A3COM-HUAWEI-MPLSOAM-PS-MIB: View SNMP OID List / Download MIB

VENDOR: 3COM


 Home MIB: A3COM-HUAWEI-MPLSOAM-PS-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 h3cMplsOamPs 1.3.6.1.4.1.43.45.1.10.2.80
This MIB contains objects to configure mpls protect-switch module.
       h3cMplsOamPsScalarGroup 1.3.6.1.4.1.43.45.1.10.2.80.1
           h3cMplsOamPsTrapOpen 1.3.6.1.4.1.43.45.1.10.2.80.1.1 truthvalue read-write
Whether mpls protect-switch trap is globally enabled. false: disable; true: enable
       h3cMplsOamPsTable 1.3.6.1.4.1.43.45.1.10.2.80.2
           h3cMplsPsTable 1.3.6.1.4.1.43.45.1.10.2.80.2.1 no-access
This table specifies per-protection-group MPLS PS capability and associated information.
               h3cMplsPsEntry 1.3.6.1.4.1.43.45.1.10.2.80.2.1.1 no-access
An entry in this table is created by an LSR for every protection group capable of supporting mpls ps.
                   h3cMplsPsIndex 1.3.6.1.4.1.43.45.1.10.2.80.2.1.1.1 integer32 no-access
This is a unique index for an entry in the mplspsEntry.
                   h3cMplsPsGroupID 1.3.6.1.4.1.43.45.1.10.2.80.2.1.1.2 integer32 read-only
This is a unique group id for an entry in the mplspsEntry. One protect-switch group is composed of one working static-lsp and one protection static-lsp.
                   h3cMplsPsWorkLspName 1.3.6.1.4.1.43.45.1.10.2.80.2.1.1.3 octet string read-only
The name of the working static-lsp.
                   h3cMplsPsProtectLspName 1.3.6.1.4.1.43.45.1.10.2.80.2.1.1.4 octet string read-only
The name of the protection static-lsp.
                   h3cMplsPsRevertiveMode 1.3.6.1.4.1.43.45.1.10.2.80.2.1.1.5 integer32 read-only
Revertive mode is a protection switching mode where revertive action (switch back to the working LSP) is taken after the working LSP is repaired. And switching does not occur in a non-revertive mode. 1: revertive; 2: non-revertive;
                   h3cMplsPsWTR 1.3.6.1.4.1.43.45.1.10.2.80.2.1.1.6 integer32 read-only
Wait to Restore timer is only applicable for the revertive mode and applies to a working LSP, it prevents reversion back to select the working LSP until the Wait to Restore timer has expired. The default value is 12 minutes. step is 30s.
                   h3cMplsPsHoldOff 1.3.6.1.4.1.43.45.1.10.2.80.2.1.1.7 integer32 read-only
The time between declaration of signal degrade or signal fail, and the initialization of the protection switching algorithm. Step is 100ms, maximum is 10s.
                   h3cMplsPsSwitchCondition 1.3.6.1.4.1.43.45.1.10.2.80.2.1.1.8 integer32 read-only
The current switch condition of the protection group. 1: clear, this command clears all of the externally initiated switch commands listed below; 2: lockout of protection, fix the selector position on the working LSP, Prevents the selector from switching to the protection LSP when it is selecting the working LSP. Switches the selector from the protection to the working LSP when it is selecting the protection LSP; 3: forced protection, switches the selector from the working LSP to the protection LSP (unless a higher priority switch request (i.e., LoP) is in effect); 4: signal fail, for 1:1, Signal Fail (SF) is declared when the source of the protection domain enters the Defect State by receiving a BDI packet (from the return LSP or out of band). 5: manual switch for working-lsp, switches the selector from the working LSP to the protection LSP (unless an equal or higher priority switch request (i.e., LoP, FS, SF or MS) is in effect); 6: manual switch for protection-lsp, switches the selector from the protection LSP to the working LSP (unless an equal or higher priority switch request (i.e., LoP, FS, SF or MS) is in effect). 7: WTR-timer, a configurable timer which is used to delay before reversion; 8: HoldOff-timer, the time between declaration of signal degrade or signal fail, and the initialization of the protection switching algorithm; 9: Others; The pripority of the commands are: clear > lockout of protection > force switch > manual switch for working lsp = manual switch for protection lsp
                   h3cMplsPsWorkLspDetectState 1.3.6.1.4.1.43.45.1.10.2.80.2.1.1.9 integer32 read-only
The state of working static-lsp state in one protection group, whether it is in defect: 1: it is out of defect; 2: it enters defect.
                   h3cMplsPsWorkLspUpDownState 1.3.6.1.4.1.43.45.1.10.2.80.2.1.1.10 integer32 read-only
The state of working static-lsp state in one protection group, whether it is up or down: 1: it is in up state; 2: it is in down state.
                   h3cMplsPsProtLspDetectState 1.3.6.1.4.1.43.45.1.10.2.80.2.1.1.11 integer32 read-only
The state of protection static-lsp state in one protection group, whether it is in detection: 1: it is out of defect; 2: it enters defect.
                   h3cMplsPsProtLspUpDownState 1.3.6.1.4.1.43.45.1.10.2.80.2.1.1.12 integer32 read-only
The state of protection static-lsp state in one protection group, whether it is up or down: 1: it is in up state; 2: it is in down state.
                   h3cMplsPsSwitchResult 1.3.6.1.4.1.43.45.1.10.2.80.2.1.1.13 integer32 read-only
Which tunnel is used to transfer the data stream. 1: working static-lsp; 2: protection static-lsp.
                   h3cMplsPsRowStatus 1.3.6.1.4.1.43.45.1.10.2.80.2.1.1.14 rowstatus read-only
This object is responsible for managing the creation, deletion and modification of rows, which support active status and CreatAndGo, destroy operation. To create a new row, h3cMplsPsGroupID, h3cMplsPsWorkLspName, h3cMplsPsProtectLspName, h3cMplsPsRevertiveMode, h3cMplsPsWTR and h3cMplsPsHoldOff must be specified.
       h3cMplsOamPsNotifications 1.3.6.1.4.1.43.45.1.10.2.80.3
           h3cMplsPsSwitchPtoW 1.3.6.1.4.1.43.45.1.10.2.80.3.1
This notification is generated when switching from protection-lsp to working-lsp occured.
           h3cMplsPsSwitchWtoP 1.3.6.1.4.1.43.45.1.10.2.80.3.2
This notification is generated when switching from woking-lsp to protection-lsp occured.