to modify the line characteristic (AC and DC) according to country. Access: Offline. AC INI-Param: CountryCoefficients Enumeration: 'europe': 66, 'unitedStates': 70.
                 acAnalogFxoDCRemover 1.3.6.1.4.1.5003.9.10.8.1.2.1.3 integer read-write
Determines whether to enable the analog DC remover in the DAA. One of the following values: 0 = DC remover is disabled 1 = DC remover is enabled. Access: Offline. AC INI-Param: EnableAnalogDCRemover Enumeration: 'enable': 1, 'disable': 0.
                 acAnalogFxoFarEndDisconnectToneTable 1.3.6.1.4.1.5003.9.10.8.1.2.1.21 no-access
                       acAnalogFxoFarEndDisconnectToneEntry 1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1 no-access
                           acAnalogFxoFarEndDisconnectToneRowStatus 1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.1 unsigned32 read-write
Far End Disconnect table row-status. AC INI-Param: N/A
                           acAnalogFxoFarEndDisconnectToneAction 1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.2 unsigned32 read-write
Far End Disconnect table action. AC INI-Param: N/A
                           acAnalogFxoFarEndDisconnectToneActionResult 1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.3 unsigned32 read-only
Far End Disconnect table result. AC INI-Param: N/A
                           acAnalogFxoFarEndDisconnectToneIndex 1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.4 unsigned32 read-only
Index for table use. AC INI-Param: N/A
                           acAnalogFxoFarEndDisconnectToneType 1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.5 integer read-write
Defines which CPT types are detected as far-end disconnect. The CPT type is based on the acTCallProgressToneType enum. This is valid when FarEndDisconnectType allows CPT detection. Range = An array of up to 4 tone types. Access: Offline. AC INI-Param: DISCONNECTTONETYPE Enumeration: 'acReorderTone': 7, 'acOnHoldTone': 23, 'acPayphoneRecognitionTone': 38, 'acPresConfNotifyType': 42, 'acCallProgressCo2Tone': 11, 'acCallTransferDialTone': 24, 'acTT904ContinuityTone': 214, 'acTrunkTestingTestProgressTone': 203, 'acOldMilliwattTone': 12, 'acComfortTone': 18, 'acPrecRTType': 44, 'acNewMilliwattTone': 13, 'acPlayRecordBeepTone': 202, 'acConfTimeLimitTone': 37, 'acGeneralTrunkTestingTone1': 207, 'acSpecialInfoTone': 5, 'acNullTone': 0, 'acNAKTone': 19, 'acConfExitTone': 34, 'acConfEnterTone': 33, 'acSTUModemSecondTone': 299, 'acWaitingTone4': 32, 'acGeneralTrunkTestingTone3': 209, 'acWaitingTone1': 17, 'acWaitingTone3': 31, 'acRingingTone': 2, 'acAlertingTone': 28, 'acCallForwardTone': 25, 'acSTUModemFirstTone': 298, 'acTrunkTestingTestTone': 204, 'acConfirmationTone': 8, 'acSpecialConditionTone': 21, 'acCNGFaxTone': 40, 'acCallProgressCo1Tone': 10, 'acStutterOffHookWarningTone': 16, 'acCongestionTone': 4, 'acCarrierDialTone': 216, 'acWaitingTone': 9, 'acVacantNumberTone': 20, 'acWarningTone': 6, 'acR15reqOfANItone': 45, 'acBusyTone': 3, 'acMessageWaitingIndicator': 14, 'acStutterDialTone': 15, 'acCreditCardServiceTone': 26, 'acGeneralTrunkTestingTone2': 208, 'acPrecConfNotifyType': 41, 'acTTMilliwattLossMeasureTone': 215, 'acSpecialInfoToneFirst': 210, 'acDialTone': 1, 'acSpecialRecallDialTone': 27, 'acNetworkCongestionTone': 29, 'acCo2Tone': 201, 'acCarrierAnswerTone': 217, 'acWaitingTone2': 30, 'acCallerWaitingTone': 39, 'acPrecPreemptType': 43, 'acFSKTrunkTestingTone': 206, 'acCarrierChargingTone': 218, 'acConfLockTone': 35, 'acSpecialInfoToneThird': 212, 'acDialTone2': 22, 'acCo1Tone': 200, 'acSpecialInfoToneSecond': 211, 'acLongDistanceIndicatorTone': 219, 'acTrunkTestingGuardTone': 205, 'acTTYTone': 213, 'acConfUnlockTone': 36.
         acAnalogFxsConfig 1.3.6.1.4.1.5003.9.10.8.1.3
             acAnalogFxs 1.3.6.1.4.1.5003.9.10.8.1.3.1
                 acAnalogFxsPolarityReversalType 1.3.6.1.4.1.5003.9.10.8.1.3.1.1 integer read-write
Sets the type of the polarity reversal signal used for the network far-end answer and disconnect indications. Smooth reversal prevents negative effects as non-required ringing. 0 = Soft reverse polarity 1 = Hard reverse polarity. Access: Offline. AC INI-Param: POLARITYREVERSALTYPE Enumeration: 'hard': 1, 'soft': 0.
                 acAnalogFxsMeteringType 1.3.6.1.4.1.5003.9.10.8.1.3.1.2 integer read-write
Sets the metering method for charging pulses. 0 = 12 kHz sinusoidal bursts 1 = 16 kHz sinusoidal bursts 2 = Polarity Reversal pulses. Access: Offline. AC INI-Param: METERINGTYPE Enumeration: 'mt12kHz': 0, 'mt16kHz': 1, 'mtPolarityReversal': 2.
                 acAnalogFxsLifeLineType 1.3.6.1.4.1.5003.9.10.8.1.3.1.3 integer read-write
Defines the Lifeline phone type. The Lifeline phone is available (for FXS only) on port 4 in MP-104 and MP-108, on port 2 in MP-102, on ports 1-4 in the MP-118, and on port 2 of each analog module in the Mediant 1000. 0 = activate Lifeline phone on power down 1 = activate Lifeline phone on power down or on detection of LAN disconnect 2 = activate Lifeline phone on power down, or on detection of LAN disconnect, or on loss of ping. Access: Offline. AC INI-Param: LIFELINETYPE Enumeration: 'acLifeLineType-Hardware-Only': 0, 'acLifeLineTypeHardware-And-Link-Detection': 1, 'acLifeLineType-Hardware-And-Link-And-Network-Detection': 2.
                 acAnalogFxsMinFlashHookTime 1.3.6.1.4.1.5003.9.10.8.1.3.1.4 unsigned32 read-write
Sets the minimal time (in msec) for detection of a flash-hook event (for FXS only). The valid range is 25 to 300. The default value is 300 msec. Detection is guaranteed for flash hook periods of at least 60 msec (when setting the minimal time to 25). Flash-hook signals that last a shorter period of time are ignored. Note: It is recommended to reduce the detection time by 50 msec from the desired value (e.g. if you set the value as 200 msec, then enter 150 msec, i.e. 200 minus 50). . Access: Offline. AC INI-Param: MINFLASHHOOKTIME
                 acAnalogFxsCallerIDTimingMode 1.3.6.1.4.1.5003.9.10.8.1.3.1.5 integer read-write
Defines the Analog CallerID Timing Mode. 0 = CallerID transferred between first and second rings 1 = CallerID transferred on valid Off ring. Access: Offline. AC INI-Param: ANALOGCALLERIDTIMINGMODE Enumeration: 'enable': 1, 'disable': 0.
                 acAnalogFxsBellcoreCallerIDTypeOneSubStandard 1.3.6.1.4.1.5003.9.10.8.1.3.1.6 integer read-write
Selects the sub-standard of the Bellcore Caller ID type. 0 = Between_Rings 1 = Not_Ring_Related 2 = Before_Ring_RP_AS. Access: Offline. AC INI-Param: BellcoreCallerIDTypeOneSubStandard Enumeration: 'bellcore-Between-Rings': 0, 'bellcore-Not-Ring-Related': 1, 'bellcore-Before-Ring-RP-AS': 2.
                 acAnalogFxsETSICallerIDTypeOneSubStandard 1.3.6.1.4.1.5003.9.10.8.1.3.1.7 integer read-write
Selects the number denoting the ETSI CallerID Type 1 sub-standard. Either: 0 = ETSI_Between_Rings 1 = ETSI_Before_Ring_DT_AS 2 = ETSI_Before_Ring_RP_AS 3 = ETSI_Before_Ring_LR_DT_AS 4 = ETSI_Not_Ring_Related_DT_AS 5 = ETSI_Not_Ring_Related_RP_AS 6 = ETSI_Not_Ring_Related_LR_DT_AS. Access: Offline. AC INI-Param: ETSICallerIDTypeOneSubStandard Enumeration: 'eTSI-Before-Ring-DT-AS': 1, 'eTSI-Not-Ring-Related-LR-DT-AS': 6, 'eTSI-Before-Ring-LR-DT-AS': 3, 'eTSI-Between-Rings': 0, 'eTSI-Not-Ring-Related-DT-AS': 4, 'eTSI-Before-Ring-RP-AS': 2, 'eTSI-Not-Ring-Related-RP-AS': 5.
                 acAnalogFxsETSIVMWITypeOneStandard 1.3.6.1.4.1.5003.9.10.8.1.3.1.8 integer read-write
Selects the number denoting the ETSI VMWI Type 1 Standard. Choose: 0 = ETSI_VMWI_Between_Rings 1 = ETSI_VMWI_Before_Ring_DT_AS 2 = ETSI_VMWI_Before_Ring_RP_AS 3 = ETSI_VMWI_Before_Ring_LR_DT_AS 4 = ETSI_VMWI_Not_Ring_Related_DT_AS 5 = ETSI_VMWI_Not_Ring_Related_RP_AS 6 = ETSI_VMWI_Not_Ring_Related_LR_DT_AS. Access: Offline. AC INI-Param: ETSIVMWITypeOneStandard Enumeration: 'eTSI-VMWI-Between-Rings': 0, 'eTSI-VMWI-Not-Ring-Related-DT-AS': 4, 'eTSI-VMWI-Before-Ring-RP-AS': 2, 'eTSI-VMWI-Not-Ring-Related-RP-AS': 5, 'eTSI-VMWI-Not-Ring-Related-LR-DT-AS': 6, 'eTSI-VMWI-Before-Ring-LR-DT-AS': 3, 'eTSI-VMWI-Before-Ring-DT-AS': 1.
                 acAnalogFxsBellcoreVMWITypeOneStandard 1.3.6.1.4.1.5003.9.10.8.1.3.1.9 integer read-write
Use this parameter to select the Bellcore VMWI standard. 0 - Between_Rings 1 - Not_Ring_Related. Access: Offline. AC INI-Param: BellcoreVMWITypeOneStandard Enumeration: 'bellcore-VMWI-Not-Ring-Related': 1, 'bellcore-VMWI-Between-Rings': 0.
                 acAnalogFxsDisableAutoCalibration 1.3.6.1.4.1.5003.9.10.8.1.3.1.10 unsigned32 read-write
Determines whether to enable the analog Autocalibration in the DAA. One of the following values: 0 = Auto calibration is enabled 1 = Auto calibration is disabled. Access: Offline. AC INI-Param: DisableAnalogAutoCalibration
                 acAnalogFxsExternalLifeLinePorts 1.3.6.1.4.1.5003.9.10.8.1.3.1.11 unsigned32 read-write
Set the amount of FXS ports which will be connected to an external life line and will be disabled (max value is half of the FXS ports). Access: Offline. AC INI-Param: ExternalLifeLinePorts
                 acAnalogFxsCountryCoefficients 1.3.6.1.4.1.5003.9.10.8.1.3.1.12 integer read-write
Allows the user to modify the line characteristic (AC and DC) according to country. Access: Offline. AC INI-Param: FXSCountryCoefficients Enumeration: 'europe': 66, 'unitedStates': 70.
                 acAnalogFxsTTXVoltageLevel 1.3.6.1.4.1.5003.9.10.8.1.3.1.13 integer read-write
Sets the TTX pulses voltage level. 0 = 0Vrms sinusoidal bursts 1 = 0.5Vrms sinusoidal bursts 2 = 1Vrms sinusoidal bursts -1 = notAvailable. Access: Offline. AC INI-Param: AnalogTTXVoltageLevel Enumeration: 'notAvailable': -1, 'ttxVoltageLevel05': 1, 'ttxVoltageLevel0V': 0, 'ttxVoltageLevel1V': 2.
     acAnalogStatus 1.3.6.1.4.1.5003.9.10.8.2
         acAnalogStatusMisc 1.3.6.1.4.1.5003.9.10.8.2.1
             acAnalogStatusMiscFxsOrFxo 1.3.6.1.4.1.5003.9.10.8.2.1.1 integer read-only
Board is Fxs Or Fxo (For all devices except MP118). For MP118 - see acAnalogFxsFxoType for a line specific status. AC INI-Param: N/A Enumeration: 'fXO': 0, 'fXS': 1.
             acAnalogStatusMiscBoardTemperature 1.3.6.1.4.1.5003.9.10.8.2.1.2 unsigned32 read-only
Temperature of the board in degrees Celsius, should not go higher then 60!. AC INI-Param: N/A
             acAnalogStatusMiscAnalogChannelsCount 1.3.6.1.4.1.5003.9.10.8.2.1.3 unsigned32 read-only
Number of the Analog channels in the board. AC INI-Param: N/A
         acAnalogFxsFxo 1.3.6.1.4.1.5003.9.10.8.2.20
               acAnalogFxsFxoTable 1.3.6.1.4.1.5003.9.10.8.2.20.1 no-access
                   acAnalogFxsFxoEntry 1.3.6.1.4.1.5003.9.10.8.2.20.1.1 no-access
                       acAnalogFxsFxoIndex 1.3.6.1.4.1.5003.9.10.8.2.20.1.1.1 unsigned32 no-access
Index for table use. AC INI-Param: N/A
                       acAnalogFxsFxoType 1.3.6.1.4.1.5003.9.10.8.2.20.1.1.2 integer read-only
Line is Fxs Or Fxo. AC INI-Param: N/A Enumeration: 'fXO': 0, 'fXS': 1.
                       acAnalogFxsFxoChipRevNum 1.3.6.1.4.1.5003.9.10.8.2.20.1.1.3 unsigned32 read-only
Fxs/Fxo's Chip revision number. AC INI-Param: N/A
                       acAnalogFxsFxoHookState 1.3.6.1.4.1.5003.9.10.8.2.20.1.1.4 integer read-only
The hook state of the analog line. AC INI-Param: N/A Enumeration: 'offHookState': 2, 'onHookState': 1.
         acAnalogLegs 1.3.6.1.4.1.5003.9.10.8.2.21
               acAnalogLegsTable 1.3.6.1.4.1.5003.9.10.8.2.21.1 no-access
                   acAnalogLegsEntry 1.3.6.1.4.1.5003.9.10.8.2.21.1.1 no-access
                       acAnalogLegsLegIndex 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.1 unsigned32 no-access
Decribes The Digital EndPoint In A Call. AC INI-Param: N/A
                       acAnalogLegsCallIndex 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.2 unsigned32 read-only
Decribes The Call which The Rtp EndPoint Participant In It. AC INI-Param: N/A
                       acAnalogLegsAnalogType 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.3 integer read-only
Describs whether the board is FXS or FXO. AC INI-Param: N/A Enumeration: 'fxo': 2, 'fxs': 1.
                       acAnalogLegsEchoCanceller 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.4 integer read-only
Enables or Disables the Echo Canceller. AC INI-Param: N/A Enumeration: 'enable': 1, 'disable': 0.
                       acAnalogLegsHighPassFilter 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.5 integer read-only
Enables or Disables theHigh Pass Filter. AC INI-Param: N/A Enumeration: 'enable': 1, 'disable': 0.
                       acAnalogLegsDTMFDetection 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.6 integer read-only
Enables or Disables the DTMF Detection. AC INI-Param: N/A Enumeration: 'enable': 1, 'disable': 0.
                       acAnalogLegsVoiceVolume 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.7 unsigned32 read-only
Describs the volume of the voice in dB. AC INI-Param: N/A
                       acAnalogLegsInputGain 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.8 unsigned32 read-only
Describes the Input Gain on the leg in dB. AC INI-Param: N/A
                       acAnalogLegsLegName 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.9 snmpadminstring read-only
Describes the Leg Name as in the Control Protocol. AC INI-Param: N/A
     acAnalogAction 1.3.6.1.4.1.5003.9.10.8.3
         acAnalogFxoAction 1.3.6.1.4.1.5003.9.10.8.3.1
             acAnalogFxoLineTestTable 1.3.6.1.4.1.5003.9.10.8.3.1.1 no-access
                 acAnalogFxoLineTestEntry 1.3.6.1.4.1.5003.9.10.8.3.1.1.1 no-access
                     acAnalogFxoLineTestIndex 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.1 unsigned32 no-access
Index for table use. AC INI-Param: N/A
                     acAnalogFxoLineTestActivate 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.2 integer read-write
Activate line testing in an FXO analog line according to a given line-index. AC INI-Param: N/A Enumeration: 'testFailed': 3, 'runLineTest': 1, 'lineTestDone': 2, 'noTestActivated': 0.
                     acAnalogFxoLineTestHookState 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.3 integer read-only
The hook state of the analog line. AC INI-Param: N/A Enumeration: 'offHookState': 2, 'onHookState': 1.
                     acAnalogFxoLineTestPolarityStatus 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.4 integer read-only
The line's polarity state. AC INI-Param: N/A Enumeration: 'notAvailable': 3, 'normalPolarity': 1, 'reversePolarity': 2.
                     acAnalogFxoLineTestLineConnectionStatus 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.5 integer read-only
The connection's status of the line. AC INI-Param: N/A Enumeration: 'lineConnected': 2, 'lineDisconnected': 1.
                     acAnalogFxoLineTestLineCurrent 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.6 integer32 read-only
The line's current [ma]. AC INI-Param: N/A
                     acAnalogFxoLineTestLineVoltage 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.7 integer32 read-only
The line's voltage [V]. AC INI-Param: N/A
                     acAnalogFxoLineTestRingState 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.8 integer read-only
The Ring's State. AC INI-Param: N/A Enumeration: 'on': 2, 'off': 1.
                     acAnalogFxoLineTestLinePolarity 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.9 integer read-only
The line's polarity state. AC INI-Param: N/A Enumeration: 'positive': 1, 'negative': 2.
                     acAnalogFxoLineTestMwiState 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.10 integer read-only
Mwi's state. AC INI-Param: N/A Enumeration: 'on': 2, 'off': 1.
                     acAnalogFxoLineTestLastCurrentDisconnectDuration 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.11 unsigned32 read-only
Last current disconnect duration in msec. AC INI-Param: N/A
         acAnalogFxsAction 1.3.6.1.4.1.5003.9.10.8.3.2
             acAnalogFxsLineTestTable 1.3.6.1.4.1.5003.9.10.8.3.2.1 no-access
                 acAnalogFxsLineTestEntry 1.3.6.1.4.1.5003.9.10.8.3.2.1.1 no-access
                     acAnalogFxsLineTestIndex 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.1 unsigned32 no-access
Index for table use. AC INI-Param: N/A
                     acAnalogFxsLineTestActivate 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.2 integer read-write
Activate line testing in a FXS analog line according to a given line-index. AC INI-Param: N/A Enumeration: 'testFailed': 3, 'runLineTest': 1, 'lineTestDone': 2, 'noTestActivated': 0.
                     acAnalogFxsLineTestHookState 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.3 integer read-only
The hook state of the analog line. AC INI-Param: N/A Enumeration: 'offHookState': 2, 'onHookState': 1.
                     acAnalogFxsLineTestRingState 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.4 integer read-only
Line's ring state. AC INI-Param: N/A Enumeration: 'offRingState': 1, 'onRingState': 2.
                     acAnalogFxsLineTestPolarityStatus 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.5 integer read-only
Line's reversal-polarity. AC INI-Param: N/A Enumeration: 'normalPolarity': 1, 'reversePolarity': 2.
                     acAnalogFxsLineTestMessageWaitingIndication 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.6 integer read-only
Line's messgae waiting indication state. AC INI-Param: N/A Enumeration: 'noWaitingMessage': 1, 'waitingMessage': 2.
                     acAnalogFxsLineTestLineCurrentReading 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.7 unsigned32 read-only
The Line current reading in 10ua units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. AC INI-Param: N/A
                     acAnalogFxsLineTestLineVoltageReading 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.8 integer32 read-only
The Line voltage reading in 10mV units. In case of MP124 the Line voltage reading in 1V units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. AC INI-Param: N/A
                     acAnalogFxsLineTestAnalogVoltageReading 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.9 unsigned32 read-only
The current analog voltage reading in 10mV units. his test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. AC INI-Param: N/A
                     acAnalogFxsLineTestRingVoltageReading 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.10 integer32 read-only
The current ring voltage reading in 10mV units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. AC INI-Param: N/A
                     acAnalogFxsLineTestLongLineCurrentReading 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.11 unsigned32 read-only
The current long line reading in 10ua units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. AC INI-Param: N/A
         acAnalogCommonAction 1.3.6.1.4.1.5003.9.10.8.3.3
             acAnalogCommonChannelTable 1.3.6.1.4.1.5003.9.10.8.3.3.1 no-access
Table for common channels operations.
                 acAnalogCommonChannelEntry 1.3.6.1.4.1.5003.9.10.8.3.3.1.1 no-access
                     acAnalogCommonChannelIndex 1.3.6.1.4.1.5003.9.10.8.3.3.1.1.1 unsigned32 no-access
Index for table use, the current channel. AC INI-Param: N/A
                     acAnalogCommonChannelAction 1.3.6.1.4.1.5003.9.10.8.3.3.1.1.2 integer read-write
An action to make on the current channel, The Reset action is for Analog channels only. AC INI-Param: N/A Enumeration: 'reset': 1, 'noAction': 0.